Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
BJOG ; 130(10): 1167-1176, 2023 09.
Article in English | MEDLINE | ID: mdl-36999234

ABSTRACT

OBJECTIVE: To determine whether the Growth Assessment Protocol (GAP) affects the antenatal detection of large for gestational age (LGA) or maternal and perinatal outcomes amongst LGA babies. DESIGN: Secondary analysis of a pragmatic open randomised cluster control trial comparing the GAP with standard care. SETTING: Eleven UK maternity units. POPULATION: Pregnant women and their LGA babies born at ≥36+0  weeks of gestation. METHODS: Clusters were randomly allocated to GAP implementation or standard care. Data were collected from electronic patient records. Trial arms were compared using summary statistics, with unadjusted and adjusted (two-stage cluster summary approach) differences. MAIN OUTCOME MEASURES: Rate of detection of LGA (estimated fetal weight on ultrasound scan above the 90th centile after 34+0  weeks of gestation, defined by either population or customised growth charts), maternal and perinatal outcomes (e.g. mode of birth, postpartum haemorrhage, severe perineal tears, birthweight and gestational age, neonatal unit admission, perinatal mortality, and neonatal morbidity and mortality). RESULTS: A total of 506 LGA babies were exposed to GAP and 618 babies received standard care. There were no significant differences in the rate of LGA detection (GAP 38.0% vs standard care 48.0%; adjusted effect size -4.9%; 95% CI -20.5, 10.7; p = 0.54), nor in any of the maternal or perinatal outcomes. CONCLUSIONS: The use of GAP did not change the rate of antenatal ultrasound detection of LGA when compared with standard care.


Subject(s)
Parturition , Perinatal Mortality , Infant, Newborn , Infant , Female , Pregnancy , Humans , Gestational Age , Birth Weight , Fetus , Randomized Controlled Trials as Topic
2.
Implement Sci ; 17(1): 60, 2022 09 05.
Article in English | MEDLINE | ID: mdl-36064428

ABSTRACT

BACKGROUND: Reducing the rate of stillbirth is an international priority. At least half of babies stillborn in high-income countries are small for gestational-age (SGA). The Growth Assessment Protocol (GAP), a complex antenatal intervention that aims to increase the rate of antenatal detection of SGA, was evaluated in the DESiGN type 2 hybrid effectiveness-implementation cluster randomised trial (n = 13 clusters). In this paper, we present the trial process evaluation. METHODS: A mixed-methods process evaluation was conducted. Clinical leads and frontline healthcare professionals were interviewed to inform understanding of context (implementing and standard care sites) and GAP implementation (implementing sites). Thematic analysis of interview text used the context and implementation of complex interventions framework to understand acceptability, feasibility, and the impact of context. A review of implementing cluster clinical guidelines, training and maternity records was conducted to assess fidelity, dose and reach. RESULTS: Interviews were conducted with 28 clinical leads and 27 frontline healthcare professionals across 11 sites. Staff at implementing sites generally found GAP to be acceptable but raised issues of feasibility, caused by conflicting demands on resource, and variable beliefs among clinical leaders regarding the intervention value. GAP was implemented with variable fidelity (concordance of local guidelines to GAP was high at two sites, moderate at two and low at one site), all sites achieved the target to train > 75% staff using face-to-face methods, but only one site trained > 75% staff using e-learning methods; a median of 84% (range 78-87%) of women were correctly risk stratified at the five implementing sites. Most sites achieved high scores for reach (median 94%, range 62-98% of women had a customised growth chart), but generally, low scores for dose (median 31%, range 8-53% of low-risk women and median 5%, range 0-17% of high-risk women) were monitored for SGA as recommended. CONCLUSIONS: Implementation of GAP was generally acceptable to staff but with issues of feasibility that are likely to have contributed to variation in implementation strength. Leadership and resourcing are fundamental to effective implementation of clinical service changes, even when such changes are well aligned to policy mandated service-change priorities. TRIAL REGISTRATION: Primary registry and trial identifying number: ISRCTN 67698474. Registered 02/11/16. https://doi.org/10.1186/ISRCTN67698474 .


Subject(s)
Infant, Small for Gestational Age , Stillbirth , Delivery of Health Care , Female , Fetus , Gestational Age , Humans , Infant, Newborn , Pregnancy , Randomized Controlled Trials as Topic , Review Literature as Topic
3.
PLoS Med ; 19(6): e1004004, 2022 06.
Article in English | MEDLINE | ID: mdl-35727800

ABSTRACT

BACKGROUND: Antenatal detection and management of small for gestational age (SGA) is a strategy to reduce stillbirth. Large observational studies provide conflicting results on the effect of the Growth Assessment Protocol (GAP) in relation to detection of SGA and reduction of stillbirth; to the best of our knowledge, there are no reported randomised control trials. Our aim was to determine if GAP improves antenatal detection of SGA compared to standard care. METHODS AND FINDINGS: This was a pragmatic, superiority, 2-arm, parallel group, open, cluster randomised control trial. Maternity units in England were eligible to participate in the study, except if they had already implemented GAP. All women who gave birth in participating clusters (maternity units) during the year prior to randomisation and during the trial (November 2016 to February 2019) were included. Multiple pregnancies, fetal abnormalities or births before 24+1 weeks were excluded. Clusters were randomised to immediate implementation of GAP, an antenatal care package aimed at improving detection of SGA as a means to reduce the rate of stillbirth, or to standard care. Randomisation by random permutation was stratified by time of study inclusion and cluster size. Data were obtained from hospital electronic records for 12 months prerandomisation, the washout period (interval between randomisation and data collection of outcomes), and the outcome period (last 6 months of the study). The primary outcome was ultrasound detection of SGA (estimated fetal weight <10th centile using customised centiles (intervention) or Hadlock centiles (standard care)) confirmed at birth (birthweight <10th centile by both customised and population centiles). Secondary outcomes were maternal and neonatal outcomes, including induction of labour, gestational age at delivery, mode of birth, neonatal morbidity, and stillbirth/perinatal mortality. A 2-stage cluster-summary statistical approach calculated the absolute difference (intervention minus standard care arm) adjusted using the prerandomisation estimate, maternal age, ethnicity, parity, and randomisation strata. Intervention arm clusters that made no attempt to implement GAP were excluded in modified intention to treat (mITT) analysis; full ITT was also reported. Process evaluation assessed implementation fidelity, reach, dose, acceptability, and feasibility. Seven clusters were randomised to GAP and 6 to standard care. Following exclusions, there were 11,096 births exposed to the intervention (5 clusters) and 13,810 exposed to standard care (6 clusters) during the outcome period (mITT analysis). Age, height, and weight were broadly similar between arms, but there were fewer women: of white ethnicity (56.2% versus 62.7%), and in the least deprived quintile of the Index of Multiple Deprivation (7.5% versus 16.5%) in the intervention arm during the outcome period. Antenatal detection of SGA was 25.9% in the intervention and 27.7% in the standard care arm (adjusted difference 2.2%, 95% confidence interval (CI) -6.4% to 10.7%; p = 0.62). Findings were consistent in full ITT analysis. Fidelity and dose of GAP implementation were variable, while a high proportion (88.7%) of women were reached. Use of routinely collected data is both a strength (cost-efficient) and a limitation (occurrence of missing data); the modest number of clusters limits our ability to study small effect sizes. CONCLUSIONS: In this study, we observed no effect of GAP on antenatal detection of SGA compared to standard care. Given variable implementation observed, future studies should incorporate standardised implementation outcomes such as those reported here to determine generalisability of our findings. TRIAL REGISTRATION: This trial is registered with the ISRCTN registry, ISRCTN67698474.


Subject(s)
Fetal Growth Retardation , Infant, Small for Gestational Age , Prenatal Diagnosis , Cluster Analysis , Female , Fetal Growth Retardation/diagnosis , Humans , Infant, Newborn , Pregnancy , Stillbirth
4.
Trials ; 20(1): 154, 2019 Mar 04.
Article in English | MEDLINE | ID: mdl-30832739

ABSTRACT

BACKGROUND: Stillbirth rates in the United Kingdom (UK) are amongst the highest of all developed nations. The association between small-for-gestational-age (SGA) foetuses and stillbirth is well established, and observational studies suggest that improved antenatal detection of SGA babies may halve the stillbirth rate. The Growth Assessment Protocol (GAP) describes a complex intervention that includes risk assessment for SGA and screening using customised fundal-height growth charts. Increased detection of SGA from the use of GAP has been implicated in the reduction of stillbirth rates by 22%, in observational studies of UK regions where GAP uptake was high. This study will be the first randomised controlled trial examining the clinical efficacy, health economics and implementation of the GAP programme in the antenatal detection of SGA. METHODS/DESIGN: In this randomised controlled trial, clusters comprising a maternity unit (or National Health Service Trust) were randomised to either implementation of the GAP programme, or standard care. The primary outcome is the rate of antenatal ultrasound detection of SGA in infants found to be SGA at birth by both population and customised standards, as this is recognised as being the group with highest risk for perinatal morbidity and mortality. Secondary outcomes include antenatal detection of SGA by population centiles, antenatal detection of SGA by customised centiles, short-term maternal and neonatal outcomes, resource use and economic consequences, and a process evaluation of GAP implementation. Qualitative interviews will be performed to assess facilitators and barriers to implementation of GAP. DISCUSSION: This study will be the first to provide data and outcomes from a randomised controlled trial investigating the potential difference between the GAP programme compared to standard care for antenatal ultrasound detection of SGA infants. Accurate information on the performance and service provision requirements of the GAP protocol has the potential to inform national policy decisions on methods to reduce the rate of stillbirth. TRIAL REGISTRATION: Primary registry and trial identifying number: ISRCTN 67698474 . Registered on 2 November 2016.


Subject(s)
Fetal Weight , Infant, Small for Gestational Age , Stillbirth , Ultrasonography, Prenatal , Female , Fetal Development , Gestational Age , Humans , Infant, Newborn , Male , Multicenter Studies as Topic , Pragmatic Clinical Trials as Topic , Predictive Value of Tests , Reproducibility of Results , Risk Factors , United Kingdom
SELECTION OF CITATIONS
SEARCH DETAIL
...