Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 11(1): 21449, 2021 11 02.
Article in English | MEDLINE | ID: mdl-34728650

ABSTRACT

The World Health Organisation has called for a 40% increase in personal protective equipment manufacturing worldwide, recognising that frontline workers need effective protection during the COVID-19 pandemic. Current devices suffer from high fit-failure rates leaving significant proportions of users exposed to risk of viral infection. Driven by non-contact, portable, and widely available 3D scanning technologies, a workflow is presented whereby a user's face is rapidly categorised using relevant facial parameters. Device design is then directed down either a semi-customised or fully-customised route. Semi-customised designs use the extracted eye-to-chin distance to categorise users in to pre-determined size brackets established via a cohort of 200 participants encompassing 87.5% of the cohort. The user's nasal profile is approximated to a Gaussian curve to further refine the selection in to one of three subsets. Flexible silicone provides the facial interface accommodating minor mismatches between true nasal profile and the approximation, maintaining a good seal in this challenging region. Critically, users with outlying facial parameters are flagged for the fully-customised route whereby the silicone interface is mapped to 3D scan data. These two approaches allow for large scale manufacture of a limited number of design variations, currently nine through the semi-customised approach, whilst ensuring effective device fit. Furthermore, labour-intensive fully-customised designs are targeted as those users who will most greatly benefit. By encompassing both approaches, the presented workflow balances manufacturing scale-up feasibility with the diverse range of users to provide well-fitting devices as widely as possible. Novel flow visualisation on a model face is presented alongside qualitative fit-testing of prototype devices to support the workflow methodology.


Subject(s)
Face/physiology , Personal Protective Equipment , Photogrammetry/methods , COVID-19/prevention & control , COVID-19/virology , Computer-Aided Design , Equipment Design , Face/anatomy & histology , Humans , Printing, Three-Dimensional , SARS-CoV-2/isolation & purification
2.
Ultrason Sonochem ; 48: 218-230, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30080545

ABSTRACT

Acoustic streaming phenomena of ultrasound propagation through liquid media was investigated experimentally employing particle image velocimetry (PIV). Parameters associated with the ultrasonic processor of ultrasonic amplitude (i.e., acoustic power) and transducer tip diameter (i.e., surface area), as well as, fluid rheology (i.e., water, glycerol solution and CMC solution), were studied for their effects on overall flow behaviour and fluid velocity. PIV yielded velocity gradient maps, demonstrating the acoustic streaming phenomena of ultrasound and its associated flow behaviour as a function of ultrasonic amplitude and fluid rheology, whereby increasing amplitude allowed for greater penetration of the acoustic-beam through the bulk of the fluid, and increasing fluid rheology yielded the converse effect. Moreover, upon impingement of the acoustic-beam with the base of vessel, vortex formation occurred, yielding a recirculation pattern. The maximum observed fluid velocities for water, glycerol solution and CMC solution were 0.329 m s-1, 0.423 m s-1, and 0.304 m s-1, respectively (large diameter sonotrode tip for an ultrasonic amplitude of 80%). Furthermore, shear rates were attained (maximum values of 24.25 s-1), and Reynolds numbers were determined in order to assess the degree of turbulence as a function of investigated parameters.

3.
Int J Pharm ; 495(1): 362-373, 2015 Nov 10.
Article in English | MEDLINE | ID: mdl-26363111

ABSTRACT

In this study, planar induced fluorescence (PLIF) was used for the first time to evaluate variability in drug dissolution data using Rhodamine-6G doped tablets within small volume USP 2 apparatus. The results were compared with tablets contained theophylline (THE) drug for conventional dissolution analysis. The impact of hydrodynamics, sampling point, dissolution media viscosity and pH were investigated to note effects on release of these two actives from the hydrophilic matrix tablets. As expected mixing performance was poor with complex and reduced velocities at the bottom of the vessel close to the tablet surface; this mixing became even worse as the viscosity of the fluid increased. The sampling point for dissolution can affect the results due to in-homogenous mixing within the vessel; this effect is exacerbated with higher viscosity dissolution fluids. The dissolution profiles of RH-6G measured via PLIF and THE measured using UV analysis were not statistically different demonstrating that RH-6G is an appropriate probe to mimic the release profile of a highly soluble drug. A linear correlation was accomplished between the release data of the drug and the dye (R(2)>0.9). The dissolution profile of the dye, obtained with the analysis of the PLIF images, can be used in order to evaluate how the viscosity and the mixing performance of USP 2 mini vessel affect the interpretation of the dissolution data of the targeted drug.


Subject(s)
Chemistry, Pharmaceutical/instrumentation , Drug Liberation , Hydrodynamics , Tablets/chemistry , Viscosity , Carboxymethylcellulose Sodium/chemistry , Hydrogen-Ion Concentration , Hydrophobic and Hydrophilic Interactions , Rhodamines/chemistry , Solubility , Theophylline/chemistry
4.
Water Res ; 85: 497-511, 2015 Nov 15.
Article in English | MEDLINE | ID: mdl-26379205

ABSTRACT

A novel Euler-Lagrangian (EL) computational fluid dynamics (CFD) finite volume-based model to simulate the gas mixing of sludge for anaerobic digestion is developed and described. Fluid motion is driven by momentum transfer from bubbles to liquid. Model validation is undertaken by assessing the flow field in a labscale model with particle image velocimetry (PIV). Conclusions are drawn about the upscaling and applicability of the model to full-scale problems, and recommendations are given for optimum application.


Subject(s)
Rheology/methods , Anaerobiosis , Bioreactors , Gases , Hydrodynamics , Models, Theoretical
SELECTION OF CITATIONS
SEARCH DETAIL
...