1.
J Clin Med ; 13(8)2024 Apr 11.
Article in English | MEDLINE | ID: mdl-38673477

ABSTRACT

The number of endovascular aortic repairs (EVARs) has surpassed the number of open surgical repairs of abdominal aortic aneurysms (AAAs) worldwide. The available commercial endoprostheses are composed of materials that are stiffer than the native aortic wall. As a consequence, the implantation of stent-graft endoprostheses during EVAR increases aortic rigidity and thus aortic stiffness, resulting in a decrease in abdominal aorta compliance. EVAR has been found to have a possibly harmful effect not only on heart functions but also on other vascular beds, including kidney function, due to the decrease in aortic compliance that it causes. Aortic stiffness is measured by various hemodynamic indices like the pulse wave velocity (PWV), the central aortic pressure (CAP), and the augmentation index (AIx). In the literature, there are increasing numbers of studies investigating the properties of endografts, which are strongly related to increases in aortic stiffness. However, there is a lack of data on whether there is a correlation between the length of various endografts implanted during EVAR and the increase in the PWV, CAP, and AIx postoperatively compared to the preoperative values. The aim of this prospective, observational, monocentric, single-arm study is to investigate the correlation between endograft length and the postoperative increase in the PWV, CAP, and AIx in patients subjected to EVAR. Additionally, this study intends to identify other endograft properties related to increases in the PWV, CAP, and AIx. Other endpoints to be studied are the existence of immediate postoperative myocardial and kidney injury after EVAR. The prediction of cardiovascular events caused by endograft-related increased aortic stiffness could contribute to the improvement of various endograft properties so that the impact of endografts on the native aortic wall can be minimized.

2.
Ann Vasc Surg ; 104: 93-109, 2023 Jul 17.
Article in English | MEDLINE | ID: mdl-37468059

ABSTRACT

BACKGOUND: The number of endovascular abdominal aortic aneurysm repairs (EVARs) has surpassed the number of open surgical repair of AAAs worldwide with a great variety of endografts being available. The aim of this study is to conduct a systematic review of the literature and meta-analysis of studies reporting patients with infrarenal abdominal aortic aneurysm (AAA) subjected to EVAR with the Anaconda endograft. METHODS: We performed a systematic review of multiple electronic databases for studies including patients with infrarenal AAA who were subjected to elective EVAR with Anaconda endograft exclusively. We conducted a proportional meta-analysis cumulating the results of the included studies. The endpoints were first month overall mortality, first and second-year survival after EVAR, AAA-related deaths, incidence of endoleaks, endograft migration, endograft occlusion, open conversion, and primary and secondary technical success. The mean value for each separate studied factor was calculated, and the respective percentage or incidence was extracted so that it can be compared to endograft outcome studies in the literature. We assessed the methodologic quality of studies by using the Briggs Institute critical appraisal tool. RESULTS: Seven observational studies were found including 954 patients (males 91.9%, mean age 73.38 ± 6.97 years). The mean transverse diameter of AAAs was 56.83 ± 9.97 mm. The mean proximal aortic neck diameter and length were 23.06 ± 3.33 mm and 24.14 ± 12.16 mm, respectively. Increased aortic neck calcification and aortic neck thrombus were present in 12.5% of patients. The 30-day overall mortality post-EVAR was 1.3%, 1 and 2-year survival rates were 95.9% and 91.4%, respectively. The mean follow-up period in the studies was 46.59 ± 15.5 months. AAA-related mortality was 1.3%. Primary technical success was 97.9% and secondary success was 99.3%. Open conversion was required in 3.4% of all patients (0.6% during the primary operation [Prim. Op]). The most common endoleak was type II, reported in 17.4% of all patients. Early type Ia endoleak was reported in 1.5% of patients and late type Ia in 1.7%. Overall, 2 endoleaks type III and 1 type IV were reported. Endograft migration occurred in 1.7% of patients. Main body and/or one/both iliac legs thrombotic occlusion was found totally in 7.6% of patients (5 main body occlusions and 64 iliac leg occlusions). CONCLUSIONS: The use of Anaconda endograft in electively treated patients with infrarenal AAAs presented good results with high technical success and low postoperative and mid-term complications, except for an increased incidence of stent-graft thrombosis, which seems to be the "Achilles heel" of the device.

SELECTION OF CITATIONS
SEARCH DETAIL
...