Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Endovasc Ther ; 26(5): 637-642, 2019 10.
Article in English | MEDLINE | ID: mdl-31303096

ABSTRACT

Purpose: To prospectively evaluate the safety and efficacy of the TIGRIS Vascular Stent in the superficial femoral artery (SFA) and proximal popliteal artery within a treatment algorithm that reserved stent usage for more challenging patients. Materials and Methods: This prospective, single-center study enrolled 97 patients (mean age 68.7 years; 66 men) who were treated for 100 de novo or nonstented restenotic femoropopliteal lesions (≥70% stenosis) and had recoil or dissection after plain balloon predilation. The average lesion length was 5.6±2.3 cm (maximum 8 cm per protocol). The composite primary efficacy outcome was 12-month primary patency, defined as a peak systolic velocity ratio ≤2.5 at the stented target lesion on duplex ultrasound, and no clinically-driven reintervention within the stented segment. The primary safety outcome was freedom from device- and procedure-related target vessel revascularization, target limb major amputation (above the metatarsals), or death through 30 days. Secondary outcomes included secondary patency, clinically-driven target lesion revascularization (TLR), Rutherford category change relative to baseline, and binary restenosis of the target lesion. Results: All devices were successfully implanted with no device-related complications at the time of implant or within the 30-day postimplant window. The average stented length was 7.0±2.5 cm; no stent elongation was observed during deployment. One patient was lost to follow-up before 12 months and another died of an unrelated cause, leaving 95 patients (98 lesions) available for 12-month follow-up and 77 patients/lesions for the 24-month preliminary analysis. The binary primary and secondary patency rates at 12 months were 92.9% and 100%. The binary freedom from TLR was 94.9%. At 24 months, the Kaplan-Meier estimate of primary patency was 90.0%. Conclusion: This prospective study demonstrated that the TIGRIS Vascular Stent is a safe and effective device in a modern treatment algorithm that reserved bare stent use for postangioplasty dissection or recoil in distal femoropopliteal arteries.


Subject(s)
Algorithms , Angioplasty, Balloon/instrumentation , Decision Support Techniques , Femoral Artery , Peripheral Arterial Disease/therapy , Popliteal Artery , Stents , Adult , Aged , Aged, 80 and over , Amputation, Surgical , Angioplasty, Balloon/adverse effects , Clinical Decision-Making , Female , Femoral Artery/diagnostic imaging , Femoral Artery/physiopathology , Humans , Limb Salvage , Male , Middle Aged , Peripheral Arterial Disease/diagnostic imaging , Peripheral Arterial Disease/physiopathology , Popliteal Artery/diagnostic imaging , Popliteal Artery/physiopathology , Progression-Free Survival , Prospective Studies , Prosthesis Design , Recurrence , Risk Factors , Time Factors , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL
...