Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
2.
Arch Gynecol Obstet ; 291(5): 1121-6, 2015 May.
Article in English | MEDLINE | ID: mdl-25367600

ABSTRACT

OBJECTIVES: To compare the diagnostic accuracy of brush endometrial sampling with conventional dilatation and curettage in women with abnormal uterine bleeding. PATIENTS AND METHODS: Two hundred and twenty (220) women with abnormal uterine bleeding were included in this comparative study; endometrial sampling was done before cervical dilatation using Tao Bruch followed by conventional dilatation and curettage (D&C). The histopathology report of the Tao Bruch samples was compared with that of the D&C samples and the D&C results were considered as the gold standard. RESULTS: 100% of samples obtained by conventional D&C, while 98.2% of the samples obtained by Tao Brush were adequate for histopathology examination. In this study; Tao Brush had 100% sensitivity, 100% specificity, 100% predictive values and accuracy for diagnosing endometrial hyperplasia, endometrial carcinoma, proliferative and secretory endometrium, also, it had 86.7% sensitivity, 100% specificity, 100% positive predictive value (PPV) and 99% negative predictive value (NPV) and accuracy for diagnosing endometritis (no significant difference compared to conventional D&C), while, it had 77.8% sensitivity, 100% specificity, 100% PPV and 99% NPV and accuracy for diagnosing endometrial polyps (no significant difference compared to conventional D&C) CONCLUSION: Endometrial sampling using endometrial brush cytology (EBC) is safe, accurate, cost-effective outpatient procedure, avoids general anesthesia with high sensitivity and specificity for detection of endometrial hyperplasia and endometrial carcinoma. EBC could be used as complementary diagnostic tool when hysteroscopic biopsies or other blinded procedures for endometrial sampling are unwanted or not available.


Subject(s)
Biopsy/methods , Dilatation and Curettage , Endometrial Hyperplasia/diagnosis , Endometrial Neoplasms/diagnosis , Endometritis/diagnosis , Endometrium/pathology , Specimen Handling/methods , Uterine Hemorrhage/etiology , Adult , Endometrial Hyperplasia/pathology , Endometrial Neoplasms/pathology , Endometritis/pathology , Female , Humans , Middle Aged , Polyps/pathology , Predictive Value of Tests , Pregnancy , Sensitivity and Specificity , Uterine Neoplasms/pathology
3.
Arch Osteoporos ; 9: 189, 2014.
Article in English | MEDLINE | ID: mdl-25037077

ABSTRACT

SUMMARY: Osteoporosis is a major cause of mortality and morbidity worldwide. Decreased bone turnover markers and increased lumbar spine and total hip bone mineral density (BMD) in raloxifene-treated women add further support to the idea that raloxifene is an effective well-tolerated option for treating Kuwaiti postmenopausal osteoporosis, suitable for long-term use. INTRODUCTION/PURPOSE: Osteoporosis is currently a major cause of mortality, morbidity, and medical expense worldwide, and it is important to investigate therapies for the prevention and treatment of osteoporosis in postmenopausal women. This study was designed to detect the effect of raloxifene hydrochloride on bone mineral density and bone turnover in Kuwaiti postmenopausal women with osteoporosis. METHODS: Postmenopausal women who were free of severe or chronically disabling conditions, had their last menstrual period at least 2 years before the beginning of the study, had a T score for femoral neck or lumbar spine BMD measurements ≤2.5, and were without fractures were included in this study. One hundred and seventy-six (176) women were included in this study and were divided into two groups; the first group (study) received raloxifene with calcium and vitamin D daily for 12 months, and the second group (control) received only calcium and vitamin D. BMD and bone metabolism markers were measured before and after treatment. RESULTS: One year after treatment, BMD of lumbar spine and total hip was significantly increased in study group (3.21 ± 5.4 and 1.62 ± 7.4, respectively) compared to controls (0.9 ± 3.8 and -0.8 ± 5.6, respectively); also, Ward's triangle and trochanter BMD was significantly increased in study group (4.84 ± 9.3 and 1.78 ± 8.5, respectively) compared to controls (1.53 ± 6.6 and -1. 4 ± 6.4, respectively). C-telopeptide was significantly decreased in study group (121 ± 7.8) compared to control group (1,480 ± 6.3); also, serum osteocalcin was significantly decreased in study group (14.5 ± 8.3) compared to control group (43.8 ± 1.3) 1 year after treatment. Occurrence of fractures during this study was significantly low in raloxifene group compared to controls (0 (0%) versus 3 (3.6%), respectively). CONCLUSIONS: Raloxifene appears to be an effective, well-tolerated option for treating osteoporosis in Kuwaiti postmenopausal women, suitable for long-term use.


Subject(s)
Bone Density Conservation Agents/therapeutic use , Bone Density/drug effects , Bone Remodeling/drug effects , Osteoporosis, Postmenopausal/drug therapy , Raloxifene Hydrochloride/therapeutic use , Aged , Biomarkers/metabolism , Case-Control Studies , Female , Humans , Kuwait , Osteoporosis, Postmenopausal/physiopathology , Osteoporotic Fractures/physiopathology , Osteoporotic Fractures/prevention & control
4.
Arch Gynecol Obstet ; 290(3): 457-64, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24715211

ABSTRACT

OBJECTIVES: To compare accuracy of fetal fibronectin (fFN) versus placental alpha microglobulin-1 for detection of premature rupture of fetal membranes (PROM). METHODS: Two hundred and twenty pregnant women >34 and <37 weeks were included in this comparative prospective study and divided into two groups according to presence or absence of PROM. The diagnosis of PROM was based on patient's history of sudden gush of water, pooling of amniotic fluid, positive ferning, positive nitrazine test, confirmed by visualization of fluid passing from the cervical canal and amniotic fluid index ≤5 cm measured by trans-abdominal ultrasound. Patients included in this study were examined by sterile speculum for visualization of membranes and for collection of samples (swabs) from posterior vaginal fornix. RESULTS: Sensitivity and specificity of AmniSure test to diagnose PROM were 97.3 and 98.2 %, respectively, compared with 94.5 and 89.1 %, respectively, for fFN test. Positive predictive value, negative predictive value, and accuracy of AmniSure test to diagnose PROM were 98.2, 97.3, and 97.7 %, respectively, compared with 89.7, 94.2, and 91.8 %, respectively, for fFN test. Predictive values and accuracy of fFN test to diagnose PROM were statistically insignificant compared with predictive values and accuracy of ferning, nitrazine and AmniSure tests. CONCLUSION: fFN bedside test is better than nitrazine and ferning tests in detection of PROM, but is not suited for identification of clinically difficult cases with suspected PROM, because, it is influenceable and can give false-positive results in preterm labor, women >34 gestational weeks and after any vaginal manipulation without PROM.


Subject(s)
Amniotic Fluid/chemistry , Fetal Membranes, Premature Rupture/diagnosis , Fibronectins/analysis , Insulin-Like Growth Factor Binding Protein 1/analysis , Adult , Azo Compounds , Biomarkers/analysis , Case-Control Studies , Crystallization , Female , Humans , Immunoassay , Predictive Value of Tests , Pregnancy , Prospective Studies , Reagent Strips , Sensitivity and Specificity , Specimen Handling , Young Adult
5.
J Turk Ger Gynecol Assoc ; 15(4): 245-9, 2014.
Article in English | MEDLINE | ID: mdl-25584035

ABSTRACT

OBJECTIVE: To detect the maternal and obstetrical factors associated with successful trial of vaginal birth among women with a previous cesarean delivery. MATERIAL AND METHODS: A total of 122 women who were eligible for a trial of labor after cesarean section (TOLAC) according to departmental protocol were included in this comparative prospective study. After informed consent, the women included in this study were subjected to a thorough history to detect maternal and obstetric characteristics and a standard examination to estimate fetal weight, engagement of the fetal head, intra-partum features of fetal membranes, and cervical dilatation. After delivery, data on duration of labor, labor augmentation, mode of delivery, birth outcome, and neonatal intensive care (NICU) admission were recorded and analyzed. RESULTS: Trial of labor after cesarean section was successful in 72.13% and was unsuccessful in 27.87%. Body mass index (BMI) was significantly lower in the successful TOLAC group compared to the unsuccessful group (23.8±0.03 versus 26.2±0.02 kg/m(2)), and the number of women with BMI >25 kg/m(2) was significantly high in the unsuccessful group; also, mean gestational age was significantly lower in the successful TOLAC group compared to the unsuccessful group (37.5±0.04 versus 38.5±0.03 weeks), and the number of women admitted in labor with gestation ≥40 weeks was significantly high in the unsuccessful group. The number of women admitted with >2/5 of fetal head palpable abdominally and fetal head station ≥-2 was significantly high in the unsuccessful TOLAC group. CONCLUSION: In carefully selected cases, TOLAC is safe and often successful. Presence of BMI >25 kg/m(2), gestation ≥40 weeks, and vertex station ≥-2 were risk factors for unsuccessful TOLAC.

SELECTION OF CITATIONS
SEARCH DETAIL
...