Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Language
Publication year range
1.
Med. oral patol. oral cir. bucal (Internet) ; 24(6): e764-e769, nov. 2019. ilus, graf
Article in English | IBECS | ID: ibc-192237

ABSTRACT

BACKGROUND: Surgical fixation of implants into bone for the correction of bone deformities or defects is a traditional approach for skeletal stabilization. Important measures of efficacy of implants include implant stability and osseo integration-the direct interaction between living bone and an implant. Osseointegration depends on successful implant placement and subsequent bone remodeling. This study utilized osseo densification drilling (OD) in a low bone density model using trabecular metal (TM) implants. MATERIAL AND METHODS: Three osteotomy sites, Regular, OD-CW (clockwise), and OD-CCW (counterclockwise), were prepared in each ilium of three female sheep. Drilling was performed at 1100rpm with saline irrigation. Trabecular metal (TM) (Zimmer(R), Parsippany, NJ, USA) implants measuring 3.7mm in diameter X 10mm length were placed into respective osteotomies. A three-week period post-surgery was given to allow for healing to take place after which all three sheep were euthanized and the ilia were collected. Samples were prepared, qualitatively and quantitatively analyzed using histology micrographs and image analysis software (ImageJ, NIH, Bethesda, MD). Bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO) were quantified to evaluate the osseointegration parameters. RESULTS: All implants exhibit successful bone formation in the peri-implant environment as well as within the open spaces of the trabecular network. Osseointegration within the TM (quantified by %BIC) as a function of drilling technique was more pronounced in OD samples (p > 0.05). The %BAFO however shows a significant difference (p = 0.036) between the CCW and R samples. Greater bone volume and frequency of bone chips are observed in OD samples. CONCLUSION: The utilization of OD as a design for improved fixation of hardware was supported by increased levels of stability, both primary and secondary. Histological data with OD provided notably different results from those of the regular drilling method


No disponible


Subject(s)
Animals , Female , Dental Implantation, Endosseous , Osseointegration , Osteogenesis , Osteotomy , Tantalum , Models, Animal , Sheep
2.
J Orthop Res ; 37(12): 2499-2507, 2019 12.
Article in English | MEDLINE | ID: mdl-31334868

ABSTRACT

There are over two million long bone defects treated in the United States annually, of which ~5% will not heal without significant surgical intervention. While autogenous grafting is the standard of care in simple defects, a customized scaffold for large defects in unlimited quantities is not available. Recently, a three-dimensionally (3D)-printed bioactive ceramic (3DPBC) scaffold has been successfully utilized in the of repair critical-sized (CSD) long bone defects in vivo. In this study, 3DPBC scaffolds were augmented with dipyridamole (DIPY), an adenosine A2A receptor (A2A R) indirect agonist, because of its known effect to enhance bone formation. CSD full thickness segmental defects (~11 mm × full thickness) defects were created in the radial diaphysis in New Zealand white rabbits (n = 24). A customized 3DPBC scaffold composed of ß-tricalcium phosphate was placed into the defect site. Groups included scaffolds that were collagen-coated (COLL), or immersed in 10, 100, or 1,000 µM DIPY solution. Animals were euthanized 8 weeks post-operatively and the radii/ulna-scaffold complex retrieved en bloc, for micro-CT, histological, and mechanical analysis. Bone growth was assessed exclusively within scaffold pores and evaluated by microCT and advanced reconstruction software. Biomechanical properties were evaluated utilizing nanoindentation to assess the newly regenerated bone for elastic modulus (E) and hardness (H). MicroCT reconstructions illustrated bone in-growth throughout the scaffold, with an increase in bone volume dependent on the DIPY dosage. The histological evaluation did not indicate any adverse immune response while revealing progressive remodeling of bone. These customized biologic 3DPBC scaffolds have the potential of repairing and regenerating bone. © 2019 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:2499-2507, 2019.


Subject(s)
Bone Regeneration , Dipyridamole/pharmacology , Printing, Three-Dimensional , Tissue Scaffolds , Animals , Ceramics , Female , Osteogenesis , Rabbits , X-Ray Microtomography
3.
J Orthop Res ; 36(9): 2516-2523, 2018 09.
Article in English | MEDLINE | ID: mdl-29537128

ABSTRACT

Osseointegration, the direct functional and structural connection between device and bone is influenced by multiple factors such as implant macrogeometry and surgical technique. This study investigated the effects of osseodensification drilling techniques on implant stability and osseointegration using trabecular metal (TM) and tapered-screw vent (TSV) implants in a low-density bone. Six skeletally mature sheep were used where six osteotomy sites were prepared in each of the ilia, (n = 2/technique: Regular [R] (subtractive), clockwise [CW], and counterclockwise [CCW]). One TM and one TSV implant was subsequently placed with R osteotomy sites prepared using a conventional (subtractive) drilling protocol as recommended by the implant manufacturer for low density bone. CW and CCW drilling sites were subjected to osseodensification (OD) (additive) drilling. Evaluation of insertion torque as a function of drilling technique showed implants subjected to R drilling yielded a significant lower insertion torque relative to samples implanted in OD (CW/CCW) sites (p < 0.05). Histomorphometric analysis shows that the osseodensification demonstrates significantly greater values for bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Histological analysis shows the presence of bone remnants, which acted as nucleating surfaces for osteoblastic bone deposition, facilitating the bridging of bone between the surrounding native bone and implant surface, as well as within the open spaces of the trabecular network in the TM implants. Devices that were implanted via OD demonstrated atemporal biomechanical stability and osseointegration. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2516-2523, 2018.


Subject(s)
Bone Density , Bone Screws , Metals/chemistry , Osseointegration , Osteoblasts/metabolism , Osteotomy/methods , Animals , Materials Testing , Orthopedics , Prosthesis Design , Sheep , Torque
4.
J Mech Behav Biomed Mater ; 69: 275-281, 2017 05.
Article in English | MEDLINE | ID: mdl-28113132

ABSTRACT

Integration between implant and bone is an essential concept for osseous healing requiring hardware placement. A novel approach to hardware implantation, termed osseodensification, is described here as an effective alternative. 12 sheep averaging 65kg had fixation devices installed in their C2, C3, and C4 vertebral bodies; each device measured 4mm diameter×10mm length. The left-sided vertebral body devices were implanted using regular surgical drilling (R) while the right-sided devices were implanted using osseodensification drilling (OD). The C2 and C4 vertebra provided the t=0 in vivo time point, while the C3 vertebra provided the t=3 and t=6 week time points, in vivo. Structural competence of hardware was measured using biomechanical testing of pullout strength, while the quality and degree of new bone formation and remodeling was assessed via histomorphometry. Pullout strength demonstrated osseodensification drilling to provide superior anchoring when compared to the control group collapsed over time with statistical significance (p<0.01). On Wilcoxon rank signed test, C2 and C4 specimens demonstrated significance when comparing device pullout (p=0.031) for both, and C3 pullout tests at 3 and 6 weeks collapsed over time had significance as well (p=0.027). Percent bone-to-implant contact (%BIC) analysis as a function of drilling technique demonstrated an OD group with significantly higher values relative to the R group (p<0.01). Similarly, percent bone-area-fraction-occupancy (BAFO) analysis presented with significantly higher values for the OD group compared to the R group (p=0.024). As a function of time, between 0 and 3 weeks, a decrease in BAFO was observed, a trend that reversed between 3 and 6 weeks, resulting in a BAFO value roughly equivalent to the t=0 percentage, which was attributed to an initial loss of bone fraction due to remodeling, followed by regaining of bone fraction via production of woven bone. Histomorphological data demonstrated autologous bone chips in the OD group with greater frequency relative to the control, which acted as nucleating surfaces promoting new bone formation around the implants, providing superior stability and greater bone density. This alternative approach to a critical component of hardware implantation encourages assessment of current surgical approaches to hardware implantation.


Subject(s)
Bone Density , Cervical Vertebrae , Internal Fixators , Spinal Fusion , Animals , Biomechanical Phenomena , Bone Screws , Sheep
5.
J Mech Behav Biomed Mater ; 63: 56-65, 2016 10.
Article in English | MEDLINE | ID: mdl-27341291

ABSTRACT

A bone drilling concept, namely osseodensification, has been introduced for the placement of endosteal implants to increase primary stability through densification of the osteotomy walls. This study investigated the effect of osseodensification on the initial stability and early osseointegration of conical and parallel walled endosteal implants in low density bone. Five male sheep were used. Three implants were inserted in the ilium, bilaterally, totaling 30 implants (n=15 conical, and n=15 parallel). Each animal received 3 implants of each type, inserted into bone sites prepared as follows: (i) regular-drilling (R: 2mm pilot, 3.2mm, and 3.8mm twist drills), (ii) clockwise osseodensification (CW), and (iii) counterclockwise (CCW) osseodensification drilling with Densah Bur (Versah, Jackson, MI, USA): 2.0mm pilot, 2.8mm, and 3.8mm multi-fluted burs. Insertion torque as a function of implant type and drilling technique, revealed higher values for osseodensification relative to R-drilling, regardless of implant macrogeometry. A significantly higher bone-to-implant contact (BIC) for both osseodensification techniques (p<0.05) was observed compared to R-drilling. There was no statistical difference in BIC as a function of implant type (p=0.58), nor in bone-area-fraction occupancy (BAFO) as a function of drilling technique (p=0.22), but there were higher levels of BAFO for parallel than conic implants (p=0.001). Six weeks after surgery, new bone formation along with remodeling sites was observed for all groups. Bone chips in proximity with the implants were seldom observed in the R-drilling group, but commonly observed in the CW, and more frequently under the CCW osseodensification technique. In low-density bone, endosteal implants present higher insertion torque levels when placed in osseodensification drilling sites, with no osseointegration impairment compared to standard subtractive drilling methods.


Subject(s)
Bone Density , Ilium/physiology , Osseointegration , Prostheses and Implants , Animals , Bone-Implant Interface , Male , Osteotomy , Sheep , Torque
SELECTION OF CITATIONS
SEARCH DETAIL
...