Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Radiology ; 281(3): 835-846, 2016 Dec.
Article in English | MEDLINE | ID: mdl-27479641

ABSTRACT

Purpose To determine the effect of computed tomography (CT) results on physician decision making in three common clinical scenarios in primary care. Materials and Methods This research was approved by the institutional review board (IRB) and was HIPAA compliant. All physicians consented to participate with an opt-in or opt-out mechanism; patient consent was waived with IRB approval. In this prospective multicenter observational study, outpatients referred by primary care providers (PCPs) for CT evaluation of abdominal pain, hematuria, or weight loss were identified. Prior to CT, PCPs were surveyed to elicit their leading diagnosis, confidence in that diagnosis (confidence range, 0%-100%), a rule-out diagnosis, and a management plan if CT were not available. Surveys were repeated after CT. Study measures were the proportion of patients in whom leading diagnoses and management changed (PCP management vs specialist referral vs emergency department transfer), median changes in diagnostic confidence, and the proportion of patients in whom CT addressed rule-out diagnoses. Regression analyses were used to identify associations between study measures and site and participant characteristics. Specifically, logistic regression analysis was used for binary study measures (change in leading diagnosis, change in management), and linear regression analysis was used for the continuous study measure (change in diagnostic confidence). Accrual began on September 5, 2012, and ended on June 28, 2014. Results In total, 91 PCPs completed pre- and post-CT surveys in 373 patients. In patients with abdominal pain, hematuria, or weight loss, leading diagnoses changed after CT in 53% (131 of 246), 49% (36 of 73), and 57% (27 of 47) of patients, respectively. Management changed in 35% (86 of 248), 27% (20 of 74), and 54% (26 of 48) of patients, respectively. Median absolute changes in diagnostic confidence were substantial and significant (+20%, +20%, and +19%, respectively; P ≤ .001 for all); median confidence after CT was high (90%, 88%, and 80%, respectively). PCPs reported CT was helpful in confirming or excluding rule-out diagnoses in 98% (184 of 187), 97% (59 of 61), and 97% (33 of 34) of patients, respectively. Significant associations between primary measures and site and participant characteristics were not identified. Conclusion Changes in PCP leading diagnoses and management after CT were common, and diagnostic confidence increased substantially. © RSNA, 2016 Online supplemental material is available for this article.


Subject(s)
Abdominal Pain/diagnostic imaging , Clinical Decision-Making , Physicians, Primary Care/standards , Adult , Aged , Aged, 80 and over , Clinical Competence/standards , Emergency Medicine/standards , Emergency Service, Hospital/statistics & numerical data , Female , Humans , Male , Middle Aged , Pilot Projects , Prospective Studies , Referral and Consultation/statistics & numerical data , Tomography, X-Ray Computed , Young Adult
2.
AJR Am J Roentgenol ; 201(4): 853-7, 2013 Oct.
Article in English | MEDLINE | ID: mdl-24059375

ABSTRACT

OBJECTIVE: There is considerable interest in improving radiology reporting practices through peer review, and the inclusion of structured feedback from referring physicians may improve this process. The purpose of this article is to evaluate the feasibility of this type of novel peer-review system. MATERIALS AND METHODS: Five referring physicians from our institution participated as reviewers. Reports from abdominal CT, chest CT, brain MRI, and abdominal ultrasound were eligible for review if the indication was "abdominal pain," "shortness of breath," "headache," and "pain," respectively. Reports were excluded if the examinations were normal or ordered as follow-up. Forty-eight reports (12 from each group) were then selected at random and distributed to the referring physicians along with the clinical scenario and an evaluation form for each examination. RESULTS: The reports were found to be clinically useful (average, 3.8 on a 1-5 scale), allowing for good confidence in clinical decision making (average, 3.7). The most common problems were unclear language, typographical errors, and reports that did not answer the clinical question. Of the reports, 35.4% contained recommendations for further diagnosis or treatment, and 84.7% of these recommendations were deemed clinically appropriate. The participating physicians thought that the results of 31.2% of the examinations should have been directly communicated to the ordering provider. CONCLUSION: Radiology reports and recommendations were clinically useful, even though problems with language, typographical errors, answering the clinical question, and direct communication of examination results were identified. Structured feedback from referring physicians is a novel approach to the peer-review process that may identify problems that go unnoticed by the radiologist, thereby improving reporting practices.


Subject(s)
Documentation/standards , Peer Review/standards , Quality Improvement/standards , Radiology/standards , Referral and Consultation/standards , Boston
3.
J Biomed Mater Res A ; 84(2): 464-74, 2008 Feb.
Article in English | MEDLINE | ID: mdl-17618502

ABSTRACT

Aseptic loosening of total joint replacements is believed to be initiated by a macrophage response to prosthetic wear debris. To better characterize the early response to clinically relevant wear debris, we challenged primary human macrophages from four donors with ultra high molecular weight polyethylene (UHMWPE), TiAlV, CoCr, and alumina particles. After a 24-h culture, protein arrays were used to quantify the secretion of 30 different cytokines and chemokines. Macrophages secreted detectable levels of nine mediators in culture: Interleukin-1alpha (IL-1alpha), tumor necrosis factor-alpha (TNF-alpha), IL-1beta, MCP-1, IL-8, IL-6, GM-CSF, IL-10, and IL-12p40. TiAlV particles were the most stimulatory, causing 5- to 900-fold higher cytokine expression compared with nonstimulated cells and uniquely eliciting high levels of IL-1alpha, IL-6, IL-10, and GM-CSF. CoCr and alumina were mildly stimulatory and typically elicited two- to fivefold greater levels than nonstimulated cells. Surprisingly, UHMWPE did not elicit a significant increase in cytokine release. Our data suggests that IL-1alpha, TNF-alpha, IL-1beta, and MCP-1 are the primary initiators of osteolysis and implicates metallic debris as an important trigger for their release.


Subject(s)
Aluminum Oxide/pharmacology , Chromium Alloys/pharmacology , Cytokines/biosynthesis , Macrophages/drug effects , Macrophages/metabolism , Polyethylenes/pharmacology , Titanium/pharmacology , Alloys , Cells, Cultured , Chemokines/biosynthesis , Data Interpretation, Statistical , Humans , In Vitro Techniques , Intercellular Signaling Peptides and Proteins/biosynthesis , Nanoparticles , Particle Size , Particulate Matter , Protein Array Analysis
4.
Biomaterials ; 28(24): 3549-59, 2007 Aug.
Article in English | MEDLINE | ID: mdl-17498799

ABSTRACT

The long-term durability of total joint replacements is critically dependent on adequate peri-implant bone stock, which can be compromised by wear debris-mediated osteolysis. This study investigated the effects of bisphosphonates on enhancing peri-implant bone in the presence of clinically relevant ultra-high molecular weight polyethylene (UHMWPE) wear debris. Fiber-mesh coated titanium-alloy plugs were implanted bilaterally in the femoral condyles of 36 New Zealand white rabbits. Implants in the left femora were covered with submicron UHMWPE particles during surgery. Rabbits were administered either no drug, subcutaneous alendronate weekly (1.0mg/kg/week) or a single dose of intravenous zoledronate (0.015mg/kg). A total of 6/12 rabbits in each group were sacrificed at 6 weeks and the remainder at 12 weeks postoperatively. Peri-implant bone stock was analyzed radiographically and histomorphometrically. Radiographically, both bisphosphonates significantly increased periprosthetic cortical thickness at 6 weeks (p<0.0001; alendronate: +18%; zoledronate: +11%) and at 12 weeks (p=0.001; alendronate: +17%; zoledronate:+19%). Histomorphometrically, alendronate and zoledronate raised peri-implant bone volume (BV/TV) up to 2-fold after 6 weeks without added wear debris and more than 3-fold when wear debris was present. Furthermore a 6-week bisphosphonate treatment increased osteoid thickness in the absence of wear debris (alendronate: +132%, p=0.007; zoledronate: +67%, p=0.51) and in the presence of wear debris (alendronate: +134%, p=0.023; zoledronate: +138%, p=0.016). In summary, alendronate and zoledronate treatment increased periprosthetic bone stock in a rabbit femoral model, particularly in the presence of UHMWPE wear debris. These new findings suggest that bisphosphonates may more than compensate for the well-documented negative effects of wear debris on peri-implant bone stock. The combined antiresorptive and osteoanabolic effects of bisphosphonates on periprosthetic bone stock may have an important role for critically improving the biological fixation and ultimate durability of total joint arthroplasty.


Subject(s)
Anabolic Agents/pharmacology , Bone and Bones/drug effects , Diphosphonates/pharmacology , Animals , Rabbits
SELECTION OF CITATIONS
SEARCH DETAIL
...