Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 8 de 8
Filter
Add more filters










Database
Language
Publication year range
1.
Heliyon ; 10(11): e32557, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38961985

ABSTRACT

Background/purpose: Recently, a group of universal single-shade resin-based composites (RBCs) has been developed to simplify the process of shade selection. Excellent mechanical and physical properties are crucial for the ultimate success and clinical longevity of restorations. Therefore, evaluating the properties of the single-shaded RBCs is imperative. This study aimed to determine the flexural strength (FS) and degree of conversion (DC) of universal single-shade RBCs. Materials and methods: In this study, four commercial RBCs were used; three universal single-shade RBCs; Omnichroma (OC), Charisma® Diamond ONE (CD), and Vittra APS Unique (VU), and a conventional nanohybrid composite Filtek™ Z250 XT (FT) which was used as a control. Sixty composite beams and 40 composite discs were used for FS and DC, respectively. A universal test machine with a three-point bending test was used to measure the FS, whereas the DC was measured using a Fourier-transform infrared spectrometer (FTIR). Three fractured specimens from each resin composite group were qualitatively analyzed using scanning electron microscopy. Results: ANOVA was used to compare the mean values of FS and DC among the four RBCs (OC, CD, VU, and FT). Highly significant differences were observed in the mean FS and DC values (F = 673.043, p < 0.001 and F (=782.4, p < 0.0001), respectively. The highest FS was observed in the CD group, followed by FT and VU groups; the lowest value was observed in the OC group. In addition, a statistically significant difference was identified in DC values. The highest DC value was observed in VU, followed by OC and CD, and the lowest DC value was observed in FT. Conclusion: Universal single-shade RBCs demonstrated a good FS, except for OC, which exhibited a significantly low FS. The DC of the universal single-shade RBCs was higher than that of the conventional nanohybrid composite restorative material.

2.
BMC Oral Health ; 24(1): 197, 2024 Feb 07.
Article in English | MEDLINE | ID: mdl-38326838

ABSTRACT

BACKGROUND: Recently, universal single-shade resin composites have become increasingly available in the dental market. The modification of their composition can have an inadvertent effect on their physical and surface properties, and subsequently determinantal effect on their clinical function and longevity. Therefore, this study aimed to evaluate the effect of different finishing and polishing (F/P) systems on surface roughness (Ra), surface gloss (GU), and Vickers microhardness (VMH) of universal single-shade RBCs. MATERIALS AND METHODS: Four commercial RBCs were used; the universal single-shade RBCs were Omnichroma, Charisma® Diamond ONE, and Vittra APS Unique, and a conventional nanocomposite Filtek™ Z250 XT was used as a control. The 3 F/P systems were Sof-Lex™ XT, Enhance®/PoGo®, and Diacomp® Plus Twist. A total of 160 discs were used for the 3 F/P system groups for all RBCs (n = 10). After F/P, the Ra, GU, and VMH were assessed. The data were analyzed using 2-way ANOVA at p-value < 0.05. RESULTS: Significant differences were found among the four RBCs and the 3 F/P systems (p < .000). Omnichroma showed the lowest Ra and acceptable GU, but the lowest VMH. Charisma showed the highest Ra, acceptable GU, and VMH. Vittra showed acceptable Ra, GU, and VMH and Filtek showed the highest GU, VMH, and acceptable Ra. CONCLUSION: Although conventional nanohybrid RBC (Filtek Z250 XT) showed better GU and VMH values, the universal single-shade RBCs demonstrated comparable surface properties. The highest GU & VMH and lowest Ra were achieved by Diacomp followed by Enhance and Soflex.


Subject(s)
Composite Resins , Dental Polishing , Humans , Materials Testing , Dental Materials , Diamond , Surface Properties
3.
Saudi Dent J ; 34(5): 362-368, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35814845

ABSTRACT

Objectives: To evaluate the effect of light curing unit (LCU) types and distance from light curing unit tip on the translucency parameters (TP) of bulk fill composite materials. Materials and Methods: Two bulk-fill resin composites and one nanohybrid composite were used in this study. The specimens were divided into groups based on the type of curing unit used, and further subdivided based on the distance of the curing source to the surface of the resin composite. Translucency was evaluated at 4 mm thickness (for the bulk-fill) and 2 mm thickness (for nanohybrid) after curing using two different light curing units at zero, 2 mm, and 4 mm distance. The results were analyzed using two-way ANOVA at the significance level of a p-value of < 0.05. Results: Among all the tested materials, Filtek Bulk Fill Posterior RBC showed the highest TP at 0 mm distance when cured with Blue phase G2 LED LCU and it was the least affected by the differences in distances. However, Filtek Z350 nanohybrid composite had no significant differences between the three distances when cured with Blue phase G2 LCU. Conclusion: Translucency values among the studied bulk-fill materials are affected by material composition, curing units and the distance of the tip of the light source to the restoration surface.

4.
J Contemp Dent Pract ; 22(4): 342-348, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34267000

ABSTRACT

AIM AND OBJECTIVE: The purpose of this study was to investigate the fracture resistance of marginal ridges restored using different techniques (amalgam, open sandwich technique, and incremental placement) and to compare these with smart dentin replacement (SDR) bulk-fill. MATERIALS AND METHODS: Amalgam, dispersalloy; a nanohybrid resin composite (Tetric N Ceram), a resin-modified glass ionomer cement (RMGIC) base (Fuji II LC), and flowable bulk-fill composites (SureFil SDR) were used. Standardized class II (occluso-distal) OD cavities were prepared on 60 (n = 12) extracted premolars, and five different protocols were used to restore the teeth: group 1, dispersalloy; group 2, dispersalloy with 4 mm Fuji II LC base; group 3, incrementally placed Tetric N Ceram; group 4, Tetric N Ceram with 4 mm Fuji II LC base; and group 5, Tetric N Ceram with SureFil SDR. The restorations were thermocycled then fractured using a universal testing machine, the maximum fracture load of the specimens was measured (N), and the type of fracture was recorded. Statistical analysis was carried out using one-way analysis of variance. RESULTS: Amalgam groups showed the lowest fracture resistance, with no significant difference between the based and nonbased groups. The highest fracture resistance was displayed by Tetric N Ceram with SDR base, and it was significantly higher than all the groups except the Tetric N Ceram nonbased group. The RMGIC based Tetric N Ceram displayed intermediate fracture resistance. The majority of the restorations showed mixed types of fracture except for nonbased amalgam, which mostly failed cohesively through amalgam. SDR-based composite was the only group that showed severe tooth failures. CONCLUSIONS: The use of a 4 mm thick RMGIC base had no detrimental effect on the fracture resistance of class II amalgam and composite restorations. CLINICAL SIGNIFICANCE: Bulk-fill SureFil SDR placed under a conventional resin-based composite had similar fracture resistance to incrementally placed composite but higher than amalgam and composite restorations based on RMGIC.


Subject(s)
Dental Restoration, Permanent , Laboratories , Bicuspid , Composite Resins , Dental Materials , Glass Ionomer Cements , Materials Testing
5.
Clin Cosmet Investig Dent ; 12: 571-579, 2020.
Article in English | MEDLINE | ID: mdl-33324111

ABSTRACT

PURPOSE: The influence of different light-emitting diode (LED) curing light intensities on the translucency and surface gloss of bulk-fill resin-based composite (RBC) restorative materials was evaluated. MATERIALS AND METHODS: Forty specimens of each RBC (Filtek One bulk-fill posterior, Reveal HD bulk, Tetric N-Ceram, and Filtek Z350) were prepared. The RBCs were shaped into molds and cured using an LED curing light unit at high intensity (1,200 mW/cm2) for 20 s and low intensity (650 mW/cm2) for 40 s. A spectrophotometer was used to determine the translucency, and a gloss meter was used to evaluate surface gloss. Data were analyzed using one- and two-way analysis of variance (ANOVA), independent t-test, and Tukey's and Scheffe's post hoc multiple comparison tests. RESULTS: The highest translucency value was observed for Reveal HD (7.688 ± 0.861) with a high curing intensity, while Filtek One showed the lowest value (1.750 ± 0.376) with a low curing intensity. The materials showed no significant difference in surface gloss with a high curing intensity. With low-intensity light curing, Filtek One showed the highest gloss value (55.270 ± 10.106), while Tetric N-Ceram and Reveal HD showed the lowest gloss values (35.560 ± 6.533 and 35.680 ± 6.648, respectively). CONCLUSION: Curing light intensity had no effect on both the gloss and translucency for all the materials tested, although for Tetric N-Ceram, higher intensity corresponded to higher gloss values while for Filtek One, higher intensity corresponded to a higher translucency value.

6.
Eur J Dent ; 14(2): 233-238, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32396969

ABSTRACT

OBJECTIVE: The aim of this study was to assess: (1) the perceptions of dentists in Saudi Arabia concerning the amalgam controversy, (2) their attitude toward the ethical responsibility of patient information, and (3) patients' knowledge and attitude toward the use of dental amalgam. MATERIALS AND METHODS: A total of 1,139 dentists were sampled on convenience by electronic survey. The questionnaire contained questions about the safety of dental amalgam, use of amalgam, case selection, alternate materials, and informing their patients about risks of amalgam. Also, 425 patients were sampled on convenience and information collected on their knowledge about amalgam and its acceptance in their oral cavities. RESULTS: A total of 201 dentists and 425 patients participated in the study. A total of 60% of dentists and specialists declared it safe. A total of 32.4% (31) of general dental practitioners and 41% (43) specialists considered it a moral obligation to inform patients about the potential health risks associated with amalgam. Mercury toxicity was identified as the most common health hazard. About 57.3% dentists and 36.2% specialists opted for superior longevity as the principle advantage. Majority of patients (52.2%) in Saudi Arabia had no knowledge about dental amalgam. While 23.1% (98) had concern about poor color, 8.7% (30) knew it contained silver while only 7.8% (27) patients were aware of its mercury content. CONCLUSION: Majority of dentists in Saudi Arabia found it safe to use amalgam while the patients had little knowledge about the possible issues with amalgam. It is recommended to improve public awareness about impact of mercury containing products on the environment.

7.
Saudi Dent J ; 25(2): 61-7, 2013 Apr.
Article in English | MEDLINE | ID: mdl-24748758

ABSTRACT

BACKGROUND/PURPOSE: Few studies investigated the best method for removing stains from different types of resin-based composite restorations and compared them to the more recently introduced nanocomposites. This study compared the effect of four methods for stain removal from composite resins; finishing with Sof-lex disks, using pumice and brush, bleaching with 10% carbamide peroxide and 38% hydrogen peroxide. MATERIALS AND METHODS: Twenty disk specimens were prepared. Specimens were immersed in a staining solution for 3 weeks. The stained surfaces of five specimens from each RBC material were treated with one of the treatment procedures. Colorimetric measurements were taken using spectrophotometer prior to and after staining, and then repeated after surface treatments. Color difference values were calculated. RESULTS: One-way ANOVA indicated significant differences in color change of the three composite resin materials following staining. Filtek Z250 showed the least susceptibility to discoloration followed by Renamel, Filtek Supreme was the material most prone to discoloration. Two-way ANOVA and Tukey's Post Hoc showed that all stain removing procedures except polishing with pumice, were able to return Filtek Z250 to clinically acceptable color difference. While bleaching with 38% carbamide peroxide was not effective with Renamel. Only pumice and 10% carbamide peroxide were able to return Renamel to clinically acceptable color difference. CONCLUSION: Compositions of resin-based composite resins play an important role in their susceptibility to stain and their amenability to stain removal procedures. Home bleaching showed good results for the three materials, while office bleach was the least effective.

8.
J Contemp Dent Pract ; 7(4): 9-16, 2006 Sep 01.
Article in English | MEDLINE | ID: mdl-16957786

ABSTRACT

AIM: Despite the improvements to compomer materials, the bond strength of these materials remains inferior to "composite/resin bonding" systems and limits their clinical use. The purpose of this study was to evaluate the effect of acidic conditioning with phosphoric acid and Prompt L-Pop (PLP) on the shear bond strength of two compomers Dyract AP (DAP) and Composan Glass (CG) to dentin. METHODS AND MATERIALS: Sixty extracted bovine teeth were used to test the shear bond strength of two compomers to flat dentin labial surfaces. The dentin specimens were randomly assigned to six groups of ten specimens each: Group 1: DAP and Prime & Bond NT (PBNT); Group 2: DAP/PBNT with a 15 second dentin etch prior to bonding; Group 3: DAP placed with PLP adhesive; Group 4: CG and Compobond NE (CBNE); Group 5: CG/CBNE with a 15 second dentin etch; and Group 6: CG placed with PLP adhesive. The specimens were stored at 37 masculineC with 100% humidity for 24 hours then mounted and sheared using an Instron Universal Testing Machine at a cross head speed of 0.5 mm/min. The results were recorded in Mega Pascals (MPa). The sheared specimens were examined under a light microscope, and the type of failure (adhesive, cohesive, or mixed) was recorded. RESULTS: The mean dentin shear bond strength value (MPa) for the groups was: Group 1 (11.6+/-3.9); Group 2 (13.2+/-3.3); Group 3 (12.4+/-2.0); Group 4 (13.0+/-4.3); Group 5 (19.3+/-3.7); and Group 6 (13.1+/-3.0). One way analysis of variance (ANOVA) and Tukey HSD post-hoc tests detected a significantly higher bond strength (P = 0.003) for group 5. For groups 1, 3, 4, and 6, the mode of failure was mostly adhesive. When acid etching of dentin was performed (groups 2 and 5), cohesive fracture within dentin was the predominant mode of failure. Acid etching and the use of PLP significantly reduced the number of adhesive fractures and reduced variability in the shear bond strength results. CONCLUSIONS: Acid etching significantly increased the shear bond strength of CG to dentin but did not affect DAP. The application of PLP resulted in a shear bond strength not statistically different from PBNT or CPNE. CG bond to dentin is improved with acid etching using phosphoric acid. However, PLP provided no significant improvement in the shear bond strength of DAP and CG.


Subject(s)
Acid Etching, Dental/methods , Compomers , Dental Bonding , Dental Restoration, Permanent/methods , Dentin-Bonding Agents , Analysis of Variance , Animals , Cattle , Dental Stress Analysis , Dentin , Materials Testing , Phosphoric Acids , Resin Cements , Shear Strength , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL
...