1.
J Radiol Prot ; 38(1): 48-60, 2018 03.
Article in English | MEDLINE | ID: mdl-28980530

ABSTRACT

Simulations with the FLUktuierende KAskade (FLUKA) Monte Carlo code were used to establish the possibility of introducing lead to cover the existing concrete walls of a linear accelerator treatment room maze, in order to reduce the dose of the scattered photons at the maze entrance. In the present work, a pilot study performed at Singleton Hospital in Swansea was used to pioneer the use of lead sheets of various thicknesses to absorb scattered low energy photons in the maze. The dose reduction was considered to be due to the strong effect of the photoelectric interaction in lead resulting in attenuation of the back-scattered photons. Calculations using FLUKA with mono-energetic photons were used to represent the main components of the x-ray spectrum up to 10 MV. Mono-energetic photons were used to enable the study of the behaviour of each energy component from the associated interaction processes. The results showed that adding lead of 1 to 4 mm thickness to the walls and floor of the maze reduced the dose at the maze entrance by up to 80%. Subsequent scatter dose measurements performed at the maze entrance of an existing treatment room with lead sheet of 1.3 mm thickness added to the maze walls and floor supported the results from the simulations. The dose reduction at the maze entrance with the lead in place was up to 50%. The variation between simulation and measurement was attributed to the fact that insufficient lead was available to completely cover the maze walls and floor. This novel proposal of partly, or entirely, covering the maze walls with lead a few millimetres in thickness has implications for the design of linear accelerator treatment rooms since it has the potential to provide savings, in terms of space and costs, when an existing maze requires upgrading in an environment where space is limited and the maze length cannot be extended sufficiently to reduce the dose.


Subject(s)
Particle Accelerators/instrumentation , Radiation Protection/instrumentation , Humans , Monte Carlo Method , Photons , Pilot Projects , Radiation Dosage , Scattering, Radiation
2.
Med Phys ; 42(2): 606-14, 2015 Feb.
Article in English | MEDLINE | ID: mdl-25771559

ABSTRACT

PURPOSE: This study explores the possibility of using lead to cover part of the radiation therapy facility maze walls in order to absorb low energy photons and reduce the total dose at the maze entrance of radiation therapy rooms. METHODS: Experiments and Monte Carlo simulations were utilized to establish the possibility of using high-Z materials to cover the concrete walls of the maze in order to reduce the dose of the scatteredphotons at the maze entrance. The dose of the backscatteredphotons from a concrete wall was measured for various scattering angles. The dose was also calculated by the FLUKA and EGSnrc Monte Carlo codes. The FLUKA code was also used to simulate an existing radiotherapy room to study the effect of multiple scattering when adding lead to cover the concrete walls of the maze. Monoenergetic photons were used to represent the main components of the x ray spectrum up to 10 MV. RESULTS: It was observed that when the concrete wall was covered with just 2 mm of lead, the measured dose rate at all backscattering angles was reduced by 20% for photons of energy comparable to Co-60 emissions and 70% for Cs-137 emissions. The simulations with FLUKA and EGS showed that the reduction in the dose was potentially even higher when lead was added. One explanation for the reduction is the increased absorption of backscatteredphotons due to the photoelectric interaction in lead. The results also showed that adding 2 mm lead to the concrete walls and floor of the maze reduced the dose at the maze entrance by up to 90%. CONCLUSIONS: This novel proposal of covering part or the entire maze walls with a few millimeters of lead would have a direct implication for the design of radiation therapy facilities and would assist in upgrading the design of some mazes, especially those in facilities with limited space where the maze length cannot be extended to sufficiently reduce the dose.


Subject(s)
Construction Materials , Facility Design and Construction , Lead , Photons/therapeutic use , Radiation Dosage , Radiotherapy, High-Energy/instrumentation , Scattering, Radiation , Monte Carlo Method , Radiation Protection
3.
Med Phys ; 42(2): 606-614, 2015 Feb.
Article in English | MEDLINE | ID: mdl-28102603

ABSTRACT

PURPOSE: This study explores the possibility of using lead to cover part of the radiation therapy facility maze walls in order to absorb low energy photons and reduce the total dose at the maze entrance of radiation therapy rooms. METHODS: Experiments and Monte Carlo simulations were utilized to establish the possibility of using high-Z materials to cover the concrete walls of the maze in order to reduce the dose of the scattered photons at the maze entrance. The dose of the backscattered photons from a concrete wall was measured for various scattering angles. The dose was also calculated by the FLUKA and EGSnrc Monte Carlo codes. The FLUKA code was also used to simulate an existing radiotherapy room to study the effect of multiple scattering when adding lead to cover the concrete walls of the maze. Monoenergetic photons were used to represent the main components of the x ray spectrum up to 10 MV. RESULTS: It was observed that when the concrete wall was covered with just 2 mm of lead, the measured dose rate at all backscattering angles was reduced by 20% for photons of energy comparable to Co-60 emissions and 70% for Cs-137 emissions. The simulations with FLUKA and EGS showed that the reduction in the dose was potentially even higher when lead was added. One explanation for the reduction is the increased absorption of backscattered photons due to the photoelectric interaction in lead. The results also showed that adding 2 mm lead to the concrete walls and floor of the maze reduced the dose at the maze entrance by up to 90%. CONCLUSIONS: This novel proposal of covering part or the entire maze walls with a few millimeters of lead would have a direct implication for the design of radiation therapy facilities and would assist in upgrading the design of some mazes, especially those in facilities with limited space where the maze length cannot be extended to sufficiently reduce the dose.


Subject(s)
Lead , Photons , Radiation Protection/instrumentation , Radiotherapy, High-Energy/instrumentation , Scattering, Radiation , Computer Simulation , Facility Design and Construction , Health Facility Environment , Models, Theoretical , Monte Carlo Method , Occupational Exposure/prevention & control , Radiation Dosage , Radiation Exposure/prevention & control , Radiation Protection/methods , Radiotherapy, High-Energy/methods , Software