ABSTRACT

On December 5, 2022, an indirect drive fusion implosion on the National Ignition Facility (NIF) achieved a target gain G_{target} of 1.5. This is the first laboratory demonstration of exceeding "scientific breakeven" (or G_{target}>1) where 2.05 MJ of 351 nm laser light produced 3.1 MJ of total fusion yield, a result which significantly exceeds the Lawson criterion for fusion ignition as reported in a previous NIF implosion [H. Abu-Shawareb et al. (Indirect Drive ICF Collaboration), Phys. Rev. Lett. 129, 075001 (2022)PRLTAO0031-900710.1103/PhysRevLett.129.075001]. This achievement is the culmination of more than five decades of research and gives proof that laboratory fusion, based on fundamental physics principles, is possible. This Letter reports on the target, laser, design, and experimental advancements that led to this result.

2.
Phys Rev Lett ; 129(7): 075001, 2022 Aug 12.
Article in English | MEDLINE | ID: mdl-36018710

ABSTRACT

For more than half a century, researchers around the world have been engaged in attempts to achieve fusion ignition as a proof of principle of various fusion concepts. Following the Lawson criterion, an ignited plasma is one where the fusion heating power is high enough to overcome all the physical processes that cool the fusion plasma, creating a positive thermodynamic feedback loop with rapidly increasing temperature. In inertially confined fusion, ignition is a state where the fusion plasma can begin "burn propagation" into surrounding cold fuel, enabling the possibility of high energy gain. While "scientific breakeven" (i.e., unity target gain) has not yet been achieved (here target gain is 0.72, 1.37 MJ of fusion for 1.92 MJ of laser energy), this Letter reports the first controlled fusion experiment, using laser indirect drive, on the National Ignition Facility to produce capsule gain (here 5.8) and reach ignition by nine different formulations of the Lawson criterion.

3.
Rev Sci Instrum ; 92(5): 053003, 2021 May 01.
Article in English | MEDLINE | ID: mdl-34243266

ABSTRACT

We simulate the use of a newly developed single-shot wavelength-multiplexed holography-based diagnostic, STRIPED FISH, to fully characterize the as-delivered laser pulses of the National Ignition Facility's Advanced Radiographic Capability (NIF-ARC) laser. To that end, we have performed simulations of the NIF-ARC pulse incorporating (a) a time-integrated spatial-profile measurement and a complete temporal-intensity-and-phase measurement using a frequency resolved optical gating, but without any spatiotemporal pulse characterizations, and (b) simulated first-order spatiotemporal distortions, which could be measured on a single shot if a STRIPED FISH device were deployed.

4.
Rev Sci Instrum ; 92(4): 043712, 2021 Apr 01.
Article in English | MEDLINE | ID: mdl-34243490

ABSTRACT

To study matter at extreme densities and pressures, we need mega laser facilities such as the National Ignition Facility as well as creative methods to make observations during timescales of a billionth of a second. To facilitate this, we developed a platform and diagnostic to characterize a new point-projection radiography configuration using two micro-wires irradiated by a short pulse laser system that provides a large field of view with up to 3.6 ns separation between images. We used tungsten-carbide solid spheres as reference objects and inferred characteristics of the back-lighter source using a forward-fitting algorithm. The resolution of the system is inferred to be 15 µm (using 12.5 µm diameter wires). The bremsstrahlung temperature of the source is 70-300 keV, depending on laser energy and coupling efficiency. By adding the images recorded on multiple stacked image plates, the signal-to-noise of the system is nearly doubled. The imaging characterization technique described here can be adapted to most point-projection platforms where the resolution, spectral contrast, and signal-to-noise are important.

5.
Phys Rev E ; 103(3): L031201, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33862680

ABSTRACT

Achieving a high conversion efficiency into relativistic electrons is central to short-pulse laser application and fundamentally relies on creating interaction regions with intensities ≫10^{18}W/cm^{2}. Small focal length optics are typically employed to achieve this goal; however, this solution is impractical for large kJ-class systems that are constrained by facility geometry, debris concerns, and component costs. We fielded target-mounted compound parabolic concentrators to overcome these limitations and achieved nearly an order-of-magnitude increase to the conversion efficiency and more than tripled electron temperature compared to flat targets. Particle-in-cell simulations demonstrate that plasma confinement within the cone and formation of turbulent laser fields that develop from cone wall reflections are responsible for the improved laser-to-target coupling. These passive target components can be used to improve the coupling efficiency for all high-intensity short-pulse laser applications, particularly at large facilities with long focal length optics.

6.
Phys Rev Lett ; 125(15): 155003, 2020 Oct 09.
Article in English | MEDLINE | ID: mdl-33095614

ABSTRACT

The implosion efficiency in inertial confinement fusion depends on the degree of stagnated fuel compression, density uniformity, sphericity, and minimum residual kinetic energy achieved. Compton scattering-mediated 50-200 keV x-ray radiographs of indirect-drive cryogenic implosions at the National Ignition Facility capture the dynamic evolution of the fuel as it goes through peak compression, revealing low-mode 3D nonuniformities and thicker fuel with lower peak density than simulated. By differencing two radiographs taken at different times during the same implosion, we also measure the residual kinetic energy not transferred to the hot spot and quantify its impact on the implosion performance.

7.
Phys Rev E ; 101(3-1): 031201, 2020 Mar.
Article in English | MEDLINE | ID: mdl-32289929

ABSTRACT

Relativistic electron temperatures were measured from kilojoule, subrelativistic laser-plasma interactions. Experiments show an order of magnitude higher temperatures than expected from a ponderomotive scaling, where temperatures of up to 2.2 MeV were generated using an intensity of 1×10^{18}W/cm^{2}. Two-dimensional particle-in-cell simulations suggest that electrons gain superponderomotive energies by stochastic acceleration as they sample a large area of rapidly changing laser phase. We demonstrate that such high temperatures are possible from subrelativistic intensities by using lasers with long pulse durations and large spatial scales.

8.
Aquat Toxicol ; 211: 1-10, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30901626

ABSTRACT

Flowback and produced water (FPW) is a complex, often brackish, solution formed during the process of hydraulic fracturing. Despite recent findings on the short-term toxicity of FPW on aquatic biota, longer-term impacts of FPW on fish have not yet been investigated and the mechanisms of chronic effects remain unknown. The aim of the present study was to observe the effect of a diluted FPW on ionoregulatory endpoints in the rainbow trout Oncorhynchus mykiss, following a 28-d sub-chronic exposure. A salinity-matched control solution (SW), recreating the salt content of the FPW, was used to differentiate the specific effect of the salts from the effects of the other FPW components (i.e. organics and metals). Overall, fish ionoregulation was not impacted by the chronic exposure. An accumulation of strontium (Sr) and bromide (Br) occurred in the plasma of the FPW-exposed fish only, however no change of plasma ions (Na, K, Cl, Ca, Mg) was observed in SW- or FPW-exposed fish. Similarly, exposures did not alter branchial activity of the osmoregulatory enzymes sodium/potassium ATPase and proton ATPase. Finally, FPW exposure resulted in modifications of gill morphology over time, with fish exposed to the fluid displaying shorter lamellae and increased interlamellar-cell mass. However, these effects were not distinct from morphological changes that also occurred in the gills of control groups.


Subject(s)
Environmental Monitoring/methods , Gills/drug effects , Hydraulic Fracking , Oncorhynchus mykiss/metabolism , Water Pollutants, Chemical/toxicity , Animals , Chlorides/blood , Gills/enzymology , Gills/pathology , Models, Theoretical , Oncorhynchus mykiss/blood , Osmosis , Sodium/blood , Sodium-Potassium-Exchanging ATPase/metabolism , Toxicity Tests, Acute , Toxicity Tests, Subchronic
9.
Environ Sci Process Impacts ; 21(2): 224-241, 2019 Feb 21.
Article in English | MEDLINE | ID: mdl-30452047

ABSTRACT

Accurate and precise analyses of oil and gas (O&G) wastewaters and solids (e.g., sediments and sludge) are important for the regulatory monitoring of O&G development and tracing potential O&G contamination in the environment. In this study, 15 laboratories participated in an inter-laboratory comparison on the chemical characterization of three O&G wastewaters from the Appalachian Basin and four solids impacted by O&G development, with the goal of evaluating the quality of data and the accuracy of measurements for various analytes of concern. Using a variety of different methods, analytes in the wastewaters with high concentrations (i.e., >5 mg L-1) were easily detectable with relatively high accuracy, often within ±10% of the most probable value (MPV). In contrast, often less than 7 of the 15 labs were able to report detectable trace metal(loid) concentrations (i.e., Cr, Ni, Cu, Zn, As, and Pb) with accuracies of approximately ±40%. Despite most labs using inductively coupled plasma mass spectrometry (ICP-MS) with low instrument detection capabilities for trace metal analyses, large dilution factors during sample preparation and low trace metal concentrations in the wastewaters limited the number of quantifiable determinations and likely influenced analytical accuracy. In contrast, all the labs measuring Ra in the wastewaters were able to report detectable concentrations using a variety of methods including gamma spectroscopy and wet chemical approaches following Environmental Protection Agency (EPA) standard methods. However, the reported radium activities were often greater than ±30% different to the MPV possibly due to calibration inconsistencies among labs, radon leakage, or failing to correct for self-attenuation. Reported radium activities in solid materials had less variability (±20% from MPV) but accuracy could likely be improved by using certified radium standards and accounting for self-attenuation that results from matrix interferences or a density difference between the calibration standard and the unknown sample. This inter-laboratory comparison illustrates that numerous methods can be used to measure major cation, minor cation, and anion concentrations in O&G wastewaters with relatively high accuracy while trace metal(loid) and radioactivity analyses in liquids may often be over ±20% different from the MPV.


Subject(s)
Inorganic Chemicals/analysis , Laboratories/organization & administration , Petroleum/analysis , Radioactive Pollutants/analysis , Wastewater/chemistry , Appalachian Region
10.
Opt Express ; 25(13): 15161-15178, 2017 Jun 26.
Article in English | MEDLINE | ID: mdl-28788946

ABSTRACT

Laser-induced damage with ps pulse widths straddles the transition from intrinsic, multi-photon ionization and avalanche ionization-based ablation with fs pulses to defect-dominated, thermal-based damage with ns pulses. We investigated the morphology of damage for fused silica and silica coatings between 1 ps and 60 ps at 1053 nm. Using calibrated laser-induced damage experiments, in situ imaging, and high-resolution optical microscopy, atomic force microscopy, and scanning electron microscopy, we show that defects play an important role in laser-induced damage down to 1 ps. Three types of damage are observed: ablation craters, ultra-high density pits, and smooth, circular depressions with central pits. For 10 ps and longer, the smooth, circular depressions limit the damage performance of fused silica and silica coatings. The observed high-density pits and material removal down to 3 ps indicate that variations in surface properties limit the laser-induced damage onset to a greater extent than expected below 60 ps. Below 3 ps, damage craters are smoother although there is still evidence as seen by AFM of inhomogeneous laser-induced damage response very near the damage onset. These results show that modeling the damage onset only as a function of pulse width does not capture the convoluted processes leading to laser induced damage with ps pulses. It is necessary to account for the effects of defects on the processes leading to laser-induced damage. The effects of isolated defects or inhomogeneities are most pronounced above 3 ps but are still discernible and possibly important down to the shortest pulse width investigated here.

11.
Opt Express ; 25(13): 15381-15401, 2017 Jun 26.
Article in English | MEDLINE | ID: mdl-28788965

ABSTRACT

We investigate the role of defects in laser-induced damage of fused silica and of silica coatings produced by e-beam and PIAD processes which are used in damage resistant, multi-layer dielectric, reflective optics. We perform experiments using 1053 nm, 1-60 ps laser pulses with varying beam size, number of shots, and pulse widths in order to understand the characteristics of defects leading to laser-induced damage. This pulse width range spans a transition in mechanisms from intrinsic material ablation for short pulses to defect-dominated damage for longer pulses. We show that for pulse widths as short as 10 ps, laser-induced damage properties of fused silica and silica films are dominated by isolated absorbers. The density of these precursors and their fluence dependence of damage initiation suggest a single photon process for initial energy absorption in these precursors. Higher density precursors that initiate close to the ablation threshold at shorter pulse widths are also observed in fused silica, whose fluence and pulse width scaling suggest a multiphoton initiation process. We also show that these initiated damage sites grow with subsequent laser pulses. We show that scaling laws obtained in more conventional ways depend on the beam size and on the definition of damage for ps pulses. For this reason, coupling scaling laws with the density of precursors are critical to understanding the damage limitations of optics in the ps regime.

12.
Phys Rev Lett ; 111(23): 235004, 2013 Dec 06.
Article in English | MEDLINE | ID: mdl-24476282

ABSTRACT

We present the first measurements of the angular dependence of the betatron x-ray spectrum produced by electrons inside the cavity of a laser-wakefield accelerator. Electrons accelerated up to 300 MeV energies produce a beam of broadband, forward-directed betatron x-ray radiation extending up to 80 keV. The angular resolved spectrum from an image plate-based spectrometer with differential filtering provides data in a single laser shot. The simultaneous spectral and spatial x-ray analysis allows for a three-dimensional reconstruction of electron trajectories with micrometer resolution, and we find that the angular dependence of the x-ray spectrum is showing strong evidence of anisotropic electron trajectories.

13.
Cell Death Dis ; 3: e323, 2012 Jun 21.
Article in English | MEDLINE | ID: mdl-22717578

ABSTRACT

Toll-like receptor 9 (TLR9) triggering is a promising novel strategy to combat cancer as it induces innate and adaptive immunity responses. B-cell lymphoma is unique in this context as tumor cells express TLR9 and may harbor latent Epstein-Barr virus (EBV), a gamma-herpesvirus with remarkable oncogenic potential when latent. Latent EBV may be promoted by TLR9 triggering via suppression of lytic EBV. Here, we elaborated an initial assessment of the impact of TLR9 triggering on EBV-positive and EBV-negative B-cell lymphoma using Burkitt's lymphoma (BL) cell lines as an in vitro model. We show that, independent of the presence of EBV, the TLR9 ligand oligodeoxynucleotide (ODN) CpG-2006 may or may not induce caspase-dependent cell death in BL cells. Moreover, ODN CpG-2006-induced cell death responses of BL cells were associated with TLR9 single-nucleotide polymorphisms (SNPs) rs5743836 or rs352140, which we detected in primary BL tumors and in peripheral blood from healthy individuals at similar frequencies. Thus, our findings suggest that the effect of TLR9 agonists on BL cells should be tested in vitro before installment of therapy and TLR9 SNPs in BL patients should be determined as potential biological markers for the therapeutic response to treatment targeting innate immunity.


Subject(s)
Burkitt Lymphoma/metabolism , Oligodeoxyribonucleotides/pharmacology , Polymorphism, Genetic , Toll-Like Receptor 9/agonists , Toll-Like Receptor 9/genetics , Adult , Aged , Burkitt Lymphoma/pathology , Burkitt Lymphoma/virology , Cell Death/drug effects , CpG Islands , Herpesvirus 4, Human/physiology , Humans , Membrane Glycoproteins/genetics , Membrane Glycoproteins/metabolism , Middle Aged , Receptors, Interleukin-1/genetics , Receptors, Interleukin-1/metabolism
14.
Minerva Pediatr ; 64(4): 395-400, 2012 Aug.
Article in Italian | MEDLINE | ID: mdl-22728611

ABSTRACT

AIM: The Cri du Chat syndrome (SCdC / [OMIM #123450]) is a rare disease characterized by the deletion of the short arm of chromosome 5. The typical clinical features are the cat-like cry, microcephaly, a distinct facial phenotype and a severe psychomotor and mental retardation. The aim of this study was to provide an analysis on the data concerning the life quality and families assistance to whom have a child affected by Cri du Chat syndrome such as: the life's change of parents after the child's birth, the frequency of treatments, the collaboration between family and center of reference. METHODS: We have also analyzed the improvement obtained, the type of school attended, the aide and the time spent at home in postprimary education. Through a questionnaire sent to 100 families, we have been picked up information on 76 patients. RESULTS: These families have to adapt to the reality of a child with a rare genetic disorder for which there are no pharmacological or surgical therapies. CONCLUSION: Therefore, it seems important to give information and tips for dealing with the disease and the early start of rehabilitation and educational therapy.


Subject(s)
Cri-du-Chat Syndrome/genetics , Cri-du-Chat Syndrome/rehabilitation , Quality of Health Care , Quality of Life , Adolescent , Cri-du-Chat Syndrome/diagnosis , Cri-du-Chat Syndrome/epidemiology , Humans , Infant , Intellectual Disability/genetics , Italy/epidemiology , Microcephaly/genetics , Surveys and Questionnaires , Young Adult
15.
Br J Cancer ; 106(6): 1117-22, 2012 Mar 13.
Article in English | MEDLINE | ID: mdl-22361631

ABSTRACT

BACKGROUND: Observations that diabetics treated with biguanide drugs have a reduced risk of developing cancer have prompted an enthusiasm for these agents as anti-cancer therapies. We sought to determine the efficacy of the biguanide phenformin in the chemoprophylaxis and in the treatment of oestrogen receptor (ER)-positive MCF7 and receptor triple-negative MDAMB231 xenografts in immunocompromised mice. We also compared the efficacy of phenformin and metformin in the treatment of MDAMB231. METHODS: Immunocompromised mice were divided into groups: (1) phenformin administered for 2 weeks prior to cell injection; (2) established tumours treated with phenformin; (3) established tumours treated with metformin (only for MDAMB231 tumours); (4) untreated controls. Post-treatment tumours, liver and spleen were harvested for further analysis. RESULTS: Phenformin significantly inhibited both the development and growth of MCF7 and MDAMB231 tumours, and for MDAMB231 at greater efficacy than metformin without murine toxicity. The number of mitotic figures was significantly fewer in xenografts treated with phenformin compared with controls. Results suggested that the mechanism of action of phenformin in vivo is consistent with AMPK activation. CONCLUSION: Phenformin has clinical potential as an antineoplastic agent and should be considered for clinical trials both in ER-positive and triple-negative breast cancer.


Subject(s)
Anticarcinogenic Agents/therapeutic use , Antineoplastic Agents/therapeutic use , Breast Neoplasms/prevention & control , Metformin/therapeutic use , Phenformin/therapeutic use , Adenylate Kinase/metabolism , Animals , Anticarcinogenic Agents/pharmacology , Antineoplastic Agents/pharmacology , Breast Neoplasms/drug therapy , Breast Neoplasms/metabolism , Breast Neoplasms/pathology , Cell Line, Tumor , Enzyme Activation , Female , Histones/metabolism , Humans , Ki-67 Antigen/metabolism , Liver/enzymology , Metformin/pharmacology , Mice , Mice, Nude , Phenformin/pharmacology , Poly (ADP-Ribose) Polymerase-1 , Poly(ADP-ribose) Polymerases/metabolism , Spleen/enzymology , Tumor Burden/drug effects , Xenograft Model Antitumor Assays
16.
Opt Express ; 19(13): 12087-92, 2011 Jun 20.
Article in English | MEDLINE | ID: mdl-21716445

ABSTRACT

The temporal coherence of an injection-seeded transient 18.9 nm molybdenum soft x-ray laser was measured using a wavefront division interferometer and compared to model simulations. The seeded laser is found to have a coherence time similar to that of the unseeded amplifier, ~1 ps, but a significantly larger degree of temporal coherence. The measured coherence time for the unseeded amplifier is only a small fraction of the pulsewidth, while in the case of the seeded laser it approaches full temporal coherence. The measurements confirm that the bandwidth of the solid target amplifiers is significantly wider than that of soft x-ray lasers that use gaseous targets, an advantage for the development of sub-picosecond soft x-ray lasers.


Subject(s)
Gases/chemistry , Interferometry/instrumentation , Lasers , Molybdenum/chemistry , Amplifiers, Electronic , Computer Simulation , Equipment Design , Fourier Analysis , Models, Theoretical , Ultraviolet Rays , X-Rays
17.
Br J Cancer ; 104(7): 1116-25, 2011 Mar 29.
Article in English | MEDLINE | ID: mdl-21407213

ABSTRACT

BACKGROUND: The PI3K-mTOR (phosphoinositide 3-kinase-mammalian target of rapamycin kinase) pathway is activated in the majority of tumours, and there is interest in assessing whether inhibitors of PI3K or mTOR kinase have efficacy in treating cancer. Here, we define the effectiveness of specific mTOR (AZD8055) and PI3K (GDC-0941) inhibitors, currently in clinical trials, in treating spontaneous B-cell follicular lymphoma that develops in PTEN(+/-)LKB1(+/hypo) mice. METHODS: The PTEN(+/-)LKB1(+/hypo) mice were administered AZD8055 or GDC-0941, and the volumes of B-cell follicular lymphoma were measured by MRI. Tumour samples were analysed by immunohistochemistry, immunoblot and flow cytometry. RESULTS: The AZD8055 or GDC-0941 induced ∼40% reduction in tumour volume within 2 weeks, accompanied by ablation of phosphorylation of AKT, S6K and SGK (serum and glucocorticoid protein kinase) protein kinases. The drugs reduced tumour cell proliferation, promoted apoptosis and suppressed centroblast population. The AZD8055 or GDC-0941 treatment beyond 3 weeks caused a moderate additional decrease in tumour volume, reaching ∼50% of the initial volume after 6 weeks of treatment. Tumours grew back at an increased rate and displayed similar high grade and diffuse morphology as the control untreated tumours upon cessation of drug treatment. CONCLUSION: These results define the effects that newly designed and specific mTOR and PI3K inhibitors have on a spontaneous tumour model, which may be more representative than xenograft models frequently employed to assess effectiveness of kinase inhibitors. Our data suggest that mTOR and PI3K inhibitors would benefit treatment of cancers in which the PI3K pathway is inappropriately activated; however, when administered alone, may not cause complete regression of such tumours.


Subject(s)
Lymphoma, B-Cell/drug therapy , Lymphoma, Follicular/drug therapy , PTEN Phosphohydrolase/physiology , Phosphoinositide-3 Kinase Inhibitors , Protein Kinase Inhibitors/therapeutic use , Protein Serine-Threonine Kinases/physiology , TOR Serine-Threonine Kinases/antagonists & inhibitors , AMP-Activated Protein Kinases , Animals , Indazoles/therapeutic use , Lymphoma, B-Cell/pathology , Lymphoma, Follicular/pathology , Mice , Mice, Inbred C57BL , Morpholines/therapeutic use , Phosphatidylinositol 3-Kinases/physiology , Signal Transduction , Sulfonamides/therapeutic use , TOR Serine-Threonine Kinases/physiology
18.
Opt Lett ; 35(10): 1632-4, 2010 May 15.
Article in English | MEDLINE | ID: mdl-20479832

ABSTRACT

We have demonstrated repetitive operation of a table-top lambda=13.9 nm Ni-like Ag soft-x-ray laser that generates laser pulses with 10 microJ energy. The soft-x-ray laser is enabled by a Ti:sapphire laser pumped by high-repetition-rate frequency-doubled high-energy Nd:glass slab amplifiers. Soft-x-ray laser operation at 2.5 Hz repetition rate resulted in 20 microwatt average power.

19.
Opt Lett ; 35(3): 414-6, 2010 Feb 01.
Article in English | MEDLINE | ID: mdl-20125739

ABSTRACT

We report the demonstration of a gain-saturated 10.9 nm tabletop soft x-ray laser operating at 1 Hz repetition rate. Lasing occurs by collisional electron impact excitation in the 4dS01-->4pP11 transition of nickel-like Te in a line-focus plasma heated by a chirped-pulse-amplification Ti:sapphire laser. With an average power of 1muW and pulse energy up to approximately 2microJ, this laser extends the ability to conduct tabletop laser experiments to a shorter wavelength.

20.
Opt Express ; 17(26): 23809-16, 2009 Dec 21.
Article in English | MEDLINE | ID: mdl-20052091

ABSTRACT

We have demonstrated broad bandwidth large area (229 mm x 114 mm) multilayer dielectric diffraction gratings for the efficient compression of high energy 800 nm laser pulses at high average power. The gratings are etched in the top layers of an aperiodic (Nb0.5Ta0.5)2O5-SiO2 multilayer coating deposited by ion beam sputtering. The mean efficiency of the grating across the area is better than 97% at the center wavelength and remains above 96% at wavelengths between 820 nm and 780 nm. The gratings were used to compress 5.5 J pulses from a Ti:sapphire laser with an efficiency above 80 percent.


Subject(s)
Lasers , Lighting/instrumentation , Refractometry/instrumentation , Computer-Aided Design , Equipment Design , Equipment Failure Analysis