Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 15 de 15
Filter
Add more filters










Publication year range
1.
Materials (Basel) ; 14(10)2021 May 20.
Article in English | MEDLINE | ID: mdl-34065486

ABSTRACT

The high-temperature conductivity of the perovskite oxides of a La4BaCu5O13+δ (LBCO) thin film prepared by RF sputtering deposition and thermal annealing has been studied. While the bulk LBCO compound was metallic, the LBCO film deposited on a Si substrate by sputtering and a post annealing process showed semiconductor-like conduction, which is considered to be due to the defects and poor grain connectivity in the LBCO film on the Si substrate. The LBCO film deposited on a SrTiO3 substrate was of high film quality and showed metallic conduction. When the cation site Cu was substituted by Co, the electrical conductivity of the LBCO film increased further and its temperature dependence became smaller. The transport properties of LBCO films are investigated to understand its carrier generation mechanism.

2.
Sensors (Basel) ; 20(9)2020 May 08.
Article in English | MEDLINE | ID: mdl-32397213

ABSTRACT

We investigated the selective detection of target volatile organic compounds (VOCs) which are age-related body odors (namely, 2-nonenal, pelargonic acid, and diacetyl) and a fungal odor (namely, acetic acid) in the presence of interference VOCs from car interiors (namely, n-decane, and butyl acetate). We used eight semiconductive gas sensors as a sensor array; analyzing their signals using machine learning; principal-component analysis (PCA), and linear-discriminant analysis (LDA) as dimensionality-reduction methods; k-nearest-neighbor (kNN) classification to evaluate the accuracy of target-gas determination; and random forest and ReliefF feature selections to choose appropriate sensors from our sensor array. PCA and LDA scores from the sensor responses to each target gas with contaminant gases were generally within the area of each target gas; hence; discrimination between each target gas was nearly achieved. Random forest and ReliefF efficiently reduced the required number of sensors, and kNN verified the quality of target-gas discrimination by each sensor set.

3.
J Breath Res ; 14(1): 016003, 2019 10 21.
Article in English | MEDLINE | ID: mdl-31292283

ABSTRACT

In this study the correlation between the condition of drivers and their expiration was evaluated by analyzing the exhalation of car drivers in a simulation setting using a spirometer and a volatile organic compound (VOC) gas sensor. Participants wore exhalation masks and their expiration was monitored for fluctuations in breath measurements, including VOC concentration, oxygen intake, carbon dioxide excretion, and respiration rate. Participants used a driving simulator on four different courses of varying difficulty for approximately five min each, with the mean and standard deviation (SD) being calculated for each parameter during the cruising section of the course. After driving each course, participants assessed the 'enjoyment' and 'difficulty' of their experience. It was verified whether the state of the participants during driving can be determined from exhalation by comparing the questionnaire results. The mean and SD of all exhalation parameters were analyzed using box-and-whisker plots and any statistical significance between these parameters and driver experience was tested using the analysis of variance. There was no significant difference in the correlation between the questionnaire result of 'difficulty' and each exhalation parameter. By contrast, the low assessment group of 'enjoyment' showed large SDs in all parameters from both the VOC gas sensor and spirometer.


Subject(s)
Automobile Driving , Breath Tests/methods , Spirometry/instrumentation , Volatile Organic Compounds/analysis , Adult , Analysis of Variance , Exhalation , Female , Humans , Male , Middle Aged , Young Adult
4.
Sensors (Basel) ; 18(5)2018 May 16.
Article in English | MEDLINE | ID: mdl-29772659

ABSTRACT

Inflammable breath gases such as H2 and CH4 are used as bio markers for monitoring the condition of the colon. However, their typical concentrations of below 100 ppm pose sensitivity and selectivity challenges to current gas sensing systems without the use of chromatography. We fabricated a compact, gas-selective thermoelectric array sensor (TAS) that uses micro-machined sensor devices with three different combustion catalysts to detect gases such as H2, CO, and CH4 in breath. Using Pt/Pt-W thin-film micro-heater meanders, Pd/Al2O3, Pt,Pd,Au/Co3O4, and Pt/Al2O3 catalysts were heated to 320, 200, and 125 °C, respectively, and the gas sensing performances of the TAS for each gas and for a model breath gas mixture of 100 ppm H2, 25 ppm CO, 50 ppm CH4, and 199 ppm CO2 in air were investigated. Owing to its high catalyst temperature, the Pd/Al2O3 catalyst burned all three gases, while the Pt,Pd,Au/Co3O4 burned CO and H2 and the Pt/Al2O3 burned H2 selectively. To calibrate the gas concentration of the mixture gas without the use of a gas separation tool, linear discriminant analysis was applied to measure the sensing performance of TAS. To enhance the gas selectivity against H2, a double catalyst structure was integrated into the TAS sensor.


Subject(s)
Breath Tests , Gases/analysis , Micro-Electrical-Mechanical Systems/instrumentation , Aluminum Oxide/chemistry , Catalysis , Gases/chemistry , Humans , Platinum/chemistry , Respiration , Temperature
5.
Sensors (Basel) ; 17(2)2017 Feb 04.
Article in English | MEDLINE | ID: mdl-28165388

ABSTRACT

Monitoring exhaled breath is a very attractive, noninvasive screening technique for early diagnosis of diseases, especially lung cancer. However, the technique provides insufficient accuracy because the exhaled air has many crucial volatile organic compounds (VOCs) at very low concentrations (ppb level). We analyzed the breath exhaled by lung cancer patients and healthy subjects (controls) using gas chromatography/mass spectrometry (GC/MS), and performed a subsequent statistical analysis to diagnose lung cancer based on the combination of multiple lung cancer-related VOCs. We detected 68 VOCs as marker species using GC/MS analysis. We reduced the number of VOCs and used support vector machine (SVM) algorithm to classify the samples. We observed that a combination of five VOCs (CHN, methanol, CH3CN, isoprene, 1-propanol) is sufficient for 89.0% screening accuracy, and hence, it can be used for the design and development of a desktop GC-sensor analysis system for lung cancer.


Subject(s)
Lung Neoplasms , Algorithms , Breath Tests , Exhalation , Gas Chromatography-Mass Spectrometry , Humans , Support Vector Machine , Volatile Organic Compounds
6.
Sensors (Basel) ; 17(1)2017 Jan 05.
Article in English | MEDLINE | ID: mdl-28067788

ABSTRACT

Mixed-potential gas sensors with a proton conductor consisting of zinc metaphosphate glass and benzimidazole were fabricated for the detection of hydrogen produced by intestinal bacteria in dry and humid air. The gas sensor consisting of an alumina substrate with platinum and gold electrodes showed good response to different hydrogen concentrations from 250 parts per million (ppm) to 25,000 ppm in dry and humid air at 100-130 °C. The sensor response varied linearly with the hydrogen and carbon monoxide concentrations due to mass transport limitations. The sensor responses to hydrogen gas (e.g., -0.613 mV to 1000 ppm H2) was higher than those to carbon monoxide gas (e.g., -0.128 mV to 1000 ppm CO) at 120 °C under atmosphere with the same level of humidity as expired air.

7.
Sensors (Basel) ; 16(11)2016 Nov 10.
Article in English | MEDLINE | ID: mdl-27834896

ABSTRACT

Various volatile organic compounds (VOCs) in breath exhaled by patients with lung cancer, healthy controls, and patients with lung cancer who underwent surgery for resection of cancer were analyzed by gas condenser-equipped gas chromatography-mass spectrometry (GC/MS) for development of an exhaled breath monitoring prototype system involving metal oxide gas sensors, a gas condenser, and gas chromatography columns. The gas condenser-GC/MS analysis identified concentrations of 56 VOCs in the breath exhaled by the test population of 136 volunteers (107 patients with lung cancer and 29 controls), and selected four target VOCs, nonanal, acetoin, acetic acid, and propanoic acid, for use with the condenser, GC, and sensor-type prototype system. The prototype system analyzed exhaled breath samples from 101 volunteers (74 patients with lung cancer and 27 controls). The prototype system exhibited a level of performance similar to that of the gas condenser-GC/MS system for breath analysis.


Subject(s)
Biosensing Techniques/methods , Breath Tests/methods , Gas Chromatography-Mass Spectrometry/methods , Lung Neoplasms/metabolism , Adult , Female , Humans , Male , Middle Aged , Volatile Organic Compounds/analysis
8.
Sensors (Basel) ; 15(12): 31687-98, 2015 Dec 15.
Article in English | MEDLINE | ID: mdl-26694397

ABSTRACT

The CO sensing properties of a micro thermoelectric gas sensor (micro-TGS) with a double AuPtPd/SnO2 and Pt/α-Al2O3 catalyst were investigated. While several nanometer sized Pt and Pd particles were uniformly dispersed on SnO2, the Au particles were aggregated as particles measuring >10 nm in diameter. In situ diffuse reflectance Fourier transform Infrared spectroscopy (DRIFT) analysis of the catalyst showed a CO adsorption peak on Pt and Pd, but no clear peak corresponding to the interaction between CO and Au was detected. Up to 200 °C, CO combustion was more temperature dependent than that of H2, while H2 combustion was activated by repeated exposure to H2 gas during the periodic gas test. Selective CO sensing of the micro-TGS against H2 was attempted using a double catalyst structure with 0.3-30 wt% Pt/α-Al2O3 as a counterpart combustion catalyst. The sensor output of the micro-TGS decreased with increasing Pt content in the Pt/α-Al2O3 catalyst, by cancelling out the combustion heat from the AuPtPd/SnO2 catalyst. In addition, the AuPtPd/SnO2 and 0.3 wt% Pt/α-Al2O3 double catalyst sensor showed good and selective CO detection. We therefore demonstrated that our micro-TGS with double catalyst structure is useful for controlling the gas selectivity of CO against H2.


Subject(s)
Carbon Monoxide/analysis , Chemistry Techniques, Analytical/instrumentation , Metals, Heavy/chemistry , Tin Compounds/chemistry , Chemistry Techniques, Analytical/methods , Equipment Design , Hot Temperature , Hydrogen/analysis , Methane/analysis
9.
Sensors (Basel) ; 15(4): 9427-37, 2015 Apr 21.
Article in English | MEDLINE | ID: mdl-25905705

ABSTRACT

We have investigated the catalytic layer in zirconium-doped cerium oxide, Ce0.9Zr0.1O2 (CeZr10) resistive oxygen sensors for reducing the effects of flammable gases, namely hydrogen and carbon monoxide. When the concentration of flammable gases is comparable to that of oxygen, the resistance of CeZr10 is affected by the presence of these gases. We have developed layered thick films, which consist of an oxygen sensor layer (CeZr10), an insulation layer (Al2O3), and a catalytic layer consisting of CeZr10 with 3 wt% added platinum, which was prepared via the screen printing method. The Pt-CeZr10 catalytic layer was found to prevent the detrimental effects of the flammable gases on the resistance of the sensor layer. This effect is due to the catalytic layer promoting the oxidation of hydrogen and carbon monoxide through the consumption of ambient O2 and/or the lattice oxygen atoms of the Pt-CeZr10 catalytic layer.

10.
Sensors (Basel) ; 15(4): 8109-20, 2015 Apr 07.
Article in English | MEDLINE | ID: mdl-25853408

ABSTRACT

We prepared 0.1 wt%-30 wt% Pd-loaded Co3O4 by a colloidal mixing method and investigated the sensing properties of a Pd-loaded Co3O4 sensor element, such as the sensor response, 90% response time, 90% recovery time, and signal-to-noise (S/N) ratio, toward low nitric oxide (NO) gas levels in the range from 50 to 200 parts per billion. The structural properties of the Pd-loaded Co3O4 powder were investigated using X-ray diffraction analysis and transmission electron microscopy. Pd in the powder existed as PdO. The sensor elements with 0.1 wt%-10 wt% Pd content have higher sensor properties than those without any Pd content. The response of the sensor element with a 30 wt% Pd content decreased markedly because of the aggregation and poor dispersibility of the PdO particles. High sensor response and S/N ratio toward the NO gas were achieved when a sensor element with 10 wt% Pd content was used.


Subject(s)
Cobalt/chemistry , Nitric Oxide/chemistry , Oxides/chemistry , Palladium/chemistry , X-Ray Diffraction
11.
Materials (Basel) ; 8(7): 3992-4003, 2015 Jul 02.
Article in English | MEDLINE | ID: mdl-28793420

ABSTRACT

To provide a convenient and practical synthesis process for metal ion doping on the surface of nanoparticles in an assembled nanostructure, core-shell-structured La-doped SrTiO3 nanocubes with a Nb-doped surface layer were synthesized via a rapid synthesis combining a rapid sol-precipitation and hydrothermal process. The La-doped SrTiO3 nanocubes were formed at room temperature by a rapid dissolution of NaOH pellets during the rapid sol-precipitation process, and the Nb-doped surface (shell) along with Nb-rich edges formed on the core nanocubes via the hydrothermal process. The formation mechanism of the core-shell-structured nanocubes and their shape evolution as a function of the Nb doping level were investigated. The synthesized core-shell-structured nanocubes could be arranged face-to-face on a SiO2/Si substrate by a slow evaporation process, and this nanostructured 10 µm thick thin film showed a smooth surface.

12.
Sensors (Basel) ; 14(5): 8350-62, 2014 May 09.
Article in English | MEDLINE | ID: mdl-24818660

ABSTRACT

A novel miniaturized calorimeter-type sensor device with a dual-catalyst structure was fabricated by integrating different catalysts on the hot (Pd/θ-Al2O3) and cold (Pt/α-Al2O3) ends of the device. The device comprises a calorimeter with a thermoelectric gas sensor (calorimetric-TGS), combining catalytic combustion and thermoelectric technologies. Its response for a model fuel gas of hydrogen and methane was investigated with various combustor catalyst compositions. The calorimetric-TGS devices detected H2, CH4, and a mixture of the two with concentrations ranging between 200 and 2000 ppm at temperatures of 100-400 °C, in terms of the calorie content of the gases. It was necessary to reduce the much higher response voltage of the TGS to H2 compared to CH4. We enhanced the H2 combustion on the cold side so that the temperature differences and response voltages to H2 were reduced. The device response to H2 combustion was reduced by 50% by controlling the Pt concentration in the Pt/α-Al2O3 catalyst on the cold side to 3 wt%.


Subject(s)
Calorimetry/instrumentation , Electric Power Supplies , Heating/instrumentation , Hydrogen/analysis , Methane/analysis , Thermography/instrumentation , Transducers , Complex Mixtures/analysis , Equipment Design , Equipment Failure Analysis
13.
Sensors (Basel) ; 14(1): 1822-34, 2014 Jan 21.
Article in English | MEDLINE | ID: mdl-24451468

ABSTRACT

A thermoelectric gas sensor (TGS) with a combustion catalyst is a calorimetric sensor that changes the small heat of catalytic combustion into a signal voltage. We analyzed the thermal balance of a TGS to quantitatively estimate the sensor parameters. The voltage signal of a TGS was simulated, and the heat balance was calculated at two sections across the thermoelectric film of a TGS. The thermal resistances in the two sections were estimated from the thermal time constants of the experimental signal curves of the TGS. The catalytic combustion heat Q(catalyst) required for 1 mV of ∆V(gas) was calculated to be 46.1 µW. Using these parameters, we find from simulations for the device performance that the expected Q(catalyst) for 200 and 1,000 ppm H2 was 3.69 µW and 11.7 µW, respectively.

14.
Sensors (Basel) ; 13(9): 12467-81, 2013 Sep 17.
Article in English | MEDLINE | ID: mdl-24048338

ABSTRACT

Semiconductor-based gas sensors that use n-type WO3 or p-type Co3O4 powder were fabricated and their gas sensing properties toward NO2 or NO (0.5-5 ppm in air) were investigated at 100 °C or 200 °C. The resistance of the WO3-based sensor increased on exposure to NO2 and NO. On the other hand, the resistance of the Co3O4-based sensor varied depending on the operating temperature and the gas species. The chemical states of the surface of WO3 or those of the Co3O4 powder on exposure to 1 ppm NO2 and NO were investigated by diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy. No clear differences between the chemical states of the metal oxide surface exposed to NO2 or NO could be detected from the DRIFT spectra.


Subject(s)
Cobalt/chemistry , Conductometry/instrumentation , Gases/analysis , Nitrogen Oxides/analysis , Oxides/chemistry , Semiconductors , Transducers , Tungsten/chemistry , Equipment Design , Equipment Failure Analysis , Nitrogen Oxides/chemistry
15.
Sensors (Basel) ; 13(3): 3252-61, 2013 Mar 08.
Article in English | MEDLINE | ID: mdl-23529123

ABSTRACT

Various types of CO sensors based on cerium oxide (ceria) have been reported recently. It has also been reported that the response speed of CO sensors fabricated from porous ceria thick films comprising nanoparticles is extremely high. However, the response value of such sensors is not suitably high. In this study, we investigated methods of improving the response values of CO sensors based on ceria and prepared gas sensors from core-shell ceria polymer hybrid nanoparticles. These hybrid nanoparticles have been reported to have a unique structure: The core consists of a cluster of ceria crystallites several nanometers in size. We compared the characteristics of the sensors based on thick films prepared from core-shell nanoparticles with those of sensors based on thick films prepared from conventionally used precipitated nanoparticles. The sensors prepared from the core-shell nanoparticles exhibited a resistance that was ten times greater than that of the sensors prepared from the precipitated nanoparticles. The response values of the gas sensors based on the core-shell nanoparticles also was higher than that of the sensors based on the precipitated nanoparticles. Finally, improvements in sensor response were also noticed after the addition of Au nanoparticles to the thick films used to fabricate the two types of sensors.


Subject(s)
Carbon Monoxide/isolation & purification , Cerium/chemistry , Metal Nanoparticles/chemistry , Nanotechnology , Gold/chemistry , Particle Size , Porosity
SELECTION OF CITATIONS
SEARCH DETAIL
...