Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Language
Publication year range
1.
Braz. J. Pharm. Sci. (Online) ; 56: e17344, 2020. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1089212

ABSTRACT

Piroxicam (PRX) was determined in pharmaceutical capsules with differential pulse voltammetry (DPV) in a three electrode system consisting of a pencil graphite electrode (PGE) as working electrode, a Pt wire and a reference electrode of Ag/AgCl/KCl 3 M. An irreversible oxidation peak was observed in Epa c.a. 0.6 V, which correlates to the oxidation of PRX. The coefficient of linear correlation obtained was 0.9946, with limit of detection of 2.1 µM and limit of quantification of 4.7 µM. PGE assays showed good analytical performance compared to high performance liquid chromatography and spectrophotometry, showing the potential to be further developed and employed in quick and simple analyses.

2.
Pharmaceuticals (Basel) ; 12(3)2019 Aug 01.
Article in English | MEDLINE | ID: mdl-31374819

ABSTRACT

This work details the study of the redox behavior of the drugs cyclobenzaprine (CBP), amitriptyline (AMP) and nortriptyline (NOR) through voltammetric methods and computational chemistry. Results obtained in this study show that the amine moiety of each compound is more likely to undergo oxidation at 1a at Ep1a ≈ 0.69, 0.79, 0.93 V (vs. Ag/AgCl/KClsat) for CBP, AMP and NOR, respectively. Moreover, CBP presented a second peak, 2a at Ep2a ≈ 0.98 V (vs. Ag/AgCl/KClsat) at pH 7.0. Furthermore, the electronic structure calculation results corroborate the electrochemical assays regarding the HOMO energies of the lowest energy conformers of each molecule. The mechanism for each anodic process is proposed according to electroanalytical and computational chemistry findings, which show evidence that the methods herein employed may be a valuable alternative to study the redox behavior of structurally similar drugs.

3.
Molecules ; 21(8)2016 Aug 13.
Article in English | MEDLINE | ID: mdl-27529208

ABSTRACT

The development of sensors and biosensors based on copper enzymes and/or copper oxides for phenol sensing is disclosed in this work. The electrochemical properties were studied by cyclic and differential pulse voltammetry using standard solutions of potassium ferrocyanide, phosphate/acetate buffers and representative natural phenols in a wide pH range (3.0 to 9.0). Among the natural phenols herein investigated, the highest sensitivity was observed for rutin, a powerful antioxidant widespread in functional foods and ubiquitous in the plant kingdom. The calibration curve for rutin performed at optimum pH (7.0) was linear in a broad concentration range, 1 to 120 µM (r = 0.99), showing detection limits of 0.4 µM. The optimized biomimetic sensor was also applied in total phenol determination in natural samples, exhibiting higher stability and sensitivity as well as distinct selectivity for antioxidant compounds.


Subject(s)
Biological Products/chemistry , Biomimetics , Biosensing Techniques , Phenols/chemistry , Antioxidants/chemistry , Antioxidants/pharmacology , Biological Products/analysis , Biomimetics/methods , Electrochemical Techniques , Graphite/chemistry , Phenols/analysis
SELECTION OF CITATIONS
SEARCH DETAIL
...