Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Nature ; 600(7889): 434-438, 2021 12.
Article in English | MEDLINE | ID: mdl-34912088

ABSTRACT

Quantum emitters respond to resonant illumination by radiating part of the absorbed energy. A component of this radiation field is phase coherent with the driving tone, whereas another component is incoherent and consists of spontaneously emitted photons, forming the fluorescence signal1. Atoms, molecules and colour centres are routinely detected by their fluorescence at optical frequencies, with important applications in quantum technology2,3 and microscopy4-7. By contrast, electron spins are usually detected by the phase-coherent echoes that they emit in response to microwave driving pulses8. The incoherent part of their radiation-a stream of microwave photons spontaneously emitted upon individual spin relaxation events-has not been observed so far because of the low spin radiative decay rate and of the lack of single microwave photon detectors (SMPDs). Here using superconducting quantum devices, we demonstrate the detection of a small ensemble of donor spins in silicon by their fluorescence at microwave frequencies and millikelvin temperatures. We enhance their radiative decay rate by coupling them to a high-quality-factor and small-mode-volume superconducting resonator9, and we connect the device output to a newly developed SMPD10 based on a superconducting qubit. In addition, we show that the SMPD can be used to detect spin echoes and that standard spin characterization measurements (Rabi nutation and spectroscopy) can be achieved with both echo and fluorescence detection. We discuss the potential of SMPD detection as a method for magnetic resonance spectroscopy of small numbers of spins.

2.
J Magn Reson ; 303: 42-47, 2019 Jun.
Article in English | MEDLINE | ID: mdl-31003062

ABSTRACT

In high sensitivity inductive electron spin resonance spectroscopy, superconducting microwave resonators with large quality factors are employed. While they enhance the sensitivity, they also distort considerably the shape of the applied rectangular microwave control pulses, which limits the degree of control over the spin ensemble. Here, we employ shaped microwave pulses compensating the signal distortion to drive the spins faster than the resonator bandwidth. This translates into a shorter echo, with enhanced signal-to-noise ratio. The shaped pulses are also useful to minimize the dead-time of our spectrometer, which allows to reduce the wait time between successive drive pulses.

SELECTION OF CITATIONS
SEARCH DETAIL
...