Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Res Sq ; 2024 Jul 02.
Article in English | MEDLINE | ID: mdl-39011111

ABSTRACT

CryoEM democratization is hampered by access to costly plunge-freezing supplies. We introduce methods, called CryoCycle, for reliably blotting, vitrifying, and reusing clipped cryoEM grids. We demonstrate that vitreous ice may be produced by plunging clipped grids with purified proteins into liquid ethane and that clipped grids may be reused several times for different protein samples. Furthermore, we demonstrate the vitrification of thin areas of cells prepared on gold-coated, pre-clipped grids.

2.
bioRxiv ; 2024 May 13.
Article in English | MEDLINE | ID: mdl-38328036

ABSTRACT

CryoEM democratization is hampered by access to costly plunge-freezing supplies. We introduce methods, called CryoCycle, for reliably blotting, vitrifying, and reusing clipped cryoEM grids. We demonstrate that vitreous ice may be produced by plunging clipped grids with purified proteins into liquid ethane and that clipped grids may be reused several times for different protein samples. Furthermore, we demonstrate the vitrification of thin areas of cells prepared on gold-coated, pre-clipped grids.

3.
Nat Methods ; 21(4): 562-565, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38238558

ABSTRACT

Imaging large fields of view at a high magnification requires tiling. Transmission electron microscopes typically have round beam profiles; therefore, tiling across a large area is either imperfect or results in uneven exposures, a problem for dose-sensitive samples. Here, we introduce a square electron beam that can easily be retrofitted in existing microscopes, and demonstrate its application, showing that it can tile nearly perfectly and deliver cryo-electron microscopy imaging with a resolution comparable to conventional set-ups.


Subject(s)
Cryoelectron Microscopy , Cryoelectron Microscopy/methods , Microscopy, Electron, Transmission
4.
bioRxiv ; 2023 Oct 09.
Article in English | MEDLINE | ID: mdl-37873376

ABSTRACT

Imaging large fields of view at a high magnification requires tiling. Transmission electron microscopes typically have round beam profiles; therefore, tiling across a large area is either imperfect or results in uneven exposures, a problem on dose-sensitive samples. Here, we introduce a square electron beam that can be easily retrofitted in existing microscopes and demonstrate its application, showing it can tile nearly perfectly and deliver cryo-EM imaging with a resolution comparable to conventional setups.

5.
Res Sq ; 2023 Aug 09.
Article in English | MEDLINE | ID: mdl-37609243

ABSTRACT

Imaging large fields-of-view at a high magnification requires tiling. Transmission electron microscopes typically have round beam profiles; therefore, tiling across a large field-of-view is either imperfect or results in uneven exposures, which is a problem on dose-sensitive samples. Here we introduce a square electron beam that can be easily retrofitted in existing microscopes and demonstrate its application showing it can tile nearly perfectly and deliver cryo-EM imaging with resolution comparable to conventional setups.

6.
Microsc Microanal ; 29(29 Suppl 1): 949-950, 2023 Jul 22.
Article in English | MEDLINE | ID: mdl-37613800
7.
J Struct Biol ; 204(2): 270-275, 2018 11.
Article in English | MEDLINE | ID: mdl-30055234

ABSTRACT

Automated data acquisition is used widely for single-particle reconstruction of three-dimensional (3D) volumes of biological complexes preserved in vitreous ice and imaged in a transmission electron microscope. Automation has become integral to this method because of the very large number of particle images required in order to overcome the typically low signal-to-noise ratio of these images. For optimal efficiency, automated data acquisition software packages typically employ some beam-image shift targeting as this method is both fast and accurate (±0.1 µm). In contrast, using only stage movement, relocation to a targeted area under low-dose conditions can only be achieved in combination with multiple iterations or long relaxation times, both reducing efficiency. Nevertheless it is well known that applying beam-image shift induces beam-tilt and with it a potential structure phase error with a phase error π/4 the highest acceptable value. This theory has been used as an argument against beam-image shift for high resolution data collection. Nevertheless, in practice many small beam-image shift datasets have resulted in 3D reconstructions beyond the π/4 phase error limit. To address this apparent contradiction, we performed cryo-EM single-particle reconstructions on a T20S proteasome sample using applied beam-image shifts corresponding to beam tilts from 0 to 10 mrad. To evaluate the results we compared the FSC values, and examined the water density peaks in the 3D map. We conclude that the phase error does not limit the validity of the 3D reconstruction from single-particle averaging beyond the π/4 resolution limit.


Subject(s)
Cryoelectron Microscopy/methods , Algorithms , Signal-To-Noise Ratio
SELECTION OF CITATIONS
SEARCH DETAIL
...