Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Photobiomodul Photomed Laser Surg ; 39(5): 321-333, 2021 May.
Article in English | MEDLINE | ID: mdl-33275497

ABSTRACT

Purpose: This review article tries to answer this question: "What are the effects of laser surface treatment of fiber posts (FPs), compared with other surface roughening methods, on bond strength of cemented FPs?" Methods: Search was carried out in six electronic databases by focusing on defined key words. Related titles and abstracts, up to March 2019, were collected, read, and selected for quality assessments. A total of 2408 articles were included in the study at the initial stage of the searching phase. Results: Finally, seven studies were recognized to be reliable to be reviewed and meta data analysis in the study. All the studies were in vitro with a total of 340 samples. None of the Er:YAG (-0.27, 95% CI: -2.29 to 1.76; p = 0.79) and Er,Cr:YSGG (-0.04, 95% CI: -1.43 to 1.35; p = 0.95) treated samples showed any significant overall mean differences in final push-out bond strength (PBS) compared with the control groups. Conclusions: Laser pretreatment of FP surfaces might not be effective in providing high PBS. FP surface are susceptible to damage of high-level laser irradiation and might show decreased bond strength.


Subject(s)
Lasers, Solid-State , Post and Core Technique , Materials Testing
2.
Iran Endod J ; 12(2): 173-178, 2017.
Article in English | MEDLINE | ID: mdl-28512481

ABSTRACT

INTRODUCTION: The aim of this in vitro study was to evaluate the correlation between accuracy of Root ZX electronic foramen locator and root canal curvature. METHODS AND MATERIALS: One hundred and ten extracted mandibular molars were selected. Access cavity was prepared and coronal enlargement of mesiobuccal canal was performed. A #10 Flexofile was inserted into the mesiobuccal canal, and a radiography was taken to measure the degree of curvature by Schneider's method. The actual working length (AWL) was defined by inserting the file until its tip could be observed at a place tangential to the major apical foramen and then 0.5 mm was subtracted from this measurement. For the electronic working length (EWL) measurement, the apical 3 or 4 mm of the root was embedded in alginate as the electrolyte material. The file was inserted into the root canal to the major foramen, until the APEX reading was shown on the electronic device and then pulled back until the visual display showed the 0.5-mm mark. The AWL was subtracted from the EWL to define the distance between the file tip and the point 0.5 mm coronal to the major apical foramen. Data were analyzed using the Pearson's correlation coefficient. RESULTS: The accuracy of Root ZX within ±0.1 mm and ±0.5 mm was 38.2% and 94.6%, respectively. There was no correlation between the distance from the EWL to the AWL and the degree of root canal curvature (r=0.097, P=0.317). CONCLUSION: Root canal curvature did not influence the accuracy of Root ZX foramen locator.

SELECTION OF CITATIONS
SEARCH DETAIL
...