Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Georgian Med News ; (348): 54-56, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38807391

ABSTRACT

The use of tourniquet is common in orthopaedic surgeries as it reduces blood loss, enhances visualization of the operating field, and leads to quicker procedures. However, the use of tourniquet has certain risks which can be avoided by following guidelines like British Orthopaedic Association Standards for Trauma (BOAST) guidelines for safe use of tourniquet. This audit study was done in a District general hospital to check the compliance of two trauma theatres with BOAST guidelines. The audit found that there was poor documentation of tourniquet details in the operation notes (10%). Regarding tourniquet time and pressure, the compliance in the two theatres was 95 % & 97.5 %. The recommendations of this audit were to use a template to improve documentation of tourniquet details in the operation notes and training of theatre staff on BOAST guidelines for safe use of tourniquet.


Subject(s)
Hospitals, District , Medical Audit , Orthopedic Procedures , Tourniquets , Humans , Orthopedic Procedures/adverse effects , United Kingdom , Operating Rooms/standards , Guideline Adherence/statistics & numerical data , Blood Loss, Surgical/prevention & control
2.
Georgian Med News ; (348): 91-93, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38807399

ABSTRACT

The restoration of the joint line is important for a good functional outcome after a Total Knee Arthroplasty(TKA). Knee joint biomechanics need to be restored as near normal as possible. Joint line elevation leads to anterior knee pain, decrease in range of motion, patella baja ,mid-flexion instability and impingement of patellar tendon. Joint line depression on the other hand leads to patella alta, risk of patellar subluxation and mid-flexion instability of the knee. Various studies have demonstrated various range of acceptable joint line variation but there is no clear acceptable range of joint line variation. More studies are required for establishing the acceptable range of joint line variation and standard practices should be established for arthroplasty surgeons for preventing variation of joint line.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Joint , Range of Motion, Articular , Humans , Range of Motion, Articular/physiology , Knee Joint/surgery , Knee Joint/physiopathology , Biomechanical Phenomena , Patella/surgery , Joint Instability/surgery , Joint Instability/physiopathology
3.
Georgian Med News ; (347): 122-124, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38609127

ABSTRACT

Fractures of the metacarpal particularly the 5th metacarpal is quite common among all hand fractures and has a high incidence in male adult population. Proper management of these fractures plays a key role in rehabilitation and early return to work thus reducing the economic burden. Treatment of these injuries depends on the type of injury: whether it is a closed/open fracture, degree of angulation at the fracture site and also mal-rotation and shortening of the finger. Non-operative management is suitable for fractures which are closed, non-displaced and without angulation or rotation. Open fractures, fractures with angulation and/or mal-rotation and fractures with neuro-vascular injury are more suitable for operative management. The acceptable angulation for conservative management for most studies is 70 degrees. Buddy strapping with a Futura splint provides good functional results. In fractures requiring operative intervention, K-wire fixation is a minimally invasive method of fixation, which in most cases has good functional results. Plate and screw fixation, however, is preferred for cases with significant comminution or multiple metacarpal fractures.


Subject(s)
Fractures, Closed , Fractures, Open , Adult , Humans , Male , Bone Screws , Conservative Treatment
4.
Georgian Med News ; (347): 149-150, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38609132

ABSTRACT

Traditionally, it was believed that both proximal and distal locking are essential for achieving stability during intra-medullary fixation for extra-capsular hip fractures. However, recent literature has presented varying perspectives on the necessity of distal locking. Distal locking plays a significant role in managing hip fractures with uncertainties regarding longitudinal and rotational stability. This includes cases of comminuted intertrochanteric fractures with subtrochanteric extension, reverse oblique and high oblique fractures, broad medullary canals, comminution of the lateral wall, diaphyseal fractures, and large posteromedial fragments extending below the level of the lesser trochanter. In stable pertrochanteric fractures, with the lag screw passing through the lateral cortex of the distal fragment, may not require a distal locking screw. Distal locking has been associated with potential complications, including irritation of the fascia lata, prolonged operation time, increased radiation exposure, greater blood loss, implant loosening, secondary femoral stress fractures, and damage to the femoral artery. Thus, although distal locking is of doubtful significance in stable pertrochanteric fractures it is essential in unstable fracture patterns.


Subject(s)
Femoral Fractures , Fracture Fixation, Intramedullary , Hip Fractures , Humans , Hip Fractures/diagnostic imaging , Hip Fractures/surgery , Bone Screws , Femoral Artery
SELECTION OF CITATIONS
SEARCH DETAIL
...