J Mother Child ; 27(1): 79-82, 2023 Jun 01.
Article in English | MEDLINE | ID: mdl-37409657

ABSTRACT

A 29-year-old parous woman with a history of a T-shaped copper intrauterine device (IUD) insertion presented 8 months later with a complaint of the contraceptive device being missing. Computed tomography with contrast turned out to be superior to the combined abdominal and pelvic X-ray and transvaginal ultrasound in providing the detailed extrauterine location of the device between the urinary bladder and uterus. A laparoscopy was successful in the atraumatic freeing of the IUD from omental and bladder adhesions, and in its final removal.