Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Materials (Basel) ; 15(14)2022 Jul 14.
Article in English | MEDLINE | ID: mdl-35888367

ABSTRACT

Fe-based scaffolds are of particular interest in the technology of biodegradable implants due to their high mechanical properties and biocompatibility. In the present work, using an electroexplosive Fe nanopowder and NaCl particles 100-200 µm in size as a porogen, scaffolds with a porosity of about 70 ± 0.8% were obtained. The effect of the sintering temperature on the structure, composition, and mechanical characteristics of the scaffolds was considered. The optimum parameters of the sintering process were determined, allowing us to obtain samples characterized by plastic deformation and a yield strength of up to 16.2 MPa. The degradation of the scaffolds sintered at 1000 and 1100 °C in 0.9 wt.% NaCl solution for 28 days resulted in a decrease in their strength by 23% and 17%, respectively.

2.
Interv Neuroradiol ; 24(4): 357-362, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29720021

ABSTRACT

Background Flow-diverter stents have been successfully used in the treatment of complex aneurysms with limited therapeutic alternatives. We report our experience using the Silk flow diverter (SFD; Balt Extrusion, Montmorency, France) for the treatment of complex aneurysms in four Argentine centers. Methods We conducted a retrospective review of 246 consecutive patients who were treated with the SFD at four Argentine centers between January 2009 and January 2017. The patient and aneurysm characteristics, as well as the details of the procedure, were analyzed. The angiographic and clinical findings were recorded during and immediately after the procedure and at 12-month follow-up. Results Angiography follow-up at 12 months was possible in 235 patients (95.5%) with 282 aneurysms. A total of 265 aneurysms (93.9%) presented with complete occlusion of the aneurysmal sac (class 1) and 17 aneurysms (6.1%) presented with partial occlusion (class 2). The 12-month clinical follow-up showed 11 patients with major events (seven, scale 2; five, scale 3; and two, scale 4). The morbidity and mortality rates were 4.2% (11/289) and 2.1% (5/289), respectively. Conclusions The treatment of aneurysms with the SFD was associated with a low rate of complications and a high percentage of aneurysmal occlusion. These findings suggest that SFD is an effective and safe alternative in the endovascular treatment of complex aneurysms.


Subject(s)
Intracranial Aneurysm/therapy , Stents , Adolescent , Adult , Aged , Argentina , Cerebral Angiography , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prosthesis Design , Retrospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...