Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
J Phys Chem Lett ; 15(16): 4391-4399, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38621259

ABSTRACT

Water often serves as both a reactant and solvent in electrocatalytic reactions. Interfacial water networks can affect the transport and kinetics of these reactions, e.g., hydrogen evolution reaction and CO2 reduction reaction. Adding cosolvents that influence the hydrogen-bonding (H-bonding) environment, such as dimethyl sulfoxide (DMSO), has the potential to tune the reactivity of these important electrocatalytic reactions by regulating the interfacial local environment and water network. We investigate interfacial H-bonding networks in water-DMSO cosolvent mixtures on gold surfaces by using surface-enhanced infrared absorption spectroscopy and molecular dynamics simulations. Experiments and simulations show that the gold surface is enriched with dehydrated DMSO molecules and the mixture phase-separates to form water clusters. Simulations show a "buckled" water conformation at the surface, further constraining interfacial H-bonding. The small size of these water clusters and the energetically unfavorable H-bond conformations might inhibit H-bonding with bulk water, suppressing the proton diffusion required for efficient hydrogen evolution reaction processes.

2.
Annu Rev Phys Chem ; 75(1): 283-305, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38382566

ABSTRACT

Cell membranes are incredibly complex environments containing hundreds of components. Despite substantial advances in the past decade, fundamental questions related to lipid-lipid interactions and heterogeneity persist. This review explores the complexity of lipid membranes, showcasing recent advances in vibrational spectroscopy to characterize the structure, dynamics, and interactions at the membrane interface. We include an overview of modern techniques such as surface-enhanced infrared spectroscopy as a steady-state technique with single-bilayer sensitivity, two-dimensional sum-frequency generation spectroscopy, and two-dimensional infrared spectroscopy to measure time-evolving structures and dynamics with femtosecond time resolution. Furthermore, we discuss the potential of multiscale molecular dynamics (MD) simulations, focusing on recently developed simulation algorithms, which have emerged as a powerful approach to interpret complex spectra. We highlight the ongoing challenges in studying heterogeneous environments in multicomponent membranes via current vibrational spectroscopic techniques and MD simulations. Overall, this review provides an up-to-date comprehensive overview of the powerful combination of vibrational spectroscopy and simulations, which has great potential to illuminate lipid-lipid, lipid-protein, and lipid-water interactions in the intricate conformational landscape of cell membranes.


Subject(s)
Cell Membrane , Lipid Bilayers , Molecular Dynamics Simulation , Vibration , Cell Membrane/chemistry , Cell Membrane/metabolism , Lipid Bilayers/chemistry , Membrane Lipids/chemistry , Spectrophotometry, Infrared/methods , Water/chemistry , Membrane Proteins/chemistry
3.
Biophys J ; 2023 Dec 23.
Article in English | MEDLINE | ID: mdl-38142298

ABSTRACT

Cell signaling is an important process involving complex interactions between lipids and proteins. The myristoylated alanine-rich C-kinase substrate (MARCKS) has been established as a key signaling regulator, serving a range of biological roles. Its effector domain (ED), which anchors the protein to the plasma membrane, induces domain formation in membranes containing phosphatidylinositol 4,5-bisphosphate (PIP2) and phosphatidylserine (PS). The mechanisms governing the MARCKS-ED binding to membranes remain elusive. Here, we investigate the composition-dependent affinity and MARCKS-ED-binding-induced changes in interfacial environments using two-dimensional infrared spectroscopy and fluorescence anisotropy. Both negatively charged lipids facilitate the MARCKS-ED binding to lipid vesicles. Although the hydrogen-bonding structure at the lipid-water interface remains comparable across vesicles with varied lipid compositions, the dynamics of interfacial water show divergent patterns due to specific interactions between lipids and peptides. Our findings also reveal that PIP2 becomes sequestered by bound peptides, while the distribution of PS exhibits no discernible change upon peptide binding. Interestingly, PIP2 and PS become colocalized into domains both in the presence and absence of MARCKS-ED. More broadly, this work offers molecular insights into the effects of membrane composition on binding.

4.
Opt Express ; 31(2): 2700-2709, 2023 Jan 16.
Article in English | MEDLINE | ID: mdl-36785278

ABSTRACT

BoxCARS and pump-probe geometries are common implementations of two-dimensional infrared (2D IR) spectroscopy. BoxCARS is background-free, generally offering greater signal-to-noise ratio, which enables measuring weak vibrational echo signals. Pulse shapers have been implemented in the pump-probe geometry to accelerate data collection and suppress scatter and other unwanted signals by precise control of the pump-pulse delay and carrier phase. Here, we introduce a 2D-IR optical setup in the BoxCARS geometry that implements a pulse shaper for rapid acquisition of background-free 2D IR spectra. We show a signal-to-noise improvement using this new fast-scan BoxCARS setup versus the pump-probe geometry within the same configuration.

5.
J Phys Chem A ; 126(23): 3816-3825, 2022 Jun 16.
Article in English | MEDLINE | ID: mdl-35668543

ABSTRACT

Ultrafast spectroscopy often involves measuring weak signals and long data acquisition times. Spectra are typically collected as a "pump-probe" spectrum by measuring differences in intensity across laser shots. Shot-to-shot intensity fluctuations are most often the primary source of noise in ultrafast spectroscopy. Here, we present a novel approach for denoising ultrafast two-dimensional infrared (2D IR) spectra using conditional generative adversarial neural networks (cGANNs). The cGANN approach is able to eliminate shot-to-shot noise and reconstruct the line shapes present in the noisy input spectrum. We present a general approach for training the cGANN using matched pairs of noisy and clean synthetic 2D IR spectra based on the Kubo-line shape model for a three-level system. Experimental shot-to-shot laser noise is added to synthetic spectra to recreate the noise profile present in measured experimental spectra. The cGANNs can recover line shapes from synthetic 2D IR spectra with signal-to-noise ratios as low as 2:1, while largely preserving the key features such as center frequencies, line widths, and diagonal elongation. In addition, we benchmark the performance of the cGANN using experimental 2D IR spectra of an ester carbonyl vibrational probe and demonstrate that, by applying the cGANN denoising approach, we can extract the frequency-frequency time correlation function (FFCF) from reconstructed spectra using a nodal-line slope analysis. Finally, we provide a set of practical guidelines for extending the denoising method to other coherent multidimensional spectroscopies.


Subject(s)
Neural Networks, Computer , Vibration , Signal-To-Noise Ratio , Spectrophotometry, Infrared/methods
6.
J Phys Chem A ; 125(29): 6498-6504, 2021 Jul 29.
Article in English | MEDLINE | ID: mdl-34259508

ABSTRACT

Ultrafast two-dimensional infrared (2D IR) spectroscopy and Fourier transform infrared (FTIR) spectroscopy are often performed in tandem, with FTIR typically used to interpret and provide hypotheses for 2D IR experiments. Comparisons between 2D IR and FTIR spectra can also be used to examine the structure and orientation in systems of coupled vibrational chromophores. The most common method for comparing 2D IR and FTIR lineshapes, the diagonal slice method, contains significant artifacts when applied to oscillators with low anharmonicities. Here, we introduce a new technique, the pump slice amplitude (PSA) method, for relating 2D IR lineshapes to FTIR lineshapes and compare PSAs against diagonal slices using theoretical and experimental spectra. We find that PSAs are significantly more similar to FTIR lineshapes than diagonal slices in systems with low anharmonicity.

SELECTION OF CITATIONS
SEARCH DETAIL
...