Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Language
Publication year range
1.
Biomark Insights ; 18: 11772719231210407, 2023.
Article in English | MEDLINE | ID: mdl-38035182

ABSTRACT

Background: Deregulation in the urokinase-type plasminogen activator receptor (uPA/uPAR) system is reported in many diseases where the immune system is activated. During SARS-CoV-2 infection, a rise in soluble uPAR (suPAR) levels has been detected and its concentration above 6 µg/L predicts worsening to severe respiratory failure 14 days earlier, with a positive predictive value of 85.9%, and was the prerequisite for a treatment with anakinra, a recombinant IL-1 receptor antagonist that blocks the activity of both IL-1α and IL-1ß. Objectives: To compare suPAR concentrations measured by CHORUS suPAR on CHORUS TRIO instrument of DIESSE with the commercially available suPARnostic (ViroGates) ELISA assay. Design: A single-centre, non-pharmacological, diagnostic study was performed. Results: A total of 522 serum samples from patients with COVID-19 were tested for suPAR. CHORUS suPAR resulted accurate and reliable, with a high grade of specificity (97.9%), accuracy (97.3%) and sensitivity (96.9%). The median concentration of suPAR, as determined with CHORUS suPAR, was 6.8 µg/L (interquartile range 4.5-9.7) in patients with moderate disease (n = 465) and 8.5 µg/L (interquartile range 5.4-10.6) in patients with severe disease. Among patients with moderate and severe disease, 60.6% and 71.9%, respectively, reached the cut-off concentration of suPAR ⩾6 µg/L, defining their illness severity and suggesting eligibility to anakinra treatment. Conclusion: CHORUS suPAR kit resulted as sensitive, specific, accurate and able to quantify suPAR concentrations in patients with moderate and severe COVID-19.

2.
Preprint in English | medRxiv | ID: ppmedrxiv-20111682

ABSTRACT

Serological assays for anti-SARS-CoV-2 antibodies are now of critical importance to support diagnosis, guide epidemiological intervention, and understand immune response to natural infection and vaccine administration. We developed and validated new anti-SARS-CoV-2 IgG, IgM and IgA ELISA tests (ENZY-WELL SARS-CoV-2 ELISA, DIESSE Diagnostica Senese S.p.a.) based on whole-virus antigens. We used a total of 553 serum samples including samples from COVID-19 suspected and confirmed cases, healthy donors, and patients positive for other infections or autoimmune conditions. Overall, the assays showed good concordance with the indirect immunofluorescence reference test in terms of sensitivity and specificity. Especially for IgG and IgA, we observed high sensitivity (92.5 and 93.6%, respectively); specificity was high (>96%) for all antibody types ELISAs. In addition, sensitivity was linked to the days from symptoms onset (DSO) due to the seroconversion window, and for ENZY-WELL SARS-CoV-2 IgG and IgA ELISAs resulted 100% in those samples collected after 10 and 12 DSO, respectively. The results showed that ENZY-WELL SARS-CoV-2 ELISAs may represent a valid option for both diagnostic and epidemiological purposes, covering all different antibody types developed in SARS-CoV-2 immune response.

SELECTION OF CITATIONS
SEARCH DETAIL
...