Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 91
Filter
1.
Cureus ; 16(5): e61276, 2024 May.
Article in English | MEDLINE | ID: mdl-38947624

ABSTRACT

Gastrointestinal (GI) endoscopies are essential for detecting and treating various digestive tract problems. While typically safe, these treatments can entail the risk of severe adverse events (SAEs), especially in individuals with a low body mass index (BMI). The current study aimed to evaluate whether post-endoscopy SAEs are more common in patients with low BMI and find risk factors for serious adverse outcomes in Saudi Arabian patients from Khamis Mushait, Aseer region, Saudi Arabia. The data of 398 adult patients with abdominal endoscopies between April and November 2023 were analyzed. Patients were divided into two groups: low BMI (BMI ≤ 18.5) and control (18.5 ≤ BMI ≤ 30). They were matched for age, gender, comorbidities, endoscopy type, and other pertinent characteristics. Low-BMI patients (Group I, n = 108) were substantially younger and had lower levels of albumin and total protein than the control group (Group II, n = 209). Comorbidities varied between groups, with diabetes mellitus more prevalent in Group II and inflammatory bowel disease (IBD) more commonplace in Group I. Treatment options also differed, with Group I receiving more biological treatments, steroids, and feeding tubes. Endoscopic procedures and indications were comparable among groups, with no significant variations in post-endoscopy complications. The endoscopy results varied from gastritis to colon malignancy, with no SAEs recorded in either group. Unlike earlier findings, this study found no higher incidence of SAEs in low-BMI individuals having abdominal endoscopy. This might be because of the restricted guidelines of different medical authorities, including clear informed consent that illustrates any risks, benefits, alternatives, sedation plan, and potential diagnostic or therapeutic interventions. Also, professional endoscopists and consultants who ensure adequate visualization of the GI mucosa, using mucosal cleansing and insufflation as necessary, should avoid any risk of abdominal hemorrhage. These findings highlight the significance of personalized risk assessment and pre-procedural optimization, including nutritional assistance, in this patient population. More prospective research with larger sample sizes is needed to validate these findings and create targeted techniques for improving outcomes in individuals with a low BMI having endoscopic operations.

2.
Cureus ; 16(5): e59752, 2024 May.
Article in English | MEDLINE | ID: mdl-38841014

ABSTRACT

The small intestinal diaphragms are a rare condition characterized by focal or diffuse luminal narrowing in the small intestine. Nonsteroidal anti-inflammatory drugs (NSAIDs) have been associated with the development of small intestinal diaphragms, particularly in long-term and high-dose users. In the current report, a Saudi adult female complained of abnormal bowel motions, which caused severe abdominal pain. She had long-term treatment with NSAID. Systemic and physical examination was unremarkable, apart from poorly localized, nonspecific tenderness to abdominal palpation. Two endoscopic investigations (upper and lower endoscopy) were performed to identify any abnormalities in the digestive system; also, a biopsy was taken for histopathological analysis. In addition, another capsule endoscopy was done to investigate any abnormal bowel motion. The findings of two endoscopic investigations and histopathological analysis of duodenum biopsies revealed different features of small intestinal diaphragms and stricture. The biopsies showed mild chronic inflammation. The esophagogastroduodenoscopy (EGD) and colonoscopy showed multiple strictures and ulcerations in the small bowel. Also, a diffused mucosal erythema of the stomach and a remarkable scar on the third part of the duodenum were detected. That might be due to the excessive use of NSAIDs. The investigations revealed multiple small bowel diaphragmatic stenosis and strictures in the proximal and distal small bowel. These are distinct signs of NSAID-induced small bowel diaphragms and strictures.

3.
Med Sci Monit ; 30: e944502, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38857196

ABSTRACT

BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P≤0.05 were considered significant. RESULTS HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 µm). Differences between subgroups for Ra and Rq values were significant (P≤0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. CONCLUSIONS Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.


Subject(s)
Dental Materials , Dental Polishing , Steam , Sterilization , Surface Properties , Zirconium , Sterilization/methods , Humans , Dental Polishing/methods , Materials Testing/methods , Dental Restoration, Permanent/methods , Microscopy, Electron, Scanning/methods
4.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38762747

ABSTRACT

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Subject(s)
Dental Impression Materials , Glutaral , Materials Testing , Polyvinyls , Siloxanes , Dental Impression Materials/chemistry , Polyvinyls/chemistry , Siloxanes/chemistry , Time Factors , Glutaral/chemistry , Dental Disinfectants/chemistry , Sodium Hypochlorite/chemistry , Disinfectants/chemistry , Chlorhexidine/chemistry , Surface Properties , Humans
5.
Thromb J ; 22(1): 43, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38778323

ABSTRACT

BACKGROUND: Recent guidelines recommend using direct oral anticoagulants (DOACs) as first-line agents in patients with non-valvular atrial fibrillation (NVAF). Research is currently investigating the use of Apixaban in underweight patients, with some results suggesting altered pharmacokinetics, decreased drug absorption, and potential overdosing in this population. This study examined the effectiveness and safety of standard Apixaban dosing in adult patients with atrial NVAF weighing less than 50 kg. METHODS: This is a retrospective cohort study conducted at King Abdulaziz Medical City (KAMC); adult patients with a body mass index (BMI) below 25 who received a standard dose of Apixaban (5 mg twice daily) were categorized into two sub-cohorts based on their weight at the time of Apixaban initiation. Underweight was defined as patients weighing ≤ 50 kg, while the control group (Normal weight) comprised patients weighing > 50 kg. We followed the patients for at least one year after Apixaban initiation. The study's primary outcome was the incidence of stroke events, while secondary outcomes included bleeding (major or minor), thrombosis, and venous thromboembolism (VTE). Propensity score (PS) matching with a 1:1 ratio was used based on predefined criteria and regression model was utilized as appropriate. RESULTS: A total of 1,433 patients were screened; of those, 277 were included according to the eligibility criteria. The incidence of stroke events was lower in the underweight than in the normal weight group at crude analysis (0% vs. 9.1%) p-value = 0.06), as well in regression analysis (OR (95%CI): 0.08 (0.001, 0.76), p-value = 0.002). On the other hand, there were no statistically significant differences between the two groups in the odds of major and minor bleeding (OR (95%CI): 0.39 (0.07, 2.03), p-value = 0.26 and OR (95%CI): 1.27 (0.56, 2.84), p-value = 0.40, respectively). CONCLUSION: This exploratory study revealed that underweight patients with NVAF who received standard doses of Apixaban had fewer stroke events compared to normal-weight patients, without statistically significant differences in bleeding events. To confirm these findings, further randomized controlled trials with larger sample sizes and longer observation durations are required.

6.
Clin Case Rep ; 12(4): e8725, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38560282

ABSTRACT

This is a case of 83 years old male who had radial artery pseudoaneurysm after cardiac catheterization. The diagnosis was through Doppler ultrasound and the patient was treated with thrombin injection and reported good outcomes. The literature also included 41 cases of pseudoaneurysm after catheterization. The mean age of patients was 68.5 years with a male prevalence of 49%. Onset of pseudoaneurysm ranged from 0 days (directly after the catheterization) to 150 days with a median of 5 days. The treatment of patients was mainly surgical (19 cases) followed by compression (either manual or TR band) (12 cases), thrombin injection (four cases), compression then surgery (three cases), compression then thrombin injection (one case), percutaneous endovascular repair using a covered stent (one case) and not reported in one case. All cases recovered well.

7.
BMC Oral Health ; 24(1): 495, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38671430

ABSTRACT

BACKGROUND: Dental casts made utilising digital workflow are becoming more common because to their speed and cost savings. However, studies on their dimensional accuracy over time with diverse designs are missing. OBJECTIVE: The aim of this in vitro study was to assess the dimensional stability of 3D-printed edentulous and fully dentate hollowed maxillary models with 50-micrometer resolution over 1 day, 14 days, and 28 days using surface matching software. METHODS: Scanned edentulous and fully dentate maxillary typodont models were used as references. The models were scanned by a desktop lab scanner of 15-micrometer accuracy (D900, 3Shape). Then, the files were used in designing software (Meshmixer, Autodesk) to create hollowed maxillary casts. Fifteen edentulous and 15 fully dentate (total of 30) models were printed using a DLP lab printer (Cara print 4.0, Kulzer). The 3D-printed models were scanned using the same desktop lab scanner of 15-micrometer accuracy at intervals of baseline days, 1 day, 14 days, and 28 days to assess the effect of aging (n = 120). The dimensional changes were quantified and compared using the root mean square (RMS) method, expressed in micrometres (µm). The study employed repeated measures analysis of variance (ANOVA) to assess and compare the root mean square (RMS) values across the variables. The data was analysed using SPSS (26, Chicago, Illinois, USA). RESULTS: The RMS of the edentulous models rapidly increased from a mean value of 0.257 at the beginning of the study to 0.384 after twenty-eight days. However, the mean RMS values for the dentate models did not change much over the four intervals. It varied only from 0.355 to 0.347. The mean values for edentulous patients increased from 0.014 to 0.029 during the period from baseline to twenty-eight days. However, the mean average values decreased for the dentate models from 0.033 to 0.014 during this period. By utilizing ANOVA, mean RMS values increased insignificantly till one day but significantly to fourteen and twenty-eight days. Dentate model mean values differed insignificantly across four intervals. Repeated measures ANOVA for combined and separated data showed no significant differences across edentulous, dentate, and total models over times. CONCLUSION: The study revealed changes in the dimensions of 3D-printed edentulous models over a span of 3 and 4 weeks. Caution should be applied when using 3D-printed dental master models for constructing definitive prostheses on edentulous models over a period of 3 to 4 weeks.


Subject(s)
Maxilla , Models, Dental , Printing, Three-Dimensional , Humans , Maxilla/anatomy & histology , Time Factors , Software , Computer-Aided Design , In Vitro Techniques
8.
Tissue Cell ; 88: 102385, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38678740

ABSTRACT

BACKGROUND: Metabolic syndrome (MetS) is commonly associated with increased risk of cardiac disease that affects a large number of world populations. OBJECTIVE: This research attempted to investigate the efficacy of fennel seeds extract (FSE) in preventing development of cardiac dysfunction in rats on fructose enriched diet for 3 months, as a model of MetS. MATERIALS & METHODS: Thirty adult Wistar male rats (160-170 g) were assigned into 5 groups including control, vehicle, FSE (200 mg/kg BW) and fructose (60%) fed rats with and without FSE. Following the last treatment, blood pressure, ECG and heart rate were measured. Next, blood and cardiac tissues were taken for biochemical and histological investigations. RESULTS: Feeding fructose exhibited characteristic features of MetS involving, hypertension, abnormal ECG, elevated heart rate, serum glucose, insulin, lipids and insulin resistance, accompanied by abdominal obesity, cardiac hypertrophy and hyperuricemia. Fructose fed rats also showed significant reduction in cardiac antioxidants (GSH, SOD, CAT) with elevation in oxidative stress indices (NADPH oxidase, O2.-, H2O2, MDA, PCO), NF-κß, pro-inflammatory cytokines (TNF-α, IL-1ß, IL-6), adhesion molecules (ICAM-1, VCAM-1) and serum cardiac biomarkers (AST, LDH, CK-MB, cTn-I). Histopathological changes evidenced by destruction of cardiac myofibrils, cytoplasmic vacuolization, and aggregation of inflammatory cells were also detected. Consumption of FSE showed high ability to alleviate fructose-induced hypertension, ECG abnormalities, cardiac hypertrophy, metabolic alterations, oxidative stress, inflammation and histological injury. CONCLUSION: Findings could suggest FSE as a complementary supplement for preventing MetS and associated cardiac outcomes. However, well controlled clinical studies are still needed.


Subject(s)
Disease Models, Animal , Foeniculum , Fructose , Hyperuricemia , Inflammation , Metabolic Syndrome , NF-kappa B , Plant Extracts , Rats, Wistar , Seeds , Animals , Metabolic Syndrome/metabolism , Metabolic Syndrome/pathology , Metabolic Syndrome/chemically induced , Metabolic Syndrome/drug therapy , Fructose/adverse effects , Plant Extracts/pharmacology , Male , NF-kappa B/metabolism , Seeds/chemistry , Rats , Hyperuricemia/chemically induced , Hyperuricemia/drug therapy , Foeniculum/chemistry , Inflammation/pathology , Inflammation/metabolism , Oxidative Stress/drug effects , Signal Transduction/drug effects
9.
Pharmacy (Basel) ; 12(1)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38392931

ABSTRACT

INTRODUCTION: One of the main causes of illness, mortality, and rising medical costs is antimicrobial resistance, which is a global healthcare concern. OBJECTIVES: This study explores the practice of physicians toward the effective implementation of Antibiotic Stewardship Programs (ASPs) in Najran city, Saudi Arabia. METHODOLOGY: This cross-sectional study was conducted among physicians working at primary care setting in Najran city, Saudi Arabia, between May and August 2023. A self-administered questionnaire was distributed among the physicians composed of three parts: socio-demographic data, a questionnaire about physicians' practice in the efficacy of ASP, and a questionnaire about physicians' practice regarding prescribing antibiotics. RESULTS: Of the 128 physicians who participated in the study, 60.2% were males, and 43.8% were aged between 36 and 45 years. Among the practices in implementing the ASP effectively, controlling the source of infection domain received the highest score (mean score: 4.83). Every practice domain mean score was greater than 3, indicating that study participants possessed a moderate level of ASP practice and implementation skills. The overall mean practice score in the effective implementation of ASP was 154.9 ± 25.5 out of 185 points, with good, moderate, and poor practices constituting 67.2%, 28.1%, and 4.7%, respectively. CONCLUSIONS: The physicians showed a moderate level of practice for the effective implementation of ASPs in Najran city. The factors significantly associated with increased practice score include older age, male gender, Saudi nationality, handling five or fewer infection cases daily, and infection-initiated antibiotic prescribing treatment managed per day. These findings suggest the need for targeted interventions and educational programs to enhance physicians' adherence to ASP guidelines and promote appropriate antibiotic prescribing practices, ultimately contributing to global efforts in combating antimicrobial resistance and improving patient outcomes.

10.
Breast Cancer Res Treat ; 204(3): 531-538, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38194133

ABSTRACT

PURPOSE: Despite limited evidence supporting its effectiveness, most guidelines recommend long-term, routinely scheduled in-person surveillance of patients with early breast cancer (EBC). The COVID-19 pandemic led to increased use of virtual care. This survey evaluated patient perspectives on follow-up care. METHODS: Patients with EBC undergoing surveillance were surveyed about follow-up protocols, perceptions, and interest in clinical trials assessing different follow-up strategies. RESULTS: Of 402 approached patients 270 completed the survey (response rate 67%). Median age 62.5 years (range 25-86) and median time since breast cancer diagnosis was 3.8 years (range < 1-33 years). Most (n = 148/244, 60%) were followed by more than one provider. Routine follow-ups with breast examination were mostly conducted by medical/radiation oncologists every 6 months (n = 110/236, 46%) or annually (n = 106/236, 44%). Participants felt routine follow-up was useful to monitor for recurrence, manage side effects of cancer treatment and to provide support/reassurance. Most participants felt regular follow-up care would detect recurrent cancer earlier (n = 214/255, 96%) and increase survival (n = 218/249, 88%). The COVID-19 pandemic reduced the number of in-person visits for 54% of patients (n = 63/117). Patients were concerned this reduction of in-person visits would lead to later detection of both local (n = 29/63, 46%) and distant recurrences (n = 25/63, 40%). While many felt their medical and radiation oncologists were the most suited to provide follow-up care, 55% felt comfortable having their primary care provider (PCP) conduct surveillance. When presented with a scenario where follow-up has no effect on earlier detection or survival, 70% of patients still wanted routine in-person follow-up for reassurance (63%) with the goal of earlier recurrence detection (56%). CONCLUSIONS: Despite limited evidence of effectiveness of routine in-person assessment, patients continue to place importance on regularly scheduled in-person follow-up.


Subject(s)
Breast Neoplasms , COVID-19 , Humans , Adult , Middle Aged , Aged , Aged, 80 and over , Female , Breast Neoplasms/diagnosis , Breast Neoplasms/epidemiology , Breast Neoplasms/therapy , Follow-Up Studies , Pandemics , Neoplasm Recurrence, Local/epidemiology , Neoplasm Recurrence, Local/diagnosis , COVID-19/epidemiology
11.
Healthcare (Basel) ; 11(23)2023 Nov 25.
Article in English | MEDLINE | ID: mdl-38063608

ABSTRACT

Rational and responsible self-medication (SM) is an essential core element for better health outcomes. It is influenced mainly by the level and adequacy of knowledge, attitude, and appropriateness of practice (KAP) towards SM. The present study explored the level and adequacy of KAP among residents of Riyadh city, Saudi Arabia. A convenient snowball sampling method was utilized to recruit the study participants. Data were analyzed using SPSS version 27. Six hundred and eleven participants completed the questionnaire. Residents with good knowledge, positive attitude, and proper practice were 43.7%, 33.1%, and 90.0%, respectively. The level of KAP was significantly influenced by the participant's occupation, age, gender, nationality, marital status, presence of chronic disease, and COVID-19 infection status. The mean knowledge, attitude, and practice scores observed were 5.11 (SD = 1.27), 22.28 (SD = 2.6) and 5.20 (SD = 1.29), respectively. Pearson correlation and scattered plot matrix analysis revealed a significant positive weak correlation among KAP, indicating that residents with good knowledge possess better attitude (r = 0.142, p < 0.001) and follow the proper practice (r = 0.256, p < 0.001) towards SM. Multivariate linear regression revealed a significant (p < 0.001) negative (ß = -0.059) influence of occupation, family members working in the health sector (p = 0.046, ß= -0.426), Body Mass Index (p = 0.019, ß = -0.049), and physical activity (p = 0.018, ß = -0.292) on the overall KAP score. Understanding the residents' level of KAP towards SM would enable the health care system to identify the gap and develop a mechanism to educate the people and make them knowledgeable about SM and self-care.

12.
Technol Health Care ; 2023 Oct 26.
Article in English | MEDLINE | ID: mdl-37980583

ABSTRACT

BACKGROUND: Bonding between metal and ceramic is one of the most important aspects of a successful prosthesis. Various methods have been recommended for preparing the metal surface to enhance the bond between metal and ceramic including the use of a metal bonding agent. OBJECTIVE: This study aims to evaluate and compare the shear bond strength of the metal-ceramic (M-C) interface after combinations of various surface treatments including the application of a metal bonding agent. METHOD: 40 Ni-Cr alloy specimens were made and divided into 4 groups of 10 each based on the combination of surface treatments. Sandblasting, surface grinding, and Oxidation heat treatment (OHT) were performed on specimens from Group 1 (Control). In addition, Group 2 specimens received ultrasonic cleaning, Group 3 steam cleaning, and Group 4 metal bonding agent application. Following surface treatments on all specimens, porcelain build-up was performed, and shear bond strength was tested in a Digital Universal testing machine. The statistical tests used were independent t-test and ANOVA. RESULTS: Results revealed that Group 4 specimens had the highest mean value of shear bond strength of 39.087 MPa while Group 3 specimens showed the least mean shear bond strength of 18.154 MPa with highly statistically significant results (p< 0.001). CONCLUSION: The surface treatments and application of bonding agent to metal prior to porcelain application resulted in increased shear bond strength of the metal-ceramic interface.

13.
Med Sci Monit ; 29: e941654, 2023 Nov 04.
Article in English | MEDLINE | ID: mdl-37924203

ABSTRACT

BACKGROUND The aim of this study was to assess and compare the vertical/horizontal dimensions and occlusal accuracy of non-working/opposing casts obtained from three different impression materials and 3D print cast. MATERIAL AND METHODS Dentulous Master models simulating a case of a fixed dental prosthesis were mounted on an articulator (control group). Opposing mandibular casts obtained from three different impression materialsand 3-dimensional print constituted test groups , ,and , respectively. Three points, anterior vertical (AV), posterior vertical (PV), and anteroposterior (AP) were compared for dimensional accuracy among casts. Occlusal accuracy was analyzed on Medit Link software at 3 teeth (#13, #17, and #27). After calculating means for each group, the differences were calculated at probability value of P≤0.05 using the single-sample t test, ANOVA, and Tukey test. RESULTS The dimensions were significantly different from those of the mounted master models except in Gp AL(E) and Gp AL(F) at AV dimension and Gp AL(E) at AP dimension (P>0.05). A statistically significant difference of the error of means among the 4 tested groupswere detected only at 2 dimensions (AV and PV) between the Gp AL(E) and Gp 3D-C and between Gp AL(F) and Gp 3D-C groups. Other groups showed no significant differences. CONCLUSIONS The opposing casts obtained from the extended-pour alginate and alginate alternative impression materials showed higher occlusal accuracy compared to conventional alginate and 3D printed casts.


Subject(s)
Models, Dental , Printing, Three-Dimensional , Humans , Alginates , Mandible , Software
14.
Med Sci Monit Basic Res ; 29: e941919, 2023 Nov 20.
Article in English | MEDLINE | ID: mdl-37987528

ABSTRACT

BACKGROUND Replicating the 3-dimensional (3D) color of natural teeth in artificial substitutes is challenging. Fixed dental prosthodontics require aesthetic, color-stable provisional restorations. Recent milling and 3D printing digital manufacturing techniques offer improved outcomes. This study assesses color stability in various digital manufacturing methods, tapers, and aging effects on anterior provisional resin restorations. MATERIAL AND METHODS Two all-ceramic tooth preparations on typodont teeth with 10° and 20° tapers were converted into experimental dies. Forty temporary crowns were manufactured using 3D printing and computer-aided design/computer-aided manufacturing (milling). Within these 2 groups, 10 crowns were cemented using a regular and clear provisional cement. All samples were thermocycled to simulate clinical use of 6 months. Color difference formula (CIEDE2000) indicated changes between before and after cementation (ΔE00) and between after cementation and after thermocycling (ΔE00[II]). The color change was considered significant in terms of clinically perceptible (ΔE00 ≤0.62) and acceptable (ΔE00 ≤2.62) changes. One-way ANOVA (P value of less than 0.05) calculated overall differences, which were established using a Fisher post hoc test. RESULTS Crowns cemented with clear cement showed fewer color changes irrespective of the manufacturing technique or taper. Notably, only the 10° 3D-printed crown with clear cement had an imperceptible color change at the pre-/post-cementation phase. Meanwhile, the 10° and 20° milled crowns with regular cement exhibited unacceptable color changes after thermocycling. CONCLUSIONS For long­term temporization in the aesthetic zone, properly optimized 3D-printed provisional restorations cemented with clear cement had better color stability.


Subject(s)
Colorimetry , Crowns , Materials Testing , Computer-Aided Design , Glass Ionomer Cements
15.
J Clin Med ; 12(18)2023 Sep 08.
Article in English | MEDLINE | ID: mdl-37762774

ABSTRACT

BACKGROUND: At present, the evidence regarding digital impressions' accuracy recorded by using digital scanners is lacking. This systematic review aimed to evaluate whether the type of scanning (intraoral/extraoral) affects the Accuracy of Digital Impressions. METHOD: Two independent reviewers performed a systematic search in the database both electronically and manually (PubMed, Ebsco HOST, the Cochrane Library, and Google Scholar) for articles published from 1 January 2010 to 1 December 2022. This study was registered with the International Prospective Register of Systematic Reviews (PROSPERO CRD42020188765) and followed the PRISMA statement. The question in focus was as follows: Does the type of scanning (intraoral or extraoral) affect the accuracy of digital impression? RESULTS: A total of 449 papers were obtained by searching electronically and manually. In total, 15 complete-text papers qualified for assessment based on eligibility criteria. After reading the full-text articles, five studies were excluded. Ten studies were selected for the qualitative analysis. The qualitative data reported that the accuracy of both types of scanners (intraoral and extraoral) lies within the range of clinical acceptability. Nevertheless, the intraoral scanners seem to be more accurate when compared to the extraoral scanners for a partial arch situation. CONCLUSIONS: Scanning type affects the accuracy of the digital impression. Various factors influence the scanning ability. Intraoral scanners seem to be more accurate compared to extraoral scanners for a partial arch situation. More studies comparing the accuracy of the intraoral scanner and extraoral scanner for a complete arch scan and in an in vivo study setting are needed.

16.
Curr Oncol ; 30(8): 7508-7519, 2023 08 09.
Article in English | MEDLINE | ID: mdl-37623025

ABSTRACT

(1) Aim: The prevalence and incidence of small bowel NETs have increased significantly over the past two decades. This study aims to report the 10-year experience of SB-NET management at a regional cancer center in Canada. (2) Materials and methods: We conducted a retrospective study of the clinical and pathological data of patients diagnosed with biopsy-proven SB-NET at The Ottawa Hospital (TOH), Ottawa, Canada between 2011 and 2021. We report the clinicopathological characteristics of these patients, as well as their outcomes data, including survival rates. (3) Results: Between 2011 and 2021, a total of 177 SB-NET cases were identified with 51% (n = 91) of cases being males. The most common sites of the tumors were the ileum 53% (n = 94), followed by the duodenum 9% (n = 16) and jejunum 7% (n = 12). Approximately 24% (n = 42) of the patients had symptoms for over six months prior to diagnosis and 18% (n = 32) had functioning SB-NET during the course of the disease. The majority of patients had locally advanced or metastatic disease at the time of presentation with stage III, and stage IV representing 42% (n = 75), and 41% (n = 73) respectively. The majority of patients 84% (n = 148) had well-differentiated histology. One hundred twenty patients underwent surgical resection of the primary tumor including 28 patients (16%) with limited metastatic disease. A total of 21 patients (18%) had recurrence after curative surgery. A total of 62 patients (35%) received first-line somatostatin analog (SSA) therapy for unresectable disease and seven patients had PRRT after progression on SSA. Five years OS was 100%, 91%, 97%, and 73% for stages I, II, III, and IV respectively. In univariate analysis, carcinoid symptoms, T stage, and differentiation were significant predictors for worse overall survival, but not RFS. (4) Conclusions: Compared to published historical controls, our study suggests improvement in the 5-year survival rate of SB-NETs over the last 10 years.


Subject(s)
Intestinal Neoplasms , Neuroendocrine Tumors , Male , Humans , Female , Retrospective Studies , Intestinal Neoplasms/surgery , Hospitals
17.
Support Care Cancer ; 31(9): 529, 2023 Aug 19.
Article in English | MEDLINE | ID: mdl-37597016

ABSTRACT

AIM: Prior to the COVID-19 pandemic, cancer patients would complete their self-reporting health history documentation at their initial consultation visit. With the increase in virtual care, a program was established; whereby, a registered nurse (RN) would complete the self-reporting history with the patient by telephone prior to the initial consultation. A survey of RNs and oncologists evaluating the effectiveness of this program is presented. METHODS: Outpatient RNs and medical and radiation oncologists were surveyed at a single Canadian cancer center. The surveys collected demographic information and perceptions around the successes and challenges of this program. RESULTS: Responses were received from 31/42 (74%) RNs and 29/48 (60%) oncologists. RNs reported calling an average of 4 patients/week, and the median time for each call was 20 min. For responding RNs, 21/31 (68%) felt patients were satisfied with the process, and 18/31 (58%) were satisfied with the quality and efficacy of care they were delivering. 25/31 (81%) RNs felt the telephone calls improved care when the patient came to the clinic. All (100%) oncologists were aware of the program, and 86% (25/29) felt it saved time at the consult visit. Areas for improvement included patients completing the forms themselves and including information on current symptoms and drug insurance status. CONCLUSION: COVID-19 has resulted in many changes in oncology practice. Completion of patient self-reported health history documentation by an RN over the telephone prior to consultation visit received positive feedback from both RNs and oncologists. However, this process has considerable RN resource implications.


Subject(s)
COVID-19 , Pandemics , Humans , Self Report , Canada , Telephone
18.
BMC Oral Health ; 23(1): 564, 2023 08 13.
Article in English | MEDLINE | ID: mdl-37574557

ABSTRACT

BACKGROUND: Developing efficient bonding techniques for orthodontic brackets and all-ceramic materials continues to pose a clinical difficulty. This study aimed to evaluate the shear bond strengths (SBS) of metal and ceramic brackets to various all-ceramic CAD-CAM materials, such as lithium disilicate CAD (LDS-CAD), polymer-infiltrated ceramic (PIC), zirconia-reinforced lithium silicate glass ceramic (ZLS), and 5YTZP zirconia after different surface treatments and thermal cycling. MATERIALS AND METHODS: The samples were divided into two groups to be bonded with ceramic and metal lower incisor brackets. Each group was subdivided into a control group devoid of any surface treatment, 10% HF acid (HFA) etching, ceramic etch & prime (MEP), Al2O3 air abrasion, and medium grit diamond bur roughening. After surface treatment, brackets were bonded with composite resin cement, thermal cycled, and tested for shear bond strength. The failed surfaces were evaluated with a digital microscope to analyse the type of failure. The data were statistically analysed using a one-way ANOVA and Tukey HSD tests at p < 0.05. RESULTS: The highest mean bond strengths were found with HFA etching in LDS-CAD (13.17 ± 0.26 MPa) and ZLS (12.85 0.52 MPa). Diamond bur recorded the lowest mean bond strength roughening across all the ceramic groups. There were significant differences in mean shear bond values per surface treatment (p < 0.001) and ceramic materials. CONCLUSION: Among the surface treatment protocols evaluated, HFA etching and MEP surface treatment resulted in enhanced bond strength of both ceramic and metal brackets to CAD-CAM all ceramic materials.


Subject(s)
Dental Bonding , Orthodontic Brackets , Humans , Air Abrasion, Dental , Dental Bonding/methods , Surface Properties , Ceramics/chemistry , Resin Cements/chemistry , Computer-Aided Design , Diamond , Materials Testing , Shear Strength
19.
Materials (Basel) ; 16(14)2023 Jul 11.
Article in English | MEDLINE | ID: mdl-37512226

ABSTRACT

Increased utilization of all ceramic restorations for aesthetic consideration in combination with routine adult orthodontic practice has led to numerous clinical challenges. Obtaining adequate bond strength between the orthodontic bracket and all-ceramic restoration and damage to the ceramic surface during the bracket debonding procedure needs to be better understood. This study analyzed the surface texture and color change of glazed and bracket-debonded ceramic CAD-CAM materials and the efficiency of porcelain polishing systems in restoring surface morphology and color. A total of 30 rectangular test specimens from each lithium disilicate CAD (LD-CAD), polymer-infiltrated ceramic (PICN), zirconia-reinforced lithium silicate glass ceramic (ZLS), and 5YTZP zirconia (5YZP) were prepared. The ceramic samples were embedded within acrylic resin, and baseline surface roughness and color were recorded using an optical profilometer and a reflected color spectrophotometer. The porcelain samples were bonded with lower incisor ceramic brackets. The samples were thermocycled 2000 times between 5 and 55 °C. Afterward, the brackets were peeled with bracket-removing pliers. The resin adhesive from the debonded surface was eliminated with tungsten carbide bur, and samples were randomly divided into three subgroups of (n = 10) to be polished with Diapol-twist (DT), a Keramik-Politur 4313B Komet polishing kit (KK), and a Horico diamond polisher (HDP). The polished surface roughness and color were recorded. The data were statistically analyzed using a two-way analysis of variance at p < 0.05. The debonded porcelain surfaces across the groups displayed significantly higher mean surface roughness (Ra) compared to glazed surfaces. The debonded 5YZP showed the least Ra at 0.661 (0.09), while the highest Ra was recorded by PICN at 4.057 (0.82). All of the polishing systems evaluated in the study significantly reduced the surface roughness. However, they were unsuccessful in regaining the surface topography of the glazed surface. The flexible discs (DT) produced the smoothest surface, followed by the diamond-impregnated rubber points (KK). Unpolished porcelain surfaces had a discernable mean color difference from glazed surfaces. Polished surfaces from the different polishing systems among the all-ceramic groups achieved a clinically acceptable mean color difference. Polishing debonded rough porcelain surfaces is imperative, and flexible discs performed better in all of the tested CAD-CAM ceramic materials.

20.
Diagnostics (Basel) ; 13(11)2023 May 27.
Article in English | MEDLINE | ID: mdl-37296727

ABSTRACT

A new era in 3-dimensional analysis has begun with the use of cone-beam computed tomography (CBCT) in orthodontics, which promises to provide a more thorough understanding of the craniofacial skeletal architecture. This study aimed to investigate the correlation between the transverse basal arches discrepancy and dental compensation by utilizing CBCT width analysis. An observational study was conducted to retrospectively review 88 CBCT scans of patients presented to dental clinics from 2014 to 2020 obtained from the Planmeca Romexis x-ray system at three centers. Dental compensation data across normal and narrow maxillae were analyzed and a Pearson correlation was used to find the relationship between molar inclination and width difference. Significant maxillary molar compensation differences were observed between the normal maxilla and narrow maxilla group, where the amount of dental compensation (164.73 ± 10.15) was higher in the narrow maxilla group. A significant negative correlation (r = -0.37) was observed between width difference and maxillary molar inclination. Maxillary molars were tipped buccally to compensate for the reduced maxillary arch width. These findings are important to determine the amount of needed maxillary expansion taking into account the buccal inclination while treating cases.

SELECTION OF CITATIONS
SEARCH DETAIL
...