Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Br J Radiol ; 92(1096): 20180793, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30633548

ABSTRACT

OBJECTIVE:: This study aimed to examine the associated factors for dose variation and influence cardiac CT angiography (CCTA) dose benchmarks in current CT imaging centres. METHODS:: A questionnaire was distributed to CT centres across Australia and Saudi Arabia. All participating centres collected data for adults who underwent a CCTA procedure. The questionnaire gathered information about the examination protocol, scanning parameters, patient parameters, and volume CT dose index (CTDI vol) and dose-length product (DLP). A stepwise regression analysis was performed to assess the contribution of tube voltage (kV), padding time technique, cross-sectional area (CSA) of chest and weight to DLP. RESULTS:: A total of 17 CT centres provided data for 423 CCTA examinations. The median CTDIvol, DLP and effective dose were 18 mGy, 256 mGy.cm and 5.2 mSv respectively. There was a statistically significant difference in DLP between retrospective and prospective ECG-gating modes (p = 0.001). Median DLP from CCTA using padding technique was 61% higher than CCTA without padding (p = 0.001). The stepwise regression showed that kV was the most significant predictor of DLP followed by padding technique then CSA while patient weight did not statistically significantly predict DLP. Correlation analysis showed a strong positive correlation between weight and CSA (r = 0.78), and there was a moderate positive correlation between weight and DLP (r = 0.42), as well as CSA and DLP (r = 0.48). CONCLUSION:: Findings show radiation dose variations for CCTA. The associated factors for dose variation found in this study are scanning mode, kV, padding time technique and CSA of the chest. This results support the need to include CSA measurements in future dose survey and for setting DRLs. ADVANCES IN KNOWLEDGE:: The study provides baseline information that helps to understand the associated factors for dose variations and high doses within and between centres performing CCTA.


Subject(s)
Computed Tomography Angiography/methods , Computed Tomography Angiography/statistics & numerical data , Coronary Angiography/methods , Coronary Angiography/statistics & numerical data , Radiation Dosage , Australia , Female , Humans , Male , Middle Aged , Saudi Arabia , Surveys and Questionnaires
2.
Radiat Prot Dosimetry ; 182(4): 525-531, 2018 Dec 01.
Article in English | MEDLINE | ID: mdl-30032302

ABSTRACT

This study aims to assess patient radiation dose from cardiac computed tomography angiography (CCTA) with the aim of proposing a national diagnostic reference levels (NDRLs) for CCTA procedures in Australia. A questionnaire was used to retrospectively gather baseline information related to CCTA scanning and patient parameters in CT centres across the country. The 75th percentile of both volumetric CT dose index (CTDIvol) and dose length-product (DLP) was used as DRL values for CCTA. A DRL for CT calcium scoring test was also determined. NDRLs were compared with international published data. Data sets of 338 patients from nine CT centres were used for analysis. The CCTA DRL for the CTDIvol and the DLP were 22 mGy and 268 mGy cm, respectively. The CT calcium scoring test DRL for DLP was 137 mGy cm. The DRL values for CCTA in Australia have been recommended for the first time. DRLs are lower than those in most published studies due to the implementation of dose-saving technologies such as prospective ECG-gated mode and iterative reconstruction algorithms. Considerable variations remain in patient doses between hospitals for the most frequently used CCTA protocols, indicating the potential for DRLs to prompt dose optimisation strategies in CT facilities.


Subject(s)
Computed Tomography Angiography/standards , Coronary Angiography/standards , Radiation Dosage , Australia , Computed Tomography Angiography/instrumentation , Coronary Angiography/instrumentation , Female , Humans , Male , Middle Aged , Reference Standards , Retrospective Studies , Surveys and Questionnaires
3.
Radiat Prot Dosimetry ; 181(2): 129-134, 2018 Oct 01.
Article in English | MEDLINE | ID: mdl-29351655

ABSTRACT

Cardiac computed tomography angiography (CCTA) is a commonly used diagnostic imaging tool for cardiovascular disease. Despite constant improvements to imaging technologies, the radiation dose to patients remains a concern when using this procedure. Diagnostic reference levels (DRLs) are used as a trigger to identify and alert individual facilities that are using high doses during CT. This study aims to assess patient radiation dose and establish new national DRLs (NDRL) associated with CCTA in Saudi clinical practices. A structured booklet survey was designed for recording patient and scanning protocols during CCTA procedures. The data were collected retrospectively from the participating centres. NDRLs for CCTA were defined as the 75th and 25th of volumetric CT dose index (CTDIvol) and dose length product (DLP). Specific DRLs based on two main ECG-gating modes were also proposed. Data sets related to 197 CCTAs with a mean weight of 77 kg were analysed in detail. The DRL values for CTDIvol and DLP for prospective gating mode and retrospective gating mode were 29 and 62 mGy and 393 and 1057 mGy cm, respectively. NDRLs for CCTA in Saudi Arabia are comparable or slightly lower than European DRLs due to the current use of dose-saving technology. There are major variations in patient doses during CCTA due to differences in CT scanners, scanning modes and departmental CCTA protocols.


Subject(s)
Computed Tomography Angiography/standards , Coronary Angiography/standards , Radiometry/methods , Radiotherapy Planning, Computer-Assisted/methods , Adult , Computed Tomography Angiography/methods , Female , Humans , Male , Middle Aged , Prospective Studies , Radiation Dosage , Radiotherapy, Intensity-Modulated/methods , Reference Values , Retrospective Studies , Saudi Arabia
4.
Radiat Prot Dosimetry ; 178(1): 63-72, 2018 Jan 01.
Article in English | MEDLINE | ID: mdl-28591861

ABSTRACT

Cardiac computed tomography angiography (CCTA) is a commonly used diagnostic tool for cardiovascular disease. Despite constant improvements to imaging technologies, the radiation dose to patients from CCTA remains a concern when using this procedure. There remains a need for optimisation of CCTA procedures and accurate dose monitoring to reduce the potential risk of cancer. Establishing diagnostic reference levels (DRLs) allows for the assessment of radiation dose variations, enabling strategies aimed at standardising doses across radiological centres. This systematic review explores the literature on CCTA methodologies that have been used to establish DRLs. A search was carried out using the Web of Science, SCOPUS, Medline, CINAHL and EMBASE databases. Reference lists of published articles were also assessed to identify further articles. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) methodology was employed to evaluate articles for relevance. Articles were included if they assessed DRLs in CCTA. The search resulted in 448 articles, of which, six were included after a thorough screening process. The literature demonstrates a wide dose variation in reported CCTA DRLs ranging from 671 to 1510 mGy cm in DLP. Where reported, CTDIvol DRLs ranged from 26 to 70 mGy. Differences were found in the methodologies used for establishing CCTA DRLs, including the sampling methodology used for identifying suitable patients and scanning protocols. This current review emphasises the need for an international standardisation for DRLs establishment methods, to provide a more comparable global measurement of dose variations across CT sites.


Subject(s)
Computed Tomography Angiography , Coronary Angiography , Radiation Dosage , Humans , Radiometry/methods , Reference Values
SELECTION OF CITATIONS
SEARCH DETAIL
...