Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 97
Filter
1.
Eur Heart J Case Rep ; 8(2): ytae085, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38405199

ABSTRACT

Background: Ablation of persistent atrial fibrillation (AF) remains challenging, with atrial substrate modification often being performed as an adjunct to pulmonary vein isolation (PVI). Pulsed field ablation (PFA) is a novel ablation modality that carries a favourable safety profile, which could facilitate complex procedures. Case summary: We present the case of a 60-year-old male undergoing catheter ablation for symptomatic persistent AF. The procedure was performed with the Farapulse™ PFA system in a stepwise manner, including PVI and linear lesions for the isolation of the posterior left atrial wall and the ablation of the mitral isthmus. The final step of the procedure included the ablation of areas exhibiting spatiotemporal electrogram dispersion, identified with the help of artificial intelligence-based software (VX1, Volta Medical) in both atria. Sinus rhythm was restored after the abolition of an electrogram dispersion zone in the right atrium. The procedure was carried out without any complications. Discussion: Complex ablation procedures for persistent AF can be successfully performed with PFA. In the context of such extensive ablation strategies, PFA is an attractive energy source, given its non-thermal nature that is known to prevent damage to surrounding tissue and result in less chronic fibrosis. However, caution should be exercised to avoid excessive ablation when using the currently available multispline PFA catheter, as it may inadvertently target adjacent areas of healthy myocardium.

4.
J Interv Card Electrophysiol ; 67(2): 353-361, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37639157

ABSTRACT

BACKGROUND: Ninety-watt applications are more sensitive to catheter instability and produce lesions that are shallower and smaller in diameter than 50-W applications. These characteristics were considered for the development of a combined (90-50 W) pulmonary vein isolation (PVI) strategy which was prospectively compared to a 50 W-only ablation index (AI)-guided PVI strategy. METHODS: One hundred fifty consecutive paroxysmal AF patients underwent PVI under general anesthesia using CARTO. In the first 75 patients, PVI was performed with a combined (90-50 W) strategy using the QDOT-MICRO catheter in a temperature-controlled mode. This strategy consisted of 90 W-4 s applications on the posterior LA wall (at sites of catheter stability and expectedly thin atrial tissue) with an interlesion distance (ILD) ≤ 4 mm and 50-W applications elsewhere (at sites of catheter instability or expectedly thick atrial tissue) with ILD < 6 mm. In the subsequent 75 patients, PVI was performed with a 50 W-only AI-guided strategy using the SmartTouch-SF catheter in a power-controlled mode. RESULTS: Both groups of patients had similar clinical characteristics and LA dimensions (123.1 ± 24.9 ml vs 119 ± 26.8 ml, P = 0.33). Total procedural times (61 [56-70] vs 65 [60-75] min, P = 0.12), first-pass PVI (82.6 vs 80%, P = 0.81), acute PV reconnection (0 vs 6.6%, P = 0.05), and 1-year SR maintenance (93.3 vs 90.6%, P = 0.57) rates were also similar in both groups of patients. There were no complications in the combined (90-50 W) group while only 2 groin hematomas were reported in the 50 W group. CONCLUSIONS: In paroxysmal AF patients, a combined (90-50 W) strategy for PVI did not improve safety, efficiency, or effectiveness compared to a 50 W-only AI-guided strategy.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Pulmonary Veins/surgery , Workflow , Treatment Outcome , Catheter Ablation/adverse effects , Recurrence
5.
Front Cardiovasc Med ; 10: 1194687, 2023.
Article in English | MEDLINE | ID: mdl-37304968

ABSTRACT

Introduction: Apart from pulmonary vein isolation (PVI), several step-by-step procedures that aim to modify left atrial substrate have been proposed for the ablation of persistent atrial fibrillation (AF), yet the optimal strategy remains elusive. There are cumulative data suggesting an incremental benefit of adding vein of Marshall (VOM) ethanol infusion to PVI in patients with persistent AF. We sought to evaluate the feasibility and efficacy of a novel stepwise ablation approach, incorporating a VOM alcoholization step, for persistent AF. Methods: In this single-center study, we prospectively enrolled 66 consecutive patients with symptomatic persistent AF and failure of at least one antiarrhythmic drug (ADD). The ablation procedure consisted of (i) PVI, (ii) left atrial segmentation with VOM ethanol infusion and the deployment of linear radiofrequency lesions across the roof and the mitral isthmus and (iii) electrogram-based ablation of dispersion zones. The first two steps were performed in all patients, whereas the third step was carried out only in those still in AF at the end of the second step. Atrial tachycardias during the procedure were mapped and ablated. At the end of the procedure, cavotricuspid isthmus ablation was additionally performed in all patients. The primary endpoint was 12-month freedom from AF and atrial tachycardia after a single procedure and an initial three-month blanking period. Results: Total procedure time was 153 ± 38.5 min. Fluoroscopy time was 16 ± 6.5 min and the radiofrequency ablation time was 26.14 ± 0.26 min. The primary endpoint occurred in 54 patients (82%). At 12 months, 65% of patients were off any AAD. In the univariate Cox regression analysis, left ventricular ejection fraction < 40% was the only predictor of arrhythmia recurrence (HR 3.56; 95% CI, 1.04-12.19; p = 0.04). One patient developed a pericardial tamponade and another a minor groin hematoma. Conclusion: A novel stepwise approach, including a step of ethanol infusion in the VOM, is feasible, safe and provides a high rate of sinus rhythm maintenance at 12 months in patients with persistent AF.

6.
JACC Clin Electrophysiol ; 9(7 Pt 2): 1070-1081, 2023 07.
Article in English | MEDLINE | ID: mdl-37354173

ABSTRACT

BACKGROUND: Pulsed-field ablation (PFA) is a new and promising modality of ablation that has been shown to specifically ablate cardiac tissue while sparing other anatomic structures, thus avoiding thermal ablation-related complications. Recent studies have certified safety and efficacy of PFA for pulmonary vein isolation (PVI) in the setting of paroxysmal atrial fibrillation (AF). However, there are very limited data assessing the feasibility and safety of PFA ablation of different substrates within the left atrium in the setting of persistent AF. OBJECTIVES: The purpose of this study was to evaluate the feasibility and safety of mitral isthmus (MI) ablation in addition to PVI and posterior wall (PW) ablation with PFA in patients with persistent AF. METHODS: We prospectively included all consecutive patients with persistent AF who underwent a first ablation procedure with PFA. We performed in all these patients a substrate ablation strategy comprising PVI, PW, and MI ablation with the use of PFA only. The primary feasibility endpoint was obtaining a persistent MI block at the end of the procedure. The safety endpoint was a composite of major safety events. RESULTS: From November 2021 to September 2022, we included 45 patients. Complete MI block was achieved in all 45 (100%). Three patients presented with complications, among them 2 cases (4.4%) of reversible and nonfatal coronary spasm. During a mean follow-up time of 107.8 ± 59.5 days, a 20% recurrence rate was observed. CONCLUSIONS: PFA is a feasible and safe ablation approach for mitral isthmus ablation in addition to PVI in patients with persistent AF.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Preliminary Data , Treatment Outcome , Heart Atria , Pulmonary Veins/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods
7.
Front Cardiovasc Med ; 10: 1110165, 2023.
Article in English | MEDLINE | ID: mdl-37051067

ABSTRACT

Introduction: Outcomes of catheter ablation for non-paroxysmal atrial fibrillation (AF) remain suboptimal. Non-invasive stratification of patients based on the presence of atrial cardiomyopathy (ACM) could allow to identify the best responders to pulmonary vein isolation (PVI). Methods: Observational multicentre retrospective study in patients undergoing cryoballoon-PVI for non-paroxysmal AF. The duration of amplified P-wave (APW) was measured from a digitally recorded 12-lead electrocardiogram during the procedure. If patients were in AF, direct-current cardioversion was performed to allow APW measurement in sinus rhythm. An APW cut-off of 150 ms was used to identify patients with significant ACM. We assessed freedom from arrhythmia recurrence at long-term follow-up in patients with APW ≥ 150 ms vs. APW < 150 ms. Results: We included 295 patients (mean age 62.3 ± 10.6), of whom 193 (65.4%) suffered from persistent AF and the remaining 102 (34.6%) from long-standing persistent AF. One-hundred-forty-two patients (50.2%) experienced arrhythmia recurrence during a mean follow-up of 793 ± 604 days. Patients with APW ≥ 150 ms had a significantly higher recurrence rate post ablation compared to those with APW < 150 ms (57.0% vs. 41.6%; log-rank p < 0.001). On a multivariable Cox-regression analysis, APW≥150 ms was the only independent predictor of arrhythmia recurrence post ablation (HR 2.03 CI95% 1.28-3.21; p = 0.002). Conclusion: APW duration predicts arrhythmia recurrence post cryoballoon-PVI in persistent and long-standing persistent AF. An APW cut-off of 150 ms allows to identify patients with significant ACM who have worse outcomes post PVI. Analysis of APW represents an easy, non-invasive and highly reproducible diagnostic tool which allows to identify patients who are the most likely to benefit from PVI-only approach.

8.
J Interv Card Electrophysiol ; 66(2): 343-351, 2023 Mar.
Article in English | MEDLINE | ID: mdl-35581464

ABSTRACT

BACKGROUND: Catheter ablation (CA) technology development reflects the need to improve the effectiveness of atrial fibrillation (AF) treatment. Recently, the DiamondTemp Ablation (DTA) RF generator software was updated with a more responsive power ramp. METHODS: DIAMOND FASTR-AF was a prospective, single-arm, multicenter trial. This study sought to characterize the performance of the updated DTA system for the treatment of patients with drug-refractory paroxysmal and persistent AF (PAF and PsAF). The primary effectiveness endpoint was freedom from atrial arrhythmia recurrence following a 90-day blanking period through 12 months, and the primary safety endpoint was a composite of serious adverse events. RESULTS: In total, 60 subjects (34 PAF and 26 PsAF) underwent CA at three centers. Patients were 71.7% male, (age 63.9 ± 10.2 years, with an AF diagnosis duration 3.1 ± 3.9 years and left atrial size 4.4 ± 0.8 cm). Pulmonary vein isolation-only ablation strategy was performed in 34 (56.7%) subjects. The procedural characteristics show a procedure time 90.8 ± 31.6 min, total RF time 14.7 ± 7.7 min, ablation duration 10.7 ± 3.6 s, and fluid infusion 284.7 ± 111.5 ml. The serious adverse event rate was 8.3% (5/60), 3 pulmonary edema and 2 extended hospitalizations. Freedom from atrial arrhythmia recurrence was achieved in 67.6% of subjects by 12 months. CONCLUSIONS: The updated DTA system demonstrated long-term safety and effectiveness through 12 months of post-ablation follow-up for patients with atrial fibrillation. Additionally, procedures were demonstrated to be highly efficient with short procedure times and low levels of fluid infusion. TRIAL REGISTRATION: Sponsored by Medtronic, Inc.; FASTR-AF ClinicalTrials.gov; NCT03626649.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Male , Middle Aged , Aged , Female , Atrial Fibrillation/surgery , Prospective Studies , Temperature , Treatment Outcome , Catheter Ablation/methods , Pulmonary Veins/surgery , Recurrence
9.
J Cardiovasc Electrophysiol ; 34(2): 270-278, 2023 02.
Article in English | MEDLINE | ID: mdl-36434797

ABSTRACT

INTRODUCTION: Pulmonary vein isolation (PVI) is effective at treating 50% of unselected patients with persistent atrial fibrillation (AF). Alternatively, PVI combined with a new ablation strategy entitled the Marshall-PLAN ensures a 78% 1-year sinus rhythm (SR) maintenance rate in the same population. However, a substantial subset of patients could undergo the Marshall-PLAN unnecessarily. It is therefore essential to identify those patients who can be treated with PVI alone versus those who may truly benefit from the Marshall-PLAN before ablation is performed. In this context, we hypothesized that electrical cardioversion (EC) could help to select the most appropriate strategy for each patient. METHODS: In this multicentre, prospective, randomized study, patients with AF recurrence within 4 weeks after EC will be randomized 1:1 to PVI alone or the Marshall-PLAN. Conversely, patients in whom SR is maintained for ≥4 weeks after EC will be treated with PVI only and included in a prospective registry. The primary endpoint will be the 1-year SR maintenance rate after a single ablation procedure. RESULTS AND CONCLUSION: The Marshall-PLAN might be necessary in patients with an advanced degree of persistent AF (i.e., where SR is not maintained for ≥4 uninterrupted weeks after EC). Conversely, in patients with mild or moderate persistent AF (i.e., where SR is maintained for ≥4 weeks after EC), PVI alone might be a sufficient ablation strategy. The PACIFIC trial is the first study designed to assess whether rhythm monitoring after EC could help to identify patients who should undergo adjunctive ablation strategies beyond PVI.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Pulmonary Veins/surgery , Electric Countershock/adverse effects , Treatment Outcome , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
12.
Circ Arrhythm Electrophysiol ; 15(4): e010663, 2022 04.
Article in English | MEDLINE | ID: mdl-35363039

ABSTRACT

BACKGROUND: Fifty-watt radiofrequency applications have proven to be safe and efficient for pulmonary vein isolation (PVI). However, as PV reconnection still occurs and ablation catheter instability significantly contributes to suboptimal lesion formation, a new ablation catheter capable of delivering 90 W for 4 seconds only has been developed with the aim of improving PVI outcomes. In this setting, we sought to determine whether 90 W applications create transmural lesions without collateral damage experimentally and whether they can safely improve PVI procedures clinically compared with 50 W settings. METHODS: Experimentally, individual lesions were created in vivo in the right atrium of 6 swine with 90 W-4 seconds applications using the SmartTouch-SF catheter in a power-controlled mode (3 animals) or the QDOT-MICRO catheter in a temperature-controlled mode (3 animals). Clinically, PVI was performed in a homogenous population of 150 consecutive paroxysmal atrial fibrillation patients using CARTO and the QDOT-MICRO catheter in a temperature-controlled mode (75 patients 50 W-ablation index-guided and 75 patients 90 W-4 seconds). RESULTS: Mostly, (94.9%) experimental lesions were transmural in the thin-walled right atrium of swine. However, collateral damage was observed with both catheters in 17.9% of lesions. Clinically, 90 W procedures had a lower first-pass PVI rate (49% versus 81%, P<10-4) and a higher acute PV reconnection rate (21% versus 5%, P=0.004) than 50 W procedures, whereas total procedural duration (62 versus 66 minutes, P=0.09), 1-year sinus rhythm maintenance (88% versus 90%, P=0.6) and safety (1 tamponade per group) were similar in both groups. CONCLUSIONS: Experimentally, using the QDOT-MICRO catheter, 90 W-4 seconds lesions are mostly transmural in the thin-walled right atrium of swine (median depth 1.87 mm) with a moderate lesion diameter of 6.62 mm but retain the potential for collateral damage. Clinically, 90 W-4 seconds applications are associated with a lower first-pass PVI rate and a higher acute PV reconnection rate than 50 W applications but similar safety outcomes and effectiveness at 1 year.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Animals , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Catheters , Heart Atria/surgery , Humans , Pulmonary Veins/surgery , Recurrence , Swine , Treatment Outcome
13.
Clin Res Cardiol ; 111(9): 1018-1027, 2022 Sep.
Article in English | MEDLINE | ID: mdl-34854991

ABSTRACT

AIMS: Despite advances in interventional treatment strategies, atrial fibrillation (AF) remains associated with significant morbidity and mortality. Fibrotic atrial myopathy (FAM) is a main factor for adverse outcomes of AF-ablation, but complex to diagnose using current methods. We aimed to derive a scoring system based entirely on easily available clinical parameters to predict FAM and ablation-success in everyday care. METHODS: In this multicenter, prospective study, a new risk stratification model termed AF-SCORE was derived in 220 patients undergoing high-density left-atrial(LA) voltage-mapping to quantify FAM. AF-SCORE was validated for FAM in an external mapping-validation cohort (n = 220) and for success following pulmonary vein isolation (PVI)-only (without adjunctive left- or right atrial ablations) in an external outcome-validation cohort (n = 518). RESULTS: FAM was rare in patients < 60 years (5.4%), but increased with ageing and affected 40.4% (59/146) of patients ≥ 60 years. Sex and AF-phenotype had additional predictive value in older patients and remained associated with FAM in multivariate models (odds ratio [OR] 6.194, p < 0.0001 for ≥ 60 years; OR 2.863, p < 0.0001 for female sex; OR 41.309, p < 0.0001 for AF-persistency). Additional clinical or diagnostic variables did not improve the model. AF-SCORE (+ 1 point for age ≥ 60 years and additional points for female sex [+ 1] and AF-persistency [+ 2]) showed good discrimination to detect FAM (c-statistic 0.792) and predicted arrhythmia-freedom following PVI (74.3%, 54.7% and 45.5% for AF-SCORE ≤ 2, 3 and 4, respectively, and hazard ratio [HR] 1.994 for AF-SCORE = 3 and HR 2.866 for AF-SCORE = 4, p < 0.001). CONCLUSIONS: Age, sex and AF-phenotype are the main determinants for the development of FAM. A low AF-SCORE ≤ 2 is found in paroxysmal AF-patients of any age and younger patients with persistent AF irrespective of sex, and associated with favorable outcomes of PVI-only. Freedom from arrhythmia remains unsatisfactory with AF-SCORE ≥ 3 as found in older patients, particularly females, with persistent AF, and future studies investigating adjunctive atrial ablations to PVI-only should focus on these groups of patients.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiomyopathies/etiology , Catheter Ablation/adverse effects , Catheter Ablation/methods , Female , Fibrosis , Humans , Prospective Studies , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
14.
J Interv Card Electrophysiol ; 64(2): 375-381, 2022 Aug.
Article in English | MEDLINE | ID: mdl-34089431

ABSTRACT

BACKGROUND AND PURPOSE: Saline-irrigated radiofrequency ablation (RFA) for atrial fibrillation (AF) is limited by the absence of reliable thermal feedback limiting the utility of temperature monitoring for power titration. The DiamondTemp (DT) ablation catheter was designed to allow efficient temperature-controlled irrigated ablation. We sought to assess the 1-year clinical safety and efficacy of the DT catheter in treating drug-refractory paroxysmal AF. METHODS: The TRAC-AF trial (NCT02821351) is a prospective, multi-center (n = 4), single-arm study which enrolled patients with symptomatic, drug-refractory, paroxysmal AF. Using the DT catheter, point-by-point ablation was performed around all pulmonary veins (PVs) to achieve PV isolation (PVI). Ablation was performed in a temperature-controlled mode (60 °C, max 50 W). Acute and chronic efficacy and safety was evaluated. RESULTS: Seventy-one patients (age 69.9 ± 11.0 years; 60.6% male) were ablated using the DT catheter. The mean fluoroscopy and RF ablation times were 9.3 ± 6.1 min and 20.6 ± 8.9 min, respectively. Acute isolation of all PVs was achieved in 100% of patients, and freedom from AF after 1 year was 70.6%. There were no steam pops, char, or coagulum on the catheter tip after ablation. There were few serious procedure/device-related adverse events including a single case of cardiac tamponade (1.4%) and transient ischemic attack (1.4). CONCLUSION: This first in man series demonstrates that temperature-controlled irrigated RFA with the DT catheter is efficient, safe, and effective in the treatment of paroxysmal AF. Randomized controlled trials are ongoing and will evaluate better the role of this catheter in relation to standard RFA. TRIAL REGISTRATION: Registered on the site ClinicalTrials.gov January 2016 with identifier: NCT02821351.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Aged , Aged, 80 and over , Catheter Ablation/adverse effects , Equipment Design , Female , Humans , Male , Middle Aged , Prospective Studies , Pulmonary Veins/surgery , Temperature , Treatment Outcome
16.
Heart ; 107(16): 1296-1302, 2021 08.
Article in English | MEDLINE | ID: mdl-33952593

ABSTRACT

OBJECTIVE: Pulmonary vein isolation (PVI) guided by a standardised CLOSE (contiguous optimised lesions) protocol has been shown to increase clinical success after catheter ablation for paroxysmal atrial fibrillation (PAF). This study analysed healthcare utilisation and quality of life (QOL) outcomes from a large multicentre prospective study, measured association between QOL and atrial fibrillation (AF) burden and identified factors associated with lack of QOL improvement. METHODS: CLOSE-guided ablation was performed in 329 consecutive patients (age 61.4 years, 60.8% male) with drug-refractory PAF in 17 European centres. QOL was measured at baseline and 12 months post-ablation via Atrial Fibrillation Effect on QualiTy of Life Survey (AFEQT) and EuroQoL EQ-5D-5L questionnaires. All-cause and cardiovascular hospitalisations and cardioversions over 12 months pre-ablation and post-ablation were recorded. Rhythm monitoring included weekly and symptom-driven trans-telephonic monitoring, plus ECG and Holter monitoring at 3, 6 and 12 months. AF burden was defined as the percentage of postblanking tracings with an atrial tachyarrhythmia ≥30 s. Continuous measures across multiple time points were analysed using paired t-tests, and associations between various continuous measures were analysed using independent sample t-tests. Each statistical test used two-sided p values with a significance level of 0.05. RESULTS: Both QOL instruments showed significant 12-month improvements across all domains: AFEQT score increased 25.1-37.5 points and 33.3%-50.8% fewer patients reporting any problem across EuroQoL EQ-5D-5L domains. Overall, AFEQT improvement was highly associated with AF burden (p=0.009 for <10% vs ≥10% burden, p<0.001 for <20% vs ≥20% burden). Cardiovascular hospitalisations were significantly decreased after ablation (42%, p=0.001). Patients without substantial improvement in AFEQT (55/301, 18.2%) had higher AFEQT and CHA2DS2-VASc scores at baseline, and higher AF burden following PVI. CONCLUSIONS: QOL improved and healthcare utilisation decreased significantly after ablation with a standardised CLOSE protocol. QOL improvement was significantly associated with impairment at baseline and AF burden after ablation. TRIAL REGISTRATION NUMBER: NCT03062046.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Patient Acceptance of Health Care/statistics & numerical data , Pulmonary Veins/surgery , Quality of Life , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/psychology , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Cost of Illness , Electric Countershock/statistics & numerical data , Electrocardiography, Ambulatory/methods , Electrocardiography, Ambulatory/statistics & numerical data , Europe/epidemiology , Female , Hospitalization/statistics & numerical data , Humans , Male , Middle Aged , Outcome Assessment, Health Care , Perioperative Period/psychology , Perioperative Period/statistics & numerical data , Surveys and Questionnaires
17.
J Cardiovasc Electrophysiol ; 32(6): 1584-1593, 2021 06.
Article in English | MEDLINE | ID: mdl-33772926

ABSTRACT

BACKGROUND: The assessment of noninvasive markers of left atrial (LA) low-voltage substrate (LVS) enables the identification of atrial fibrillation (AF) patients at risk for arrhythmia recurrence after pulmonary vein isolation (PVI). METHODS: In this prospective multicenter study, 292 consecutive AF patients (72% male, 62 ± 11 years, 65% persistent AF) underwent high-density LA voltage mapping in sinus rhythm. LA-LVS (<0.5 mV) was considered as significant at 2 cm2  or above. Preprocedural clinical electrocardiogram and echocardiographic data were assessed to identify predictors of LA-LVS. The role of the identified LA-LVS markers in predicting 1-year arrhythmia freedom after PVI was assessed in 245 patients. RESULTS: Significant LA-LVS was identified in 123 (42%) patients. The amplified sinus P-wave duration (APWD) best predicted LA-LVS, with a 148-ms value providing the best-balanced sensitivity (0.81) and specificity (0.88). An APWD over 160 ms was associated with LA-LVS in 96% of patients, whereas an APWD under 145 ms in 15%. Remaining gray zones improved their accuracy by introduction of systolic pulmonary artery pressure (sPAP) of 35 mmHg or above, age, and sex. According to COX regression, the risk of arrhythmia recurrence 12 months following PVI was twofold and threefold higher in patients with APWD 145-160 and over 160 ms, compared to APWD under 145 ms. Integration of pulmonary hypertension further improved the outcome prediction in the intermediate APWD group: Patients with APWD 145-160 ms and normal sPAP had similar outcome than patients with APWD under 145 ms (hazard ratio [HR] 1.62, p = .14), whereas high sPAP implied worse outcome (HR 2.56, p < .001). CONCLUSIONS: The APWD identifies LA-LVS and risk for arrhythmia recurrence after PVI. Our prediction model becomes optimized by means of integration of the pulmonary artery pressure.


Subject(s)
Atrial Fibrillation , Atrial Remodeling , Catheter Ablation , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Echocardiography , Electrocardiography , Female , Heart Atria/diagnostic imaging , Humans , Male , Prospective Studies , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
19.
JACC Clin Electrophysiol ; 7(3): 352-363, 2021 03.
Article in English | MEDLINE | ID: mdl-33516712

ABSTRACT

OBJECTIVES: DIAMOND-AF (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation) was a prospective, multicenter, noninferiority, randomized trial that compared the safety and effectiveness of the DTA system versus those of a force-sensing RF ablation system (control) for the treatment of patients with drug-refractory, recurrent, symptomatic paroxysmal atrial fibrillation (AF). BACKGROUND: Irrigated radiofrequency (RF) ablation catheters lose tissue temperature acuity, which is vital in assessing lesion formation. DiamondTemp Ablation (DTA) was designed to re-establish accurate tissue temperature measurements during ablation. METHODS: A total of 482 patients with paroxysmal AF were randomized (239 DTA, 243 control) to undergo pulmonary vein isolation and were followed up at 23 sites. Patients were screened for disease progression, cardiac characteristics, and prior interventions. Primary endpoints were effectiveness (freedom from atrial arrhythmia recurrence) and safety (composite of procedure- and device-related serious adverse events). RESULTS: The primary safety event rate was 3.3% in the DTA group versus 6.6% in the control group (p < 0.001 vs. 6.5% noninferiority margin). Primary effectiveness was met in 79.1% of DTA subjects and 75.7% of control subjects (p < 0.001 vs. -12.5% noninferiority margin). Secondary endpoint analysis found that off-drug effectiveness favored DTA compared with the control (142 [59.4%] vs. 120 [49.4%], respectively; p = 0.03). Total RF time and individual RF ablation duration were significantly shorter with less saline infused through the DTA catheter (p < 0.001). Both arms saw clinically meaningful improvements in quality of life at 12 months. CONCLUSIONS: Safety and efficacy of the DTA system proved noninferior to force-sensing RF ablation in a paroxysmal AF population. Efficiencies were observed using DTA with shorter total RF times, individual RF ablation durations, and less saline infusion. (DiamondTemp™ Ablation System for the Treatment of Paroxysmal Atrial Fibrillation; NCT03334630).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/surgery , Catheter Ablation/adverse effects , Catheters , Humans , Prospective Studies , Quality of Life , Temperature , Treatment Outcome
20.
JAMA Netw Open ; 3(12): e2025473, 2020 12 01.
Article in English | MEDLINE | ID: mdl-33275151

ABSTRACT

Importance: Catheter ablation is effective in reducing atrial fibrillation (AF), but the association of ablation for AF with quality of life is unclear. Objective: To evaluate whether the procedural outcome of ablation for AF is associated with quality of life (QOL) measures. Design, Setting, and Participants: This was a prespecified secondary analysis of the Substrate and Trigger Ablation for Reduction of Atrial Fibrillation-Part II (STAR AF II) prospective randomized clinical trial, which compared 3 strategies for ablation of persistent AF. This analysis included 549 of the 589 patients enrolled in the trial who underwent ablation. Enrollment occurred at 35 centers in Europe, Canada, Australia, China, and Korea from November 2010 to July 2012. Data for the current study were analyzed on December 11, 2019. Interventions: Patients underwent AF ablation with 1 of 3 ablation strategies: (1) pulmonary vein isolation (PVI), (2) PVI plus complex fractionated electrograms, or (3) PVI plus linear lesions. Main Outcomes and Measures: Quality of life was assessed at baseline and at 6, 12, and 18 months after ablation for AF using the 36-Item Short Form Health Survey and the EuroQol Health-Related Quality of Life 5-Dimension 3-Level questionnaire. Scores were also converted to a physical health component score (PCS) and a mental health component score (MCS). Individual AF burden was calculated by the total time with AF from Holter monitors and the percentage of transtelephonic monitor recordings showing AF. Results: Among the 549 patients included in this secondary analysis, QOL was assessed in 466 (85%) at baseline and at 6, 12, and 18 months after ablation for AF. The mean (SD) age of the study population was 60 (9) years; 434 (79%) individuals were men, and 417 (76%) had continuous AF for 6 months or more before ablation. The AF burden significantly decreased from a mean (SD) of 82% (36%) before ablation to 6.6% (23%) after ablation (P < .001). Significant improvements in mean (SD) PCS (68.3 [20.7] to 82.5 [18.6]) and MCS (35.3 [8.6] to 37.5 [7.6]) occurred 18 months after ablation (P < .05 for both). Significant QOL improvement occurred in all 3 study arms and regardless of AF recurrence, defined as AF episodes lasting more than 30 seconds: for no recurrence, mean (SD) PCS increased from 66.5 (20.9) to 79.1 (19.4) and MCS from 35.3 (8.7) to 37.7 (7.7); for recurrence, mean (SD) PCS increased from 70.2 (20.4) to 86.4 (16.8) and MCS from 35.3 (8.6) to 37.1 (7.4) (P < .05 for all). When outcome was defined by AF burden reduction, in patients with less than 70% reduction in AF burden, the increase in PCS was significantly less than in those with greater than 70% reduction, and only 3 of 8 subscales showed significant improvement. Conclusions and Relevance: In this secondary analysis, decreases in AF burden after ablation for AF were significantly associated with improvements in QOL. Quality of life changes were significantly associated with the percentage of AF burden reduction after ablation. Trial Registration: ClinicalTrials.gov Identifier: NCT01203748.


Subject(s)
Atrial Fibrillation/epidemiology , Atrial Fibrillation/surgery , Catheter Ablation , Quality of Life , Atrial Fibrillation/psychology , Australia/epidemiology , Canada/epidemiology , Catheter Ablation/methods , Catheter Ablation/psychology , China/epidemiology , Europe/epidemiology , Female , Health Surveys , Humans , Quality of Life/psychology , Randomized Controlled Trials as Topic , Republic of Korea/epidemiology , Treatment Outcome
SELECTION OF CITATIONS