Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Biomed Chromatogr ; 20(4): 365-8, 2006 Apr.
Article in English | MEDLINE | ID: mdl-16167302

ABSTRACT

A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the determination of ziprasidone (ZIP) in human plasma was developed. ZIP and N-methyl ziprasidone as internal standard (IS) were extracted from alkalinized plasma using tert- butyl methyl ether. Separation was performed isocratically on a C8 column with 90% acetonitrile containing 2 mmol/L ammonium acetate as a mobile phase with a total run time of 2.5 min. MS/MS transitions of m/z 413 --> 194 and m/z 427 --> 177 of the analyte and internal standard were used for quantification. Confirmatory ions of m/z 413 --> 177 and m/z 427 --> 180 were collected as well. The calibration curve based on peak-area ratio was linear up to at least 200 ng/mL with a detection limit of 0.1 ng/mL. The method showed satisfactory reproducibility with a coefficient of variation of less than 5%. The method was successfully applied to the analysis of ZIP in spiked human plasma.


Subject(s)
Chromatography, Liquid/methods , Piperazines/blood , Spectrometry, Mass, Electrospray Ionization/methods , Thiazoles/blood , Sensitivity and Specificity
2.
Clin Chim Acta ; 359(1-2): 179-88, 2005 Sep.
Article in English | MEDLINE | ID: mdl-15978564

ABSTRACT

BACKGROUND: Glutaric aciduria type I (GA1) is an autosomal recessive disorder that usually causes neurological damage. Early diagnosis of the disease prior to the appearance of clinical symptoms can lead to better outcomes. METHODS: We describe a simple and selective HPLC method with intramolecular excimer-forming fluorescence derivatization to diagnose GA1. Glutaric acid (GA) and 3-hydroxyglutaric acid (3HGA) in urine and an internal standard were derivatized with 1-pyrenebutyric hydrazide (PBH). The derivatives were separated on a C18 column and fluorometrically detected at 475 nm (excitation of 345 nm) with a run time of 18 min. RESULTS: Excellent linearity over a wide range, reproducibility (coefficient of variation < or =14.5%), and sensitivity (limit of detection 0.4 micromol/l 3HGA and 0.2 micromol/l GA) were obtained. A retrospective study on previously diagnosed GA1 patients' urine from our laboratory archives between 1999 and 2004 was performed by analysts blinded to the study. CONCLUSIONS: The method enabled us to differentiate GA1 cases (n=36) from controls (n=99), regardless of the years of urine storage. The method is valuable for both retrospective and prospective diagnoses of GA1.


Subject(s)
Chromatography, High Pressure Liquid/methods , Glutarates/urine , Metabolism, Inborn Errors/urine , Spectrometry, Fluorescence/methods , Case-Control Studies , Glutarates/blood , Humans , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS