Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMJ Open ; 8(11): e025533, 2018 11 15.
Article in English | MEDLINE | ID: mdl-30446576

ABSTRACT

OBJECTIVES: To further validate the diagnostic utility of 18F-AV-133 vesicular monoamine transporter type 2 (VMAT2) positron emission tomography (PET) in patients with clinically uncertain parkinsonian syndromes (CUPS) by comparison to clinical diagnosis at 3 years follow-up. DESIGN, SETTING AND PARTICIPANTS: In a previous study, we reported that 18F-AV-133 PET in community patients with CUPS changed diagnosis and management and increased diagnostic confidence. The current diagnosis of this cohort was obtained from the patient and treating specialist and compared with the diagnosis suggested 3 years earlier by the 18F-AV-133 PET. A second 18F-AV-133 PET was available in those with a discordant or inconclusive final diagnosis. STUDY OUTCOME MEASURES: The primary end point was the proportion of patients who had a follow-up clinical diagnosis, which was concordant with their initial 18F-AV-133 PET scan. Secondary end points were the proportion of patients who had the same diagnosis at follow-up as that reached after the initial scan and the stability of diagnostic changes made after the first scan. RESULTS: 81 of the 85 patients previously recruited to the CUPS study had follow-up of which 79 had a clinical diagnosis and 2 remained CUPS. The diagnosis was in agreement with the initial 18F-AV-133 PET scan result in 74 cases. Five patients had a discordant diagnosis; one patient with rubral tremor had a severely abnormal scan that had worsened when rescanned; four cases with normal initial and repeat scans had a clinical diagnosis of Parkinson's disease. Two patients with suspected genetic disorders remained classified as CUPS and both had normal scans. In the 24 CUPS cohort patients where 18F-AV-133 PET initially changed diagnosis, this change was supported by follow-up diagnosis in all but the one rubral tremor case. CONCLUSION: 18F-AV-133 PET is a useful tool in improving diagnostic accuracy in CUPS providing results and diagnostic changes that remain robust after 3 years follow-up.


Subject(s)
Brain/diagnostic imaging , Parkinsonian Disorders/diagnostic imaging , Positron-Emission Tomography , Uncertainty , Vesicular Monoamine Transport Proteins/analysis , Aged , Caudate Nucleus/diagnostic imaging , Cohort Studies , Diagnosis, Differential , Disease Progression , Female , Follow-Up Studies , Humans , Male , Middle Aged , Putamen/diagnostic imaging , Reference Values , Sensitivity and Specificity
2.
J Nucl Med ; 58(11): 1815-1820, 2017 11.
Article in English | MEDLINE | ID: mdl-28490469

ABSTRACT

Idiopathic Parkinson disease is a common neurodegenerative disorder for which misdiagnosis occurs in up to 30% of patients after initial assessment and in 10%-15% even after long-term follow-up. Vesicular monoamine transporter type 2 (VMAT2) imaging with PET allows assessment of the integrity of the presynaptic dopaminergic pathway. We investigated the management impact of VMAT2 imaging in patients with clinically uncertain Parkinsonian syndromes. Methods: Forty-seven patients with clinically uncertain Parkinsonian syndromes (mean age ± SD, 56.9 ± 14.9 y; age range, 21-80 y) were referred from movement disorder specialists. All participants underwent a 20-min PET acquisition 2 h after injection of 250 MBq of 18F-AV-133, and the resulting images were quantitatively assessed. Clinical impact was recorded as high, moderate, or low based on diagnosis and management questionnaires completed by the referring specialists before and after release of the PET results. Management impact was high if there was a change in diagnostic category, moderate if there was a change in medication, and low if there was no change. Results: VMAT2 PET changed the diagnosis in 11 (23%) and medication in 25 (53%) participants. Management impact was high in 23%, moderate in 38%, and low in 39% of the participants. High diagnostic confidence increased from 11% of patients to 80% after the release of the scan results. Conclusion:18F-AV-133 had substantial management impact in patients with clinically uncertain Parkinsonian syndromes. VMAT2 imaging with 18F-AV133 might improve diagnosis, prognosis, and appropriate use of medication, translating into better patient outcomes.


Subject(s)
Brain/diagnostic imaging , Parkinsonian Disorders/diagnostic imaging , Parkinsonian Disorders/metabolism , Positron-Emission Tomography/methods , Radiopharmaceuticals , Tetrabenazine/analogs & derivatives , Vesicular Monoamine Transport Proteins/metabolism , Adult , Aged , Aged, 80 and over , Antiparkinson Agents/administration & dosage , Antiparkinson Agents/therapeutic use , Brain Chemistry , Case Management , Female , Fluorine Radioisotopes , Humans , Image Processing, Computer-Assisted , Male , Middle Aged , Molecular Imaging , Neuroimaging , Parkinsonian Disorders/drug therapy , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...