Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
1.
Emerg Radiol ; 29(2): 339-352, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34984574

ABSTRACT

PURPOSE: To compare the image quality between a deep learning-based image reconstruction algorithm (DLIR) and an adaptive statistical iterative reconstruction algorithm (ASiR-V) in noncontrast trauma head CT. METHODS: Head CT scans from 94 consecutive trauma patients were included. Images were reconstructed with ASiR-V 50% and the DLIR strengths: low (DLIR-L), medium (DLIR-M), and high (DLIR-H). The image quality was assessed quantitatively and qualitatively and compared between the different reconstruction algorithms. Inter-reader agreement was assessed by weighted kappa. RESULTS: DLIR-M and DLIR-H demonstrated lower image noise (p < 0.001 for all pairwise comparisons), higher SNR of up to 82.9% (p < 0.001), and higher CNR of up to 53.3% (p < 0.001) compared to ASiR-V. DLIR-H outperformed other DLIR strengths (p ranging from < 0.001 to 0.016). DLIR-M outperformed DLIR-L (p < 0.001) and ASiR-V (p < 0.001). The distribution of reader scores for DLIR-M and DLIR-H shifted towards higher scores compared to DLIR-L and ASiR-V. There was a tendency towards higher scores with increasing DLIR strengths. There were fewer non-diagnostic CT series for DLIR-M and DLIR-H compared to ASiR-V and DLIR-L. No images were graded as non-diagnostic for DLIR-H regarding intracranial hemorrhage. The inter-reader agreement was fair-good between the second most and the less experienced reader, poor-moderate between the most and the less experienced reader, and poor-fair between the most and the second most experienced reader. CONCLUSION: The image quality of trauma head CT series reconstructed with DLIR outperformed those reconstructed with ASiR-V. In particular, DLIR-M and DLIR-H demonstrated significantly improved image quality and fewer non-diagnostic images. The improvement in qualitative image quality was greater for the second most and the less experienced readers compared to the most experienced reader.


Subject(s)
Deep Learning , Algorithms , Humans , Image Processing, Computer-Assisted , Radiation Dosage , Radiographic Image Interpretation, Computer-Assisted/methods , Tomography, X-Ray Computed/methods
2.
Diagn Cytopathol ; 49(1): 46-53, 2021 Jan.
Article in English | MEDLINE | ID: mdl-32786062

ABSTRACT

BACKGROUND: Clear-cell chondrosarcomas (CCCSs) constitute a very rare subtype of chondrosarcoma. CCCS may radiologically mimic chondroblastoma, and given the difference in surgical approach, it is important to distinguish these two entities preoperatively. DESIGN: Using the institutional digital records, we identified histologically verified CCCS between 1996 and 2013, where preoperative fine-needle aspiration (FNA) cytology was available. Clinical characteristics were categorized and described, and FNAs were reviewed by a panel of senior cytopathologists. In addition, corresponding radiological imaging was reviewed by senior radiologists, and a literature review on CCCS and chondroblastoma was conducted. RESULTS: A total of seven CCCS FNAs were identified from six patients. The cytomorphology showed low to intermediate cellular smears of clusters and single round or oval tumor cells. Tumor cells had rounded (sometimes binucleated) nuclei with limited pleomorphism and rich vacuolated cytoplasm. Chondroid background matrix was always found. While CCCS patients had a significantly higher age at diagnosis compared to chondroblastoma, no age cut-off would distinctly separate the two. CONCLUSIONS: CCCS has distinguished cytomorphological features on FNA smears. CCCS should be considered as a possible differential diagnosis in adults (>25 years) with a radiological suspicion of chondroblastoma. Since radiology and patient age cannot conclusively distinguish CCCS from chondroblastoma, FNA may prove an important tool for correct preoperative diagnosis of CCCS.


Subject(s)
Bone Neoplasms/diagnosis , Bone Neoplasms/pathology , Chondrosarcoma/diagnosis , Chondrosarcoma/pathology , Adolescent , Adult , Biopsy, Fine-Needle/methods , Chondroblastoma/diagnosis , Chondroblastoma/pathology , Cytodiagnosis/methods , Demography/methods , Diagnosis, Differential , Female , Humans , Male
4.
Skeletal Radiol ; 49(4): 531-539, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31501959

ABSTRACT

OBJECTIVE: The purpose of this study was to assess if ultra-low-dose CT is a useful clinical alternative to digital radiographs in the evaluation of acute wrist and ankle fractures. MATERIALS AND METHODS: An ultra-low-dose protocol was designed on a 256-slice multi-detector CT. Patients from the emergency department were evaluated prospectively. After initial digital radiographs, an ultra-low-dose CT was performed. Two readers independently analyzed the images. Also, the radiation dose, examination time, and time to preliminary report was compared between digital radiographs and CT. RESULTS: In 207 extremities, digital radiography and ultra-low-dose CT detected 73 and 109 fractures, respectively (p < 0.001). The odds ratio for fracture detection with ultra-low-dose CT vs. digital radiography was 2.0 (95% CI, 1.4-3.0). CT detected additional fracture-related findings in 33 cases (15.9%) and confirmed or ruled out suspected fractures in 19 cases (9.2%). The mean effective dose was comparable between ultra-low-dose CT and digital radiography (0.59 ± 0.33 µSv, 95% CI 0.47-0.59 vs. 0.53 ± 0.43 µSv, 95% CI 0.54-0.64). The mean combined examination time plus time to preliminary report was shorter for ultra-low-dose CT compared to digital radiography (7.6 ± 2.5 min, 95% CI 7.1-8.1 vs. 9.8 ± 4.7 min, 95% CI 8.8-10.7) (p = 0.002). The recommended treatment changed in 34 (16.4%) extremities. CONCLUSIONS: Ultra-low-dose CT is a useful alternative to digital radiography for imaging the peripheral skeleton in the acute setting as it detects significantly more fractures and provides additional clinically important information, at a comparable radiation dose. It also provides faster combined examination and reporting times.


Subject(s)
Ankle Fractures/diagnostic imaging , Multidetector Computed Tomography/methods , Radiation Dosage , Wrist Injuries/diagnostic imaging , Acute Disease , Adolescent , Adult , Aged , Aged, 80 and over , Ankle/diagnostic imaging , Extremities/diagnostic imaging , Extremities/injuries , Female , Fractures, Bone/diagnostic imaging , Humans , Male , Middle Aged , Reproducibility of Results , Sensitivity and Specificity , Wrist/diagnostic imaging , Young Adult
5.
J Med Imaging (Bellingham) ; 6(4): 043502, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31620547

ABSTRACT

Photon-counting detectors are expected to bring a range of improvements to patient imaging with x-ray computed tomography (CT). One is higher spatial resolution. We demonstrate the resolution obtained using a commercial CT scanner where the original energy-integrating detector has been replaced by a single-slice, silicon-based, photon-counting detector. This prototype constitutes the first full-field-of-view silicon-based CT scanner capable of patient scanning. First, the pixel response function and focal spot profile are measured and, combining the two, the system modulation transfer function is calculated. Second, the prototype is used to scan a resolution phantom and a skull phantom. The resolution images are compared to images from a state-of-the-art CT scanner. The comparison shows that for the prototype 19 lp / cm are detectable with the same clarity as 14 lp / cm on the reference scanner at equal dose and reconstruction grid, with more line pairs visible with increasing dose and decreasing image pixel size. The high spatial resolution remains evident in the anatomy of the skull phantom and is comparable to that of other photon-counting CT prototypes present in the literature. We conclude that the deep silicon-based detector used in our study could provide improved spatial resolution in patient imaging without increasing the x-ray dose.

6.
Emerg Radiol ; 24(5): 509-518, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28378236

ABSTRACT

PURPOSE: Computed tomography (CT) examinations, often using high-radiation dosages, are increasingly used in the acute management of polytrauma patients. This study compares a low-dose polytrauma multi-phase whole-body CT (WBCT) protocol on a latest generation of 16-cm detector 258-slice multi-detector CT (MDCT) scanner with advanced dose reduction techniques to a single-phase polytrauma WBCT protocol on a 64-slice MDCT scanner. METHODS: Between March and September 2015, 109 polytrauma patients (group A) underwent acute WBCT with a low-dose multi-phase WBCT protocol on a 258-slice MDCT whereas 110 polytrauma patients (group B) underwent single-phase trauma CT on a 64-slice MDCT. The diagnostic accuracy to trauma-related injuries, radiation dose, quantitative and semiquantitative image quality parameters, subjective image quality scorings, and workflow time parameters were compared. RESULTS: In group A, statistically significantly more arterial injuries (p = 0.04) and arterial dissections (p = 0.002) were detected. In group A, the mean (±SD) dose length product value was 1681 ± 183 mGy*cm and markedly lower when compared to group B (p < 0.001). The SDs of the mean Houndsfield unit values of the brain, liver, and abdominal aorta were lower in group A (p < 0.001). Mean signal-to-noise ratios (SNRs) for the brain, liver, and abdominal aorta were significantly higher in group A (p < 0.001). Group A had significantly higher image quality scores for all analyzed anatomical locations (p < 0.02). However, the mean time from patient registration until completion of examination was significantly longer for group A (p < 0.001). CONCLUSIONS: The low-dose multi-phase CT protocol improves diagnostic accuracy and image quality at markedly reduced radiation. However, due to technical complexities and surplus electronic data provided by the newer low-dose technique, examination time increases, which reduces workflow in acute emergency situations.


Subject(s)
Multiple Trauma/diagnostic imaging , Tomography, X-Ray Computed/methods , Whole Body Imaging/methods , Adult , Contrast Media , Female , Humans , Iohexol , Male , Radiation Dosage , Retrospective Studies , Tomography, X-Ray Computed/instrumentation , Whole Body Imaging/instrumentation
7.
Acta Otolaryngol ; 131(8): 802-8, 2011 Aug.
Article in English | MEDLINE | ID: mdl-21480759

ABSTRACT

CONCLUSION: The findings from this study extend the use of the local application of D-methionine (D-met) to protect against acoustic trauma and demonstrate that D-met slowly diffuses from the perilymph. OBJECTIVES: The objectives of the study were to determine the effect of D-met on auditory function and morphology after acoustic trauma and to measure the concentration of D-met in perilymph. METHODS: Auditory thresholds were determine before, immediately after, and 24 h after acoustic trauma. Cochleae were analyzed using immunocytochemistry for c-Fos, TUJI, and cytochrome c. The concentration of D-met was determined from perilymph. RESULTS: Protection against acoustic trauma (immediately and 24 h post trauma) on auditory brainstem thresholds was found at a time when the concentration of D-met in perilymph showed a fivefold increase above basal levels. The local application of D-met to the guinea pig cochlea results in elevated D-met concentrations that are maintained in the perilymph for at least 24 h.


Subject(s)
Ear, Inner/drug effects , Hearing Loss, Noise-Induced/prevention & control , Methionine/administration & dosage , Administration, Topical , Animals , Auditory Threshold/drug effects , Disease Models, Animal , Female , Guinea Pigs , Hearing Loss, Noise-Induced/physiopathology , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...