1.
J Virol Methods ; 311: 114627, 2023 01.
Article in English | MEDLINE | ID: mdl-36191664

ABSTRACT

Elephant endotheliotropic herpesvirus (EEHV) is the causative agent of EEHV-hemorrhagic disease (EEHV-HD) in elephants worldwide. This disease is highly virulent and a predominant cause of fatalities in young Asian elephants. Rapid diagnosis and aggressive therapies have been determined to be a key strategy in the successful treatment of this disease. Herein, we have developed the immunochromatographic strip test for EEHV detection. Accordingly, 31.2 kDa of partial EEHV DNA polymerase (DNApol) protein was expressed in Escherichia coli and used to generate rabbit polyclonal anti-EEHV DNApol antibodies. These were then used to develop an ICS test for EEHV antigen detection using the double-antibody sandwich colloidal gold method. Anti-EEHV DNApol antibodies conjugated with 40 nm colloidal gold solution were used as a detector, while rabbit anti-EEHV DNApol and goat anti-rabbit IgG antibodies immobilized on the nitrocellulose membrane were used as the test and control lines, respectively. The test had a detection limit of 1.25 × 105 viral genome copies (vgc)/mL of EEHV obtained from blood samples. Moreover, no specialized equipment or laboratory infrastructure was required in the administration of this test. This developed ICS test for EEHV antigen detection can be used in field application for the rapid detection of EEHV in resource-limited environments.


Subject(s)
Elephants , Herpesviridae Infections , Herpesviridae , Animals , Rabbits , Herpesviridae/genetics , Herpesviridae Infections/diagnosis , Herpesviridae Infections/veterinary , Antigens, Viral , Gold Colloid
2.
Diagnostics (Basel) ; 12(1)2022 Jan 06.
Article in English | MEDLINE | ID: mdl-35054302

ABSTRACT

A point-of-care diagnostic for early and rapid diagnosis of scrub typhus caused by Orientia tsutsugamushi is required for prompt and proper treatment of patients presenting with undifferentiated febrile illnesses. In this study, an immunochromatographic antigen detection test kit (ICT AgTK) that targets the highly conserved O. tsutsugamushi 60 kDa GroEL chaperonin (heat shock protein 60) was developed. E. coli-derived recombinant GroEL expressed from DNA coding for the consensus sequence of 32 GroEL gene sequences extracted from the GenBank database was used to immunize rabbits and mice. Rabbit polyclonal antibodies (pAb) were used for preparing a gold-pAb conjugate, and the rGroEL-specific mouse monoclonal antibody was used as the antigen detection reagent at the ICT test line. In-house validation revealed that the ICT AgTK gave 85, 100 and 95% diagnostic sensitivity, specificity and accuracy, respectively, compared to the combined clinical features and standard IFA when tested on 40 frozen serum samples. The test kits correctly identified 10 scrub typhus samples out of 15 fresh plasma/buffy coat samples of patients with febrile illnesses. For independent laboratory validation, the ICT AgTK was sent to one provincial hospital. The ICT AgTK utilized by the hospital medical technologist correctly identified six scrub typhus samples out of 20 serum samples of patients with fever, as confirmed by specific IgM/IgG detection by IFA. The ICT AgTK is easy to perform with rapid turn-around time. It has the potential to be used as an important tool for on-site and early scrub typhus diagnosis by allowing testing of freshly collected samples (serum, plasma or buffy coat), especially in resource-limited healthcare settings.

3.
Diagnostics (Basel) ; 11(5)2021 Apr 23.
Article in English | MEDLINE | ID: mdl-33922698

ABSTRACT

The aim of this study was to develop a novel lateral flow immunochromatoghaphic strip test (ICT) for detecting cryptococcal polysaccharide capsular antigens using only a single specific monoclonal antibody, mAb 18B7. The mAb 18B7 is a well characterized antibody that specifically binds repeating epitopes displayed on the cryptococcal polysaccharide glucuronoxylomannan (GXM). We validated the immunoreactivities of mAb 18B7 against capsular antigens of different cryptococcal serotypes. The mAb 18B7 ICT was constructed as a sandwich ICT strip and the antibody serving in the mobile phase (colloidal gold conjugated mAb 18B7) to bind one of the GXM epitopes while the stationary phase antibody (immobilized mAb18B7 on test line) binding to other remaining unoccupied epitopes to generate a positive visual readout. The lower limit of detection of capsular antigens for each of the Cryptococcus serotypes tested was 0.63 ng/mL. No cross-reaction was found against a panel of antigens isolated from cultures of other pathogenic fungal, except the crude antigen of Trichosporon sp. with the lower limit of detection of 500 ng/mL (~800 times higher than that for cryptococcal GXM). The performance of the mAb 18B7 ICT strip was studied using cerebrospinal fluid (CSF) and serum and compared to commercial diagnostic kits (latex agglutination CALAS and CrAg IMMY). The sensitivity, specificity and accuracy of the mAb18B7 ICT with CSF from patients with confirmed cryptococcal meningitis were 92.86%, 100% and 96.23%, respectively. No false positives were observed with samples from non-cryptococcosis patients. With serum samples, the mAb 18B7 ICT gave a sensitivity, specificity and accuracy of 96.15%, 97.78% and 96.91%, respectively. Our results show that the mAb 18B7 based ICT was reliable, reproducible, and cost-effective as a point-of-care immunodiagnostic test for cryptococcosis. The mAb 18B7 ICT may be particularly useful in countries where commercial kits are not available or affordable.

4.
Asian Pac J Allergy Immunol ; 36(1): 8-15, 2018 Mar.
Article in English | MEDLINE | ID: mdl-28577523

ABSTRACT

BACKGROUND: Avoidance of allergen exposure is an effective measure for preventing naÏve and allergic individuals from sensitization (primary intervention) and disease aggravation (secondary intervention), respectively. Regular monitoring of the allergens in the environment is required for the effective intervention. Thus, there is a need for cost-effective test kits for environmental allergen quantifications. OBJECTIVE: To invent a test kit for quantification of cat major allergen, Fel d 1. METHODS: A mouse monoclonal antibody (MAb) specific to the newly identified IgE-binding conformational epitope of the cat major allergen (Fel d 1) and rabbit polyclonal IgG to recombinant Fel d 1 were used as allergen capture and detection reagents, respectively. Native Fel d 1 was used in constructing a standard curve. RESULTS AND CONCLUSION: Sixteen of 36 dust samples collected from houses of cat allergic subjects in Bangkok contained Fel d 1 above 0.29 µg/gram of dust which is considered as a novel threshold level for causing cat allergy sensitization or symptoms. Among them, 7 samples contained the allergen exceeding 2.35 µg/gram of dust which is the level that would aggravate asthma. Results of the allergen quantification using the locally made test kit showed strong correlation (r = 0.923) with the allergen quantification using commercialized reagents. The assay using MAb to Fel d 1 IgE-binding epitope of this study has potential application as an economic and practical tool for cat allergy intervention measure especially in localities where health resources are relatively limited.


Subject(s)
Allergens/analysis , Antibodies, Monoclonal , Dust/analysis , Glycoproteins/analysis , Hypersensitivity/immunology , Allergens/immunology , Animals , Cats , Epitopes/immunology , Glycoproteins/immunology , Humans , Immunoglobulin E/immunology , Mice , Tandem Mass Spectrometry
5.
PeerJ ; 5: e3431, 2017.
Article in English | MEDLINE | ID: mdl-28626609

ABSTRACT

Subclinical mastitis is a persistent problem in dairy farms worldwide. Environmental Escherichia coli is the bacterium predominantly responsible for this condition. In Thailand, subclinical mastitis in dairy cows is usually treated with various antibiotics, which could lead to antibiotic resistance in bacteria. E. coli is also a reservoir of many antibiotic resistance genes, which can be conveyed to other bacteria. In this study, the presence of E. coli in milk and water samples was reported, among which enteropathogenic E. coli was predominant, followed by enteroaggregative E. coli and enterohemorrhagic E. coli, which was found only in milk samples. Twenty-one patterns of antibiotic resistance were identified in this study. Ampicillin- and carbenicillin-resistant E. coli was the most common among the bacterial isolates from water samples. Meanwhile, resistance to ampicillin, carbenicillin, and sulfamethoxazole-trimethoprim was the pattern found most commonly in the E. coli from milk samples. Notably, only the E. coli from water samples possessed ESBL phenotype and carried antibiotic resistance genes, blaTEM and blaCMY-2. This indicates that pathogenic E. coli in dairy farms is also exposed to antibiotics and could potentially transfer these genes to other pathogenic bacteria under certain conditions.