Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Metabolites ; 10(6)2020 Jun 23.
Article in English | MEDLINE | ID: mdl-32585902

ABSTRACT

Software applications for high resolution mass spectrometry (HRMS)-based non-targeted analysis (NTA) continue to enhance chemical identification capabilities. Given the variety of available applications, determining the most fit-for-purpose tools and workflows can be difficult. The Critical Assessment of Small Molecule Identification (CASMI) contests were initiated in 2012 to provide a means to evaluate compound identification tools on a standardized set of blinded tandem mass spectrometry (MS/MS) data. Five CASMI contests have resulted in recommendations, publications, and invaluable datasets for practitioners of HRMS-based screening studies. The US Environmental Protection Agency's (EPA) CompTox Chemicals Dashboard is now recognized as a valuable resource for compound identification in NTA studies. However, this application was too new and immature in functionality to participate in the five previous CASMI contests. In this work, we performed compound identification on all five CASMI contest datasets using Dashboard tools and data in order to critically evaluate Dashboard performance relative to that of other applications. CASMI data was accessed via the CASMI webpage and processed for use in our spectral matching and identification workflow. Relative to applications used by former contest participants, our tools, data, and workflow performed well, placing more challenge compounds in the top five of ranked candidates than did the winners of three contest years and tying in a fourth. In addition, we conducted an in-depth review of the CASMI structure sets and made these reviewed sets available via the Dashboard. Our results suggest that Dashboard data and tools would enhance chemical identification capabilities for practitioners of HRMS-based NTA.

2.
Anal Bioanal Chem ; 412(6): 1303-1315, 2020 Feb.
Article in English | MEDLINE | ID: mdl-31965249

ABSTRACT

High-resolution mass spectrometry (HRMS) enables rapid chemical annotation via accurate mass measurements and matching of experimentally derived spectra with reference spectra. Reference libraries are generated from chemical standards and are therefore limited in size relative to known chemical space. To address this limitation, in silico spectra (i.e., MS/MS or MS2 spectra), predicted via Competitive Fragmentation Modeling-ID (CFM-ID) algorithms, were generated for compounds within the U.S. Environmental Protection Agency's (EPA) Distributed Structure-Searchable Toxicity (DSSTox) database (totaling, at the time of analysis, ~ 765,000 substances). Experimental spectra from EPA's Non-Targeted Analysis Collaborative Trial (ENTACT) mixtures (n = 10) were then used to evaluate the performance of the in silico spectra. Overall, MS2 spectra were acquired for 377 unique compounds from the ENTACT mixtures. Approximately 53% of these compounds were correctly identified using a commercial reference library, whereas up to 50% were correctly identified as the top hit using the in silico library. Together, the reference and in silico libraries were able to correctly identify 73% of the 377 ENTACT substances. When using the in silico spectra for candidate filtering, an examination of binary classifiers showed a true positive rate (TPR) of 0.90 associated with false positive rates (FPRs) of 0.10 to 0.85, depending on the sample and method of candidate filtering. Taken together, these findings show the abilities of in silico spectra to correctly identify true positives in complex samples (at rates comparable to those observed with reference spectra), and efficiently filter large numbers of potential false positives from further consideration. Graphical abstract.

3.
Sci Data ; 6(1): 141, 2019 08 02.
Article in English | MEDLINE | ID: mdl-31375670

ABSTRACT

Confident identification of unknown chemicals in high resolution mass spectrometry (HRMS) screening studies requires cohesive workflows and complementary data, tools, and software. Chemistry databases, screening libraries, and chemical metadata have become fixtures in identification workflows. To increase confidence in compound identifications, the use of structural fragmentation data collected via tandem mass spectrometry (MS/MS or MS2) is vital. However, the availability of empirically collected MS/MS data for identification of unknowns is limited. Researchers have therefore turned to in silico generation of MS/MS data for use in HRMS-based screening studies. This paper describes the generation en masse of predicted MS/MS spectra for the entirety of the US EPA's DSSTox database using competitive fragmentation modelling and a freely available open source tool, CFM-ID. The generated dataset comprises predicted MS/MS spectra for ~700,000 structures, and mappings between predicted spectra, structures, associated substances, and chemical metadata. Together, these resources facilitate improved compound identifications in HRMS screening studies. These data are accessible via an SQL database, a comma-separated export file (.csv), and EPA's CompTox Chemicals Dashboard.

SELECTION OF CITATIONS
SEARCH DETAIL
...