Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
Ultrason Sonochem ; 77: 105696, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34358883

ABSTRACT

A novel, green and eco-friendly, cost-effective, fast, and reliable high energy ultrasonication (US) extraction with UHPLC-MSMS (Ultrahigh performance liquid chromatography with mass spectrometry) quantification of Glycyrrhizic acid (GZA) is reported herein for the first time. The study provides useful insights regarding the effect of US-factors with statistical analysis and mechanisms, involved in GZA-extraction and analysis. An US-extraction method (US-MD) was developed using three levels of US factors: solvents (AC (acetone), EtOH (ethanol), H2O (water)), time (1, 2, 3 min), amplitudes (30, 40, 50%), pulse (10/0.5, 20/0.5, 30/0.5 sec), particle sizes (0.5, 1, 1.4 mm), and temperatures (20, 30, 40 °C). The US-MD was further validated with high accuracy 98.96 ± 6.82 and r2 = 0.995 whereas, an in-house analytical method (UHPLC-MSMS) was developed and validated to quantify the GZAamount. UHPLCMSMS-MD resulted in a retention time of 0.31 min with MSMS (821.400 > 351.200) in a 1 min run time whereas, UHPLCMSMS-MV showed high accuracy and precision with r2 = 0.998 for GZA. Statistical analysis of K-mean clustering finalized US-set-of-factors showing optimum extract yield (mg/1mg) of 0.48 with sum (2.41 ± 014) and mean (0.27) along with a high GZA-amount (µg/mg) of 8.23 with sum (43.31 ± 2.07) and mean (4.81) for H2O in 3 min at 40 °C using particle size (1.4 mm), amplitude (50%), and pulse (30/0.5). Large scale application of US-UHPLCMSMS confirmed the evaluation power of the method showing the order for GZA amount; Egypt > Pakistan > Syria > India > Palestine > America > Georgia > Morocco. A significant effect for US factors Vs extract yield and GZA amount was observed however, solvent*GZA-amount and extract yield*particle size were more significantly correlated compared to time*temperature*amplitude*pulse analyzed via PCA, GLM-UniANOVA, K-mean, and Pearson's correlation (P ≤ 0.05). A combined mechanism of shear stress, macroturbulence due to acoustic cavitation and implosions, sonochemical, and sonocapillary effect were noted for the US technique producing higher extract yield and GZA amount from licorice.


Subject(s)
Chemical Fractionation/methods , Chromatography, High Pressure Liquid , Glycyrrhiza/chemistry , Glycyrrhizic Acid/analysis , Glycyrrhizic Acid/isolation & purification , Tandem Mass Spectrometry , Ultrasonic Waves , Green Chemistry Technology , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...