Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
Add more filters










Database
Language
Publication year range
1.
Sens Actuators A Phys ; 3262021 Aug 01.
Article in English | MEDLINE | ID: mdl-35386682

ABSTRACT

This report presents a review of progress on peristaltic micropumps since their emergence, which have been widely used in many research fields from biology to aeronautics. This paper summarizes different techniques that have been used to mimic this elegant physiological transport mechanism that is commonly found in nature. The analysis provides definitions of peristaltic micropumps and their different features, distinguishing them from other mechanical micropumps. Important parameters in peristalsis are presented, such as the operating frequency, stroke volume, and various actuation sequences, along with introducing design rules and analysis for optimizing actuation sequences. Actuation methods such as piezoelectric, motor, pneumatic, electrostatic, and thermal are discussed with their advantages and disadvantages for application in peristaltic micropumps. This review evaluates research efforts over the past 30 years with comparison of key features and outputs, and suggestions for future development. The analysis provides a starting point for researchers designing peristaltic micropumps for a broad range of applications.

2.
Materials (Basel) ; 12(6)2019 Mar 20.
Article in English | MEDLINE | ID: mdl-30897771

ABSTRACT

This paper demonstrates an easily prepared novel material and approach to producing aligned nickel (Ni) nanowires having unique and customizable structures on a variety of substrates for electronic and magnetic applications. This is a new approach to producing printed metallic Ni structures from precursor materials, and it provides a novel technique for nanowire formation during reduction. This homogeneous solution can be printed in ambient conditions, and it forms aligned elemental Ni nanowires over large areas upon heating in the presence of a magnetic field. The use of templates or subsequent purification are not required. This technique is very flexible, and allows the preparation of unique patterns of nanowires which provides opportunities to produce structures with enhanced anisotropic electrical and magnetic properties. An example of this is the unique fabrication of aligned nanowire grids by overlaying layers of nanowires oriented at different angles with respect to each other. The resistivity of printed and cured films was found to be as low as 560 µΩ∙cm. The saturation magnetization was measured to be 30 emu∙g-1, which is comparable to bulk Ni. Magnetic anisotropy was induced with an axis along the direction of the applied magnetic field, giving soft magnetic properties.

3.
J Control Release ; 298: 27-37, 2019 03 28.
Article in English | MEDLINE | ID: mdl-30690105

ABSTRACT

Advances in protective and restorative biotherapies have created new opportunities to use site-directed, programmable drug delivery systems to treat auditory and vestibular disorders. Successful therapy development that leverages the transgenic, knock-in, and knock-out variants of mouse models of human disease requires advanced microsystems specifically designed to function with nanoliter precision and with system volumes suitable for implantation. Here we present results for a novel biocompatible, implantable, scalable, and wirelessly controlled peristaltic micropump. The micropump configuration included commercially available catheter microtubing (250 µm OD, 125 µm ID) that provided a biocompatible leak-free flow path while avoiding complicated microfluidic interconnects. Peristaltic pumping was achieved by sequentially compressing the microtubing via expansion and contraction of a thermal phase-change material located in three chambers integrated adjacent to the microtubing. Direct-write micro-scale printing technology was used to build the mechanical components of the micropump around the microtubing directly on the back of a printed circuit board assembly (PCBA). The custom PCBA was fabricated using standard commercial processes providing microprocessor control of actuation and Bluetooth wireless communication through an Android application. The results of in vitro characterization indicated that nanoliter resolution control over the desired flow rates of 10-100 nL/min was obtained by changing the actuation frequency. Applying 10× greater than physiological backpressures and ±â€¯3 °C ambient temperature variation did not significantly affect flow rates. Three different micropumps were tested on six mice for in vivo implantation of the catheter microtubing into the round window membrane niche for infusion of a known ototoxic compound (sodium salicylate) at 50 nL/min for 20 min. Real-time shifts in distortion product otoacoustic emission thresholds and amplitudes were measured during the infusion. There were systematic increases in distortion product threshold shifts during the 20-min perfusions; the mean shift was 15 dB for the most basal region. A biocompatibility study was performed to evaluate material suitability for chronic subcutaneous implantation and clinical translational development. The results indicated that the micropump components successfully passed key biocompatibility tests. A micropump prototype was implanted for one month without development of inflammation or infection. Although tested here on the small murine cochlea, this low-cost design and fabrication methodology is scalable for use in larger animals and for clinical applications in children and adults by appropriate scaling of the microtubing diameter and actuator volume.


Subject(s)
Drug Delivery Systems , Ear, Inner/metabolism , Infusion Pumps, Implantable , Sodium Salicylate/administration & dosage , Animals , Equipment Design , Mice , Mice, Inbred CBA , Microfluidics
4.
Mater Des ; 150: 86-93, 2018 Jul 15.
Article in English | MEDLINE | ID: mdl-30364560

ABSTRACT

A one-of-a-kind biocompatible magnetic nanocomposite microcapsule is developed as an in-line passive valve that can be integrated with micropumps and microfluidics. The magnetic nanocomposites act as the core for building a valve that utilizes the magnetic force attraction for sealing the microfluidic channels. The nanocomposites, molded with commercial microtubings, are prepared by incorporating Fe3O4 nanoparticles into polyethylene-glycol (PEG). Parylene-C provides a flexible, biocompatible shell and moisture barrier for the microcapsule that enables deformation and sealing to the microfluidic channel wall. The highly customizable valve design offers easy scalability, and simplicity for integration into microfluidic systems. The presented magnetically-responsive microcapsule demonstrates reliable performance as a passive one-way valve that exhibits unique features and capabilities including effective flow-rectification with steady flows, extremely low leakage flows from backpressures at a rate of 4.7 nL/min kPa-1, successfully block 99.96% of the diffusion, and extremely low inlet flow opening pressure of 2.1 kPa.

5.
Mater Des ; 150: 182-187, 2018 Jul 15.
Article in English | MEDLINE | ID: mdl-30364619

ABSTRACT

This paper demonstrates a novel and simple processing technique for the realization of scalable and flexible microfluidic microsystems by inkjet-printing polyethylene-glycol (PEG) as a sacrificial template, followed by embedding in a structural layer (e.g. soft elastomers). The printing technology allows production of an array of PEG droplets simultaneously, reducing cost and manufacturing time. The PEG can be removed through heating above its phase-change temperature after the formation of the structural layer, with hydraulic flow removing the material. The developed technique allows easy modulation of the shape and dimensions of the pattern with the ability to generate complex architectures without using lithography. The method produces robust planar and multilayer microfluidic structures that can be realized on wide range of substrates. Moreover, microfluidics can be realized on other systems (e.g. electrodes and transducers) directly without requiring any bonding or assembling steps, which often limit the materials selection in conventional microfluidic fabrication. Multilayer Polydimethylsiloxane (PDMS) microfluidic channels were created using this technique to demonstrate the capability of the concept to realize flexible microfluidic electronics, drug delivery systems, and lab-on-a-chip devices. By utilizing conductive liquid metals (i.e. EGaIn) as the filling material of the channels, flexible passive resistive components and sensors have been realized.

6.
Sci Rep ; 6: 28539, 2016 06 23.
Article in English | MEDLINE | ID: mdl-27335342

ABSTRACT

Highly efficient magnetic release from nanocomposite microparticles is shown, which are made of Poly (N-isopropylacrylamide) hydrogel with embedded iron nanowires. A simple microfluidic technique was adopted to fabricate the microparticles with a high control of the nanowire concentration and in a relatively short time compared to chemical synthesis methods. The thermoresponsive microparticles were used for the remotely triggered release of Rhodamine (B). With a magnetic field of only 1 mT and 20 kHz a drug release of 6.5% and 70% was achieved in the continuous and pulsatile modes, respectively. Those release values are similar to the ones commonly obtained using superparamagnetic beads but accomplished with a magnetic field of five orders of magnitude lower power. The high efficiency is a result of the high remanent magnetization of the nanowires, which produce a large torque when exposed to a magnetic field. This causes the nanowires to vibrate, resulting in friction losses and heating. For comparison, microparticles with superparamagnetic beads were also fabricated and tested; while those worked at 73 mT and 600 kHz, no release was observed at the low field conditions. Cytotoxicity assays showed similar and high cell viability for microparticles with nanowires and beads.

7.
Sensors (Basel) ; 16(5)2016 05 07.
Article in English | MEDLINE | ID: mdl-27164113

ABSTRACT

A magnetoresistive tactile sensor is reported, which is capable of working in high temperatures up to 140 °C. Hair-like bioinspired structures, known as cilia, made out of permanent magnetic nanocomposite material on top of spin-valve giant magnetoresistive (GMR) sensors are used for tactile sensing at high temperatures. The magnetic nanocomposite, consisting of iron nanowires incorporated into the polymer polydimethylsiloxane (PDMS), is very flexible, biocompatible, has high remanence, and is also resilient to antagonistic sensing ambient. When the cilia come in contact with a surface, they deflect in compliance with the surface topology. This yields a change of the GMR sensor signal, enabling the detection of extremely fine features. The spin-valve is covered with a passivation layer, which enables adequate performance in spite of harsh environmental conditions, as demonstrated in this paper for high temperature.

8.
Sci Rep ; 6: 24189, 2016 Apr 13.
Article in English | MEDLINE | ID: mdl-27072595

ABSTRACT

We have synthesized nanowires with an iron core and an iron oxide (magnetite) shell by a facile low-cost fabrication process. The magnetic properties of the nanowires can be tuned by changing shell thicknesses to yield remarkable new properties and multi-functionality. A multi-domain state at remanence can be obtained, which is an attractive feature for biomedical applications, where a low remanence is desirable. The nanowires can also be encoded with different remanence values. Notably, the oxidation process of single-crystal iron nanowires halts at a shell thickness of 10 nm. The oxide shell of these nanowires acts as a passivation layer, retaining the magnetic properties of the iron core even during high-temperature operations. This property renders these core-shell nanowires attractive materials for application to harsh environments. A cell viability study reveals a high degree of biocompatibility of the core-shell nanowires.


Subject(s)
Nanowires/chemistry , Iron/chemistry , Magnetic Fields , Oxidation-Reduction , Temperature
9.
Adv Mater ; 27(47): 7888-92, 2015 Dec 16.
Article in English | MEDLINE | ID: mdl-26487397

ABSTRACT

A multifunctional biomimetic nanocomposite tactile sensor is developed that can detect shear and vertical forces, feel texture, and measure flow with extremely low power consumption. The sensor's high performance is maintained within a wide operating range that can be easily adjusted. The concept works on rigid and flexible substrates and the sensors can be used in air or water without any modifications.

SELECTION OF CITATIONS
SEARCH DETAIL
...