Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 85
Filter
2.
J Cardiovasc Electrophysiol ; 35(3): 601-607, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38287171

ABSTRACT

The subcutaneous implantable cardioverter defibrillator (S-ICD) was developed as an alternative to the traditional transvenous implantable cardioverter defibrillator (TV-ICD), aiming to provide easier implantation, simplified detection algorithm of malignant ventricular arrhythmias and prevention from placing components in the cardiovascular system. The S-ICD is implanted subcutaneously or intramuscularly with the generator placed in the left midaxillary line and the lead tunneled subcutaneously in the left para-sternal region. Preimplant electrocardiogram screening is recommended to prevent implantation in patients at high risk of T wave over-sensing. Currently, the S-ICD is unsuitable for patients requiring pacing or cardiac resynchronization. Since the beginning, the S-ICD underwent extensive preclinical investigation until the first prospective multicentre trial demonstrating high efficacy and safety led to market release. While earlier studies focused on younger patients with higher ejection fraction, more recent studies showed favorable outcomes even in patients with comorbidities similar to those typically observed in patients receiving TV-ICD. The development of second and third generation devices has contributed to reduce inappropriate shocks and overcome previous limitations. The aim of this paper is to review the evidence in the literature over the past decade supporting S-ICD as a valid alternative to TV-ICD in terms of safety and efficacy, highlighting the improvements in technology, as well as outcomes.


Subject(s)
Death, Sudden, Cardiac , Defibrillators, Implantable , Humans , Death, Sudden, Cardiac/prevention & control , Prospective Studies , Treatment Outcome , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/therapy , Arrhythmias, Cardiac/etiology , Defibrillators, Implantable/adverse effects , Multicenter Studies as Topic
4.
JAMA Cardiol ; 9(1): 91-92, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37966819

ABSTRACT

A man in his 50s with recurrent palpitations, fatigue, and progressive exertion dyspnea had irregular narrow-QRS tachycardia in an incessant, repetitive fashion with heart rates up to 180 beats per minute and occasional short runs of wide-QRS tachycardia on Holter monitoring and 12-lead electrocardiogram. What would you do next?


Subject(s)
Heart Failure , Male , Middle Aged , Humans , Heart Failure/diagnosis , Heart Failure/etiology , Electrocardiography
5.
J Clin Med ; 12(21)2023 Nov 02.
Article in English | MEDLINE | ID: mdl-37959373

ABSTRACT

Despite progress in implantation technology and prophylactic measures, infection complications related to cardiac implantable electronic devices (CIED) are still a major concern with negative impacts on patient outcomes and the health system's resources. Infective endocarditis (IE) represents one of the most threatening CIED-related infections associated with high mortality rates and requires prompt diagnosis and management. Transvenous lead extraction (TLE), combined with prolonged antibiotic therapy, has been validated as an effective approach to treat patients with CIED-related IE. Though early complete removal is undoubtedly recommended for CIED-related IE or systemic infection, device reimplantation still represents a clinical challenge in these patients at high risk of reinfection, with many gaps in the current knowledge and international guidelines. Based on the available literature data and authors' experience, this review aims to address the practical and clinical considerations regarding CIED reimplantation following lead extraction for related IE, focusing on the reassessment of CIED indication, procedure timing, and the reimplanted CIED type and site. A tailored, multidisciplinary approach involving clinical cardiologists, electrophysiologists, cardiac imaging experts, cardiac surgeons, and infectious disease specialists is crucial to optimize these patients' management and clinical outcomes.

6.
J Cardiovasc Electrophysiol ; 34(11): 2316-2329, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37655997

ABSTRACT

The right bundle branch (RBB), due to its endocardial course, is susceptible to traumatic block caused by "bumping" during right-heart catheterization. In the era of cardiac electrophysiology, catheter-induced RBB block (CI-RBBB) has become a common phenomenon observed during electrophysiological studies and catheter ablation procedures. While typically transient, it may persist for the entire procedure time. Compared to pre-existing RBBB, the transient nature of CI-RBBB allows for comparative analysis relative to the baseline rhythm. Furthermore, unlike functional RBBB, it occurs at similar heart rates, making the comparison of conduction intervals more reliable. While CI-RBBB can provide valuable diagnostic information in various conditions, it is often overlooked by cardiac electrophysiologists. Though it is usually a benign and self-limiting conduction defect, it may occasionally lead to diagnostic difficulties, pitfalls, or undesired consequences. Avoidance of CI-RBBB is advised in the presence of baseline complete left bundle branch block and when approaching arrhythmic substrates linked to the right His-Purkinje-System, such as fasciculo-ventricular pathways, bundle branch reentry, and right-Purkinje focal ventricular arrhythmias. This article aims to provide a comprehensive practical review of the electrophysiological phenomena related to CI-RBBB and its impact on the intrinsic conduction system and various arrhythmic substrates.


Subject(s)
Bundle-Branch Block , Heart Conduction System , Humans , Bundle-Branch Block/diagnosis , Bundle-Branch Block/etiology , Heart Conduction System/surgery , Heart Ventricles , Cardiac Catheterization/adverse effects , Catheters , Electrocardiography
7.
Pacing Clin Electrophysiol ; 46(10): 1230-1234, 2023 10.
Article in English | MEDLINE | ID: mdl-36788778

ABSTRACT

Catheter ablation (CA) of left atrial tachycardia adjacent to implanted septal closure devices represents a multifaceted challenge. We describe the case of a 57-year-old patient with remote percutaneous closure of atrial septal defect who underwent successful CA of left atrial tachycardia adjacent to the septal device using a transaortic approach and RF energy. Besides the technical difficulties and associated risks, interference between the device and applied RF parameters may limit ablation efficiency. Further research is required to evaluate the safety, efficacy, and optimal energy type/parameters when ablating arrhythmias adjacent to these devices.


Subject(s)
Catheter Ablation , Heart Septal Defects, Atrial , Tachycardia, Supraventricular , Humans , Middle Aged , Tachycardia/surgery , Tachycardia, Supraventricular/surgery , Arrhythmias, Cardiac/surgery , Heart Septal Defects, Atrial/surgery , Treatment Outcome
8.
J Interv Card Electrophysiol ; 66(8): 1877-1888, 2023 Nov.
Article in English | MEDLINE | ID: mdl-36795268

ABSTRACT

BACKGROUND: To predict the outflow tract ventricular arrhythmias (OTVA) site of origin (SOO) before the ablation procedure has important practical implications. The present study sought to prospectively evaluate the accuracy of a clinical and electrocardiographic hybrid algorithm (HA) for the prediction of OTVAs-SOO, and at the same time to develop and to prospectively validate a new score with improved discriminatory capacity. METHODS: In this multicenter study, we prospectively enrolled consecutive patients referred for OTVA ablation (N = 202), and we divided them in a derivation sample and a validation cohort. Surface ECGs during OTVA were analyzed to compare previous published ECG-only criteria and to develop a new score. RESULTS: In the derivation sample (N = 105), the correct prediction rate of HA and ECG-only criteria ranged from 74 to 89%. R-wave amplitude in V3 was the best ECG parameter for discriminating LVOT origin in V3 precordial transition (V3PT) patients, and was incorporated to the novel weighted hybrid score (WHS). WHS correctly classified 99 (94.2%) patients, presenting 90% sensitivity and 96% specificity (AUC 0.97) in the entire population; WHS mantained a 87% sensitivity and 91% specificity (AUC 0.95) in patients with V3PT subgroup. The high discriminatory capacity was confirmed in the validation sample (N = 97): the WHS exhibited an AUC (0.93), and a WHS ≥ 2 allowed a correct prediction of LVOT origin in 87 (90.0%) cases, yielding a sensitivity of 87% and specificity of 90%; moreover, the V3PT subgroup showed an AUC of 0.92, and a punctuation ≥ 2 predicted an LVOT origin with a sensitivity of 94% and specificity of 78%. CONCLUSIONS: The novel hybrid score has proved to accurately anticipate the OTVA's origin, even in those with a V3 precordial transition. A Weighted hybrid score. B Typical examples of the use of the weighted hybrid score. C ROC analysis of WHS and previous ECG criteria for prediction of LVOT origin in the derivation cohort. D ROC analysis of WHS and previous ECG criteria for prediction of LVOT origin in the V3 precordial transition OTVA subgroup.

9.
J Cardiovasc Electrophysiol ; 34(3): 598-606, 2023 03.
Article in English | MEDLINE | ID: mdl-36640425

ABSTRACT

INTRODUCTION: Despite numerous ECG algorithms being developed to localize the site of manifest accessory pathways (AP), they often require stepwise multiple-lead analysis with variable accuracy, limitations, and reproducibility. The study aimed to develop a single-lead ECG algorithm incorporating the P-Delta interval (PDI) as an adjunct criterion to discriminate between right and left manifest AP. METHODS: Consecutive WPW patients undergoing electrophysiological study (EPS) were retrospectively recruited and split into a derivation and validation group (1:1 ratio). Sinus rhythm ECG analysis in lead V1 was performed by three independent investigators blinded to the EPS results. Conventional ECG parameters and PDI were assessed through the global cohort. RESULTS: A total of 140 WPW patients were included (70 for each group). A score-based, single-lead ECG algorithm was developed through derivation analysis incorporating the PDI, R/S ratio, and QRS onset polarity in lead V1. The validation group analysis confirmed the proposed algorithm's high accuracy (95%), which was superior to the previous ones in predicting the AP side (p < 0.05). A score of ≤+1 was 96.5% accurate in predicting right AP while a score of ≥+2 was 92.5% accurate in predicting left AP. The new algorithm maintained optimal performance in specific subgroups of the global cohort showing an accuracy rate of 90%, 92%, and 96% in minimal pre-excitation, posteroseptal AP, and pediatric patients, respectively. CONCLUSIONS: A novel single-lead ECG algorithm incorporating the PDI interval with previous conventional criteria showed high accuracy in differentiating right from left manifest AP comprising pediatric and minimal pre-excitation subgroups in the current study.


Subject(s)
Accessory Atrioventricular Bundle , Catheter Ablation , Wolff-Parkinson-White Syndrome , Humans , Child , Retrospective Studies , Reproducibility of Results , Catheter Ablation/methods , Electrocardiography/methods , Algorithms , Wolff-Parkinson-White Syndrome/surgery
10.
Int J Cardiol ; 375: 23-28, 2023 03 15.
Article in English | MEDLINE | ID: mdl-36587656

ABSTRACT

BACKGROUND: This study aimed to collect and analyze the literature data regarding Chiari network (CN) and other right atrium (RA) remnants comprising the Eustachian and Thebesian valves (EV, ThV) as a potential entrapment site during different percutaneous cardiac procedures (PCP). METHODS AND RESULTS: A systematic search was conducted using Pubmed and Embase databases following the PRISMA guidelines to obtain available data concerning PCP associated with entrapment of inserted materials within CN-EV-ThV. The final analysis included 41 patients who underwent PCP with reported material entrapment within these RA remnants. The PCP was atrial septal defect (ASD)/patent foramen ovale (PFO) closure, catheter ablation, and pacemaker/defibrillator implantation in 44%, 22%, and 17% of patients, respectively. The entrapped materials were ASD/PFO devices, multipolar electrophysiology catheters, passive-fixation pacing leads, and J-guidewires in about 30%, 20%, 15%, and 10% of patients, respectively. Intraprocedural transthoracic, transoesophageal and intracardiac echocardiography showed sensitivity to reveal these structures of 20%, ∼95%, and 100%, respectively. A percutaneous approach successfully managed 70% of patients, while cardiovascular surgery was required in 20% and three patients died (7.3%). CONCLUSIONS: CN and other RA remnants may cause entrapment of various devices or catheters during PCP requiring right heart access. The percutaneous approach, guided by intraprocedural imaging, appears safe and effective in managing most patients. Prevention includes recognizing these anatomical structures at baseline cardiac imaging and intraprocedural precautions. Further studies are needed to analyze the actual incidence of this condition, its clinical impact and appropriate management.


Subject(s)
Cardiologists , Foramen Ovale, Patent , Heart Septal Defects, Atrial , Humans , Cardiac Catheterization/methods , Heart Septal Defects, Atrial/diagnostic imaging , Heart Septal Defects, Atrial/epidemiology , Foramen Ovale, Patent/diagnostic imaging , Foramen Ovale, Patent/epidemiology , Foramen Ovale, Patent/surgery , Heart Atria/diagnostic imaging , Heart Atria/surgery , Prostheses and Implants , Treatment Outcome
11.
Minerva Cardiol Angiol ; 71(6): 622-630, 2023 Dec.
Article in English | MEDLINE | ID: mdl-36305779

ABSTRACT

INTRODUCTION: To evaluate the clinical outcomes of oral mexiletine (oMXT) to treat ventricular tachyarrhythmias (VTAs) in the era of implantable cardioverter-defibrillator (ICD) technology. EVIDENCE ACQUISITION: A systematic search was conducted using PubMed, Embase and Cochrane databases following the PRISMA guidelines to collect literature data reporting oMXT efficacy and safety outcomes in treating VTAs in ICD recipients. EVIDENCE SYNTHESIS: Final analysis included four studies accounting for a total of 91 patients with recurrent VTAs treated with oMXT. Amiodarone therapy was initially attempted in most patients (91.2%), while catheter ablation was performed in one-third of patients. VTA recurrences were observed in 55/91 patients (60.4%) during oMXT treatment compared to 91/91 (100%) before treatment (P<0.001). Appropriate therapies occurred in 55/88 ICD patients (62.5%) during oMXT treatment compared to 80/88 (90.9%) before treatment (P<0.001). After oMXT introduction, there was a significant reduction of the individual burden of VTA episodes and appropriate ICD therapies per patient, showing Hedges'g values of -1.103 (P=0.002) and -1.474 (P=0.008), respectively. Safety analysis showed a sample-weighted overall side-effect rate of 30%, while 21% of patients required drug reduction or discontinuation. Aggregated meta-regression analysis of the included studies and remote literature revealed a linear correlation between oMXT dosage and the overall side effects rate (r2 = 0.48; P=0.014). CONCLUSIONS: Oral mexiletine provides an adjunctive treatment to manage VTAs and reduces appropriate therapies in ICD patients with moderate efficacy and acceptable safety profiles. These observations await confirmation through randomised clinical trials.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Mexiletine/therapeutic use , Defibrillators, Implantable/adverse effects , Anti-Arrhythmia Agents/adverse effects , Treatment Outcome , Tachycardia, Ventricular/drug therapy
14.
Europace ; 24(10): 1608-1616, 2022 10 13.
Article in English | MEDLINE | ID: mdl-35639806

ABSTRACT

AIMS: Air entrapment (AE) has been reported as a potential cause of early inappropriate shocks (ISs) following subcutaneous implantable cardioverter defibrillator (S-ICD) implantation, but a cause-effect relationship is not always evident. This systematic review aims to analyse this phenomenon concerning implantation techniques, electrogram (EGM) features, radiologic findings, and patient management. METHODS AND RESULTS: A systematic search was conducted using PubMed, Embase, and Google Scholar databases following the PRISMA guidelines to obtain all available literature data since 2010 on S-ICD malfunctions possibly due to AE. The final analysis included 54 patients with AE as a potential cause of S-ICD malfunction. Overall, the aggregate incidence of this condition was 1.2%. Of ICD malfunctions possibly due to AE, 93% were ISs, and 95% were recorded within the first week following implantation. Radiologic diagnosis of AE was confirmed in 28% of the entire study cohort and in 68% of patients in whom this diagnostic examination was reported. At the time of device malfunction, EGMs showed artefacts, baseline drift, and QRS voltage reduction in 95, 76, and 67% of episodes, respectively. Management included ICD reprogramming or testing, no action (observation), and invasive implant revision in 57, 33, and 10% of patients, respectively. No recurrences occurred during follow-up, irrespective of management performed. CONCLUSIONS: Device malfunction possibly due to AE may occur in ∼1% of S-ICD recipients. Diagnosis is strongly suggested by early occurrence, characteristic EGM features, and radiologic findings. Non-invasive management, principally device reprogramming, appears to be effective in most patients.


Subject(s)
Defibrillators, Implantable , Cohort Studies , Defibrillators, Implantable/adverse effects , Humans , Incidence , Treatment Outcome
20.
Circ Arrhythm Electrophysiol ; 14(1): e008073, 2021 01.
Article in English | MEDLINE | ID: mdl-33441001

ABSTRACT

Surveys and registries are widely used in medicine as valuable tools to integrate the information from randomized and observational studies. Early after its introduction in daily practice and parallel to its escalating popularity, catheter ablation of atrial fibrillation has been the subject of several surveys and registries. Over the years, relevant aspects associated with atrial fibrillation ablation have been investigated using these tools, including procedural safety and efficacy, discontinuation of anticoagulation therapy and risk of stroke postablation, and outcomes in special populations. The aim of this article is to provide a comprehensive review of the contributions offered by surveys and registries in catheter ablation of atrial fibrillation over the past 15 years.


Subject(s)
Atrial Fibrillation/surgery , Catheter Ablation/methods , Forecasting , Registries , Risk Assessment/methods , Stroke/prevention & control , Atrial Fibrillation/complications , Atrial Fibrillation/physiopathology , Follow-Up Studies , Global Health , Humans , Incidence , Risk Factors , Stroke/epidemiology , Stroke/etiology
SELECTION OF CITATIONS
SEARCH DETAIL
...