Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Transplant Direct ; 8(8): e1350, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35923811

ABSTRACT

Background: Persistent ascites after orthotropic liver transplantation has numerous causes and can be challenging to manage. This study aimed to determine the outcomes associated with conservative and endovascular intervention of posttransplant ascites after deceased donor liver transplantation. Methods: Adult (≥18 y) liver transplant recipients (between 2006 and 2019) who underwent hepatic venous pressure studies to investigate posttransplant ascites were included in this retrospective study. Comparisons were made between those who were managed with conservative therapy versus endovascular intervention and were also based on hepatic venous wedge pressure gradient (normal [≤10 mm Hg] versus elevated [>10 mm Hg]). Results: A total of 30 patients underwent hepatic venography to investigate ascites during the study period. The median time from transplant to venography was 70 d. At least 1 endovascular intervention was performed in 18 of 30 patients (62%), and 12 of 30 patients (38%) were managed conservatively. Endovascular interventions included angioplasty (n = 4), hepatic vein stenting (n = 9), or a transjugular intrahepatic portosystemic shunt (n = 7). The mean (range) hepatic venous wedge pressure gradient for the conservative and endovascular intervention groups was 12 mm Hg (3-23) and14 mm Hg (2-35), respectively. At a 6-mo follow-up, ascites resolved in 6 of 12 patients (50%) and 11 of 18 patients (61%) in the medical management and endovascular groups, respectively. The graft survival rates at 6 and 12 mo were (7/12 [58%] versus 17/18 [94%], P = 0.02) and (7/12 [58%] versus 14/18 [78%], P = 0.25), respectively. Conclusions: Despite medical or endovascular intervention, resolution of ascites is achieved in <60% of patients with persistent ascites. Biopsy findings and venographic pressure studies should be carefully integrated into the management of posttransplant ascites.

2.
Obes Surg ; 31(2): 612-616, 2021 02.
Article in English | MEDLINE | ID: mdl-33025538

ABSTRACT

BACKGROUND: The presentation of leak after laparoscopic sleeve gastrectomy (LSG) is variable. A missed or delayed diagnosis can lead to severe consequences. This study presents our experience: the clinical presentations, laboratory, and radiological findings in patients with leak after LSG. METHODS: A retrospective review of patients who were diagnosed and treated as leak after LSG at our center (January 2012-November 2019). RESULTS: Eighty patients developed leak: 68 (85%) after primary LSG, 6 (7.5%) after Re-LSG and 6 (7.5%) after band removal to revisional LSG. Mean age 35.9 ± 10 years. The diagnosis was within 18 ± 14 days after surgery. Five (6.3%) patients were diagnosed during the same admission. Only 29.3% of patients were diagnosed correctly from the first visit to the ER. Most were misdiagnosed as gastritis (49%) and pneumonia (22.6%). Thirty-four patients (45.3%) were diagnosed correctly at the third visit. The most common presenting symptoms were abdominal pain (90%), tachycardia (71.3%), and fever (61.3%). The mean white blood cells (WBCs) count was 14700 ± 5900 (cells/mm3), c-reactive protein (CRP) 270 ± 133 mg/L, lactic acid 1.6 ± 0.85 mmol/L, and albumin 30.3 ± 6.6 g/L. The abdominal CT scans revealed intraabdominal collection in 93.7% of patients, extravasation of contrast in 75%, and pleural effusion in 52.5%. Upper gastrointestinal contrast study (UGIC) showed extravasation of contrast in 77.5% of patients. CONCLUSION: Abdominal pain, tachycardia, or fever after LSG should raise the suspicion of a leak. CT scan of the abdomen and UGIC study detected leaks in 75% and 77.5% consecutively. Only 29.3% of patients were diagnosed correctly as a leak from the first visit to the ER.


Subject(s)
Laparoscopy , Obesity, Morbid , Adult , Anastomotic Leak/diagnostic imaging , Anastomotic Leak/etiology , Gastrectomy/adverse effects , Humans , Laboratories , Middle Aged , Obesity, Morbid/surgery , Retrospective Studies , Treatment Outcome
3.
Int J Surg Case Rep ; 72: 454-459, 2020.
Article in English | MEDLINE | ID: mdl-32698264

ABSTRACT

INTRODUCTION: Giant/large gallstones have high risk of complications, and technical difficulties during surgery. This case series is the largest ever reported. PRESENTATION OF CASES: Case 1: Female (44 years), with one year intermittent right upper quadrant colicky pain. Ultrasound: large gallstone (normal gallbladder). Elective laparoscopic cholecystectomy (LC): 6 × 4 × 3.3 cm gallstone. Case 2: Female (41 years), presented to emergency room with 3 days right upper quadrant pain/tenderness, vomiting, and positive murphy's sign. Ultrasound: large gallstone, calculus cholecystitis. Emergency LC: 4.5 × 3.1 × 3.5 cm gallstone. Case 3: Male (38 years), with history of gallstones and acute cholecystitis presented with intermittent right upper quadrant pain (2 months) and vomiting. Normal abdominal examination. Ultrasound: large gallstone. Elective LC: 4.1 × 4 × 3.6 cm gallstone. CONCLUSIONS: Gallstones >5 cm are very rare, with higher risk of complications. Gallbladder should be removed even if asymptomatic. Gallstones >3 cm have increased risk for gallbladder cancer, biliary enteric fistula and ileus. LC has challenges that include grasping the gallbladder wall, exposure of Calot's triangle, and retrieval of gallbladder out of the abdomen. LC appears to be procedure of choice and should be performed by an experienced surgeon, considering the possibility of conversion to open cholecystectomy in case of inability to expose the anatomy or intraoperative difficulties.

4.
Chemphyschem ; 12(15): 2751-4, 2011 Oct 24.
Article in English | MEDLINE | ID: mdl-22002892

ABSTRACT

The electrochemical synthesis of gallium nanostructures in an ionic liquid is presented. Gallium nanowires and macroporous structures were synthesized by the template-assisted electrodeposition in the ionic liquid 1-butyl-1-methylpyrrolidinium bis(trifluoromethylsulfonyl)amide ([Py(1,4)]TFSA) containing GaCl(3) as the precursor. Track-etched polycarbonate membranes with an average pore diameter of 90 nm and a thickness of 21 µm were used as templates for the nanowire synthesis. Ga nanowires with a length of more than 4 µm and an average diameter corresponding to that of the template's pores were easily obtained by this method. Macroporous structures with an average pore diameter of 600 nm were obtained by the electrochemical deposition of Ga inside polystyrene colloidal crystal templates and the subsequent removal of the template by THF. The macroporous deposit showed a granular morphology with smallest grain sizes of about 40 nm and light reflections. The nanostructures of Ga were characterized by HR-SEM and EDX analysis.

SELECTION OF CITATIONS
SEARCH DETAIL
...