Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Herzschrittmacherther Elektrophysiol ; 34(4): 278-285, 2023 Dec.
Article in German | MEDLINE | ID: mdl-37861731

ABSTRACT

Atrioventricular nodal reentrant tachycardia (AVNRT) and atrioventricular reentrant tachycardia in patients with accessory pathways (AP) are common supraventricular tachycardias. High long-term efficacy of about 97% (AVNRT) and 92% (AP) has been observed in children and adults. The risk of occurring atrioventricular block is low (0.4-0.8% during AVNRT, 0.1-0.2% for AP). Catheter ablation shows a lower efficacy of 87-93% and elevated atrioventricular block risk up to 10% in patient groups with complex congenital heart disease. Nonsynchronized ventricular activation during preexcitation or permanent reentrant tachycardias can induce heart failure, and remission of left ventricular function can be expected in > 90% after successful catheter ablation. Therefore, catheter ablation is the long-term therapy of choice for AVNRT and AP with high efficacy and safety for most patient populations.


Subject(s)
Accessory Atrioventricular Bundle , Atrioventricular Block , Catheter Ablation , Tachycardia, Atrioventricular Nodal Reentry , Tachycardia, Supraventricular , Adult , Child , Humans , Tachycardia, Atrioventricular Nodal Reentry/diagnosis , Tachycardia, Atrioventricular Nodal Reentry/surgery , Accessory Atrioventricular Bundle/surgery , Catheter Ablation/methods , Electrocardiography
2.
Clin Res Cardiol ; 2023 Sep 15.
Article in English | MEDLINE | ID: mdl-37710016

ABSTRACT

BACKGROUND: Atrial tachycardias (AT) occurring in patients after previous atrial fibrillation (AF) ablation are increasingly observed in clinical practice. Catheter ablation is the treatment of choice but an optimal workflow to improve patient outcome has not been defined. The purpose of this study was to assess procedural and clinical outcome depending on baseline rhythm at the beginning of AT ablation. METHODS: A total of 380 patients (69 (61-75) years, 56.6% male) who underwent catheter ablation for consecutive AT after previous AF ablation were studied. RESULTS: At the beginning of the procedure, 140 patients (36.8%) presented in sinus rhythm (SR), 208 (54.7%) with AT and 32 (8.4%) with AF. Patients in SR or with AT underwent shorter procedures (173 (132-213) minutes vs. 161 (120-203) minutes vs. 226 (154-249) minutes; p = 0.002) with more frequent termination to SR (87.9% vs. 81.3% vs. 56.3%; p < 0.001) than patients with AF. Acute procedural success did not differ between patients in SR or with AT but was higher compared to those with AF (96.4% vs. 97.1% vs. 87.5%; p = 0.033). During a follow-up of 290 (181-680) days, patients in baseline SR experienced arrhythmia recurrences less often (36.4% vs. 49.5% vs. 68.8%; p = 0.002) than patients with AT or AF. CONCLUSION: Baseline rhythm during AT ablation predicts procedural and clinical outcome. Whereas acute procedural success does not differ between patients in SR or with AT, patients presenting in SR have a more favorable mid-term success rate.

3.
Sci Rep ; 13(1): 12182, 2023 07 27.
Article in English | MEDLINE | ID: mdl-37500680

ABSTRACT

History of syncope is an independent predictor for sudden cardiac death. Programmed stimulation may be considered for risk stratification, but data remain sparse among different populations. Here, we analyzed the prognostic value of inducible ventricular arrhythmia (VA) regarding clinical outcome in patients with syncope undergoing defibrillator implantation. Among 4196 patients enrolled in the prospective, multi-center German Device Registry, patients with syncope and inducible VA (n = 285, 6.8%) vs. those with a secondary preventive indication (n = 1885, 45.2%), defined as previously documented sustained ventricular tachycardia or ventricular fibrillation, serving as a control group were studied regarding demographics, device implantation and post-procedural adverse events. Patients with syncope and inducible VA (64.9 ± 14.4 years, 81.1% male) presented less frequently with congestive heart failure (15.1% vs. 29.1%; p < 0.001) and any structural heart disease (84.9% vs. 89.3%; p = 0.030) than patients with a secondary preventive indication (65.0 ± 13.8 years, 81.0% male). Whereas dilated cardiomyopathy (16.8% vs. 23.8%; p = 0.009) was less common, hypertrophic cardiomyopathy (5.6% vs. 2.8%; p = 0.010) and Brugada syndrome (2.1% vs. 0.3%; p < 0.001) were present more often. During 1-year-follow-up, mortality (5.1% vs. 8.9%; p = 0.036) and the rate of major adverse cardiac or cerebrovascular events (5.8% vs. 10.0%; p = 0.027) were lower in patients with syncope and inducible VA. Among patients with inducible VA, post-procedural adverse events including rehospitalization (27.6% vs. 21.7%; p = 0.37) did not differ between those with vs. without syncope. Taken together, patients with syncope and inducible VA have better clinical outcomes than patients with a secondary preventive defibrillator indication, but comparable outcomes to patients without syncope, which underlines the relevance of VA inducibility, potentially irrespective of a syncope.


Subject(s)
Defibrillators, Implantable , Tachycardia, Ventricular , Humans , Male , Female , Prospective Studies , Arrhythmias, Cardiac/complications , Arrhythmias, Cardiac/therapy , Tachycardia, Ventricular/complications , Tachycardia, Ventricular/therapy , Ventricular Fibrillation , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Syncope/complications , Registries , Defibrillators , Defibrillators, Implantable/adverse effects , Follow-Up Studies
4.
Front Physiol ; 13: 1001719, 2022.
Article in English | MEDLINE | ID: mdl-36311229

ABSTRACT

Background: Optimal lesion formation during catheter-based radiofrequency current (RFC) ablation depends on electro-mechanical tip-tissue coupling measurable via contact force (CF) and local impedance (LI) monitoring. We aimed to investigate CF and LI dynamics in patients with previous atrial fibrillation (AF) ablation who frequently present with heterogenous arrhythmia substrate. Methods: Data from consecutive patients presenting for repeat AF or atrial tachycardia ablation using a novel open-irrigated single-tip ablation catheter were studied. RFC applications were investigated regarding CF, LI and the maximum LI drop (∆LI) for evaluation of ablation efficacy. ∆LI > 20 Ω was defined as a successful RFC application. Results: A total of 730 RFC applications in 20 patients were analyzed. Baseline CF was not associated with baseline LI (R = 0.06, p = 0.17). A mean CF < 8 g during ablation resulted in lower ∆LI (<8 g: 13 Ω vs. ≥ 8 g: 16 Ω, p < 0.001). Baseline LI showed a better correlation with ∆LI (R = 0.35, p < 0.001) compared to mean CF (R = 0.17, p < 0.001). Mean CF correlated better with ∆LI in regions of low (R = 0.31, p < 0.001) compared to high (R = 0.21, p = 0.02) and intermediate voltage (R = 0.17, p = 0.004). Combined CF and baseline LI predicted ∆LI > 20 Ω (area under the receiver operating characteristic curve (AUC) 0.75) better compared to baseline LI (AUC 0.72), mean CF (AUC 0.60), force-time integral (AUC 0.59) and local bipolar voltage (0.55). Conclusion: Combination of CF and LI may aid monitoring real-time catheter-tissue electro-mechanical coupling and lesion formation within heterogenous atrial arrhythmia substrate in patients with repeat AF or atrial tachycardia ablation.

5.
Auton Neurosci ; 241: 103009, 2022 09.
Article in English | MEDLINE | ID: mdl-35753247

ABSTRACT

BACKGROUND: The importance of peripheral chemoreceptors for cardiorespiratory neural control is known for decades. Pure oxygen inhalation deactivates chemoreceptors and increases parasympathetic outflow. However, the relationship between autonomic nervous system (ANS) activation and resulting respiratory as well as heart rate (HR) dynamics is still not fully understood. METHODS: In young adults the impact of (1) 100 % pure oxygen inhalation (hyperoxic cardiac chemoreflex sensitivity (CHRS) testing), (2) the cold face test (CFT) and (3) the cold pressor test (CPT) on heart rate variability (HRV), hemodynamics and respiratory rate was investigated in randomized order. Baseline ANS outflow was determined assessing respiratory sinus arrhythmia via deep breathing, baroreflex sensitivity and HRV. RESULTS: Baseline ANS outflow was normal in all participants (23 ± 1 years, 7 females, 3 males). Hyperoxic CHRS testing decreased HR (after 60 ± 3 vs before 63 ± 3 min-1, p = 0.004), while increasing total peripheral resistance (1053 ± 87 vs 988 ± 76 dyne*s + m2/cm5, p = 0.02) and mean arterial blood pressure (93 ± 4 vs 91 ± 4 mm Hg, p = 0.02). HRV indicated increased parasympathetic outflow after hyperoxic CHRS testing accompanied by a decrease in respiratory rate (15 ± 1vs 19 ± 1 min-1, p = 0.001). In contrast, neither CFT nor CPT altered the respiratory rate (18 ± 1 vs 18 ± 2 min-1, p = 0.38 and 18 ± 1 vs 18 ± 1 min-1, p = 0.84, respectively). CONCLUSION: Changes in HR characteristics during deactivation of peripheral chemoreceptors but not during the CFT and CPT are related with a decrease in respiratory rate. This highlights the need of respiratory rate assessment when evaluating adaptations of cardiorespiratory chemoreceptor control.


Subject(s)
Respiratory Rate , Sympathetic Nervous System , Blood Pressure/physiology , Chemoreceptor Cells/physiology , Female , Heart Rate/physiology , Humans , Male , Oxygen , Young Adult
7.
Europace ; 24(6): 959-969, 2022 07 15.
Article in English | MEDLINE | ID: mdl-34922350

ABSTRACT

AIMS: Bipolar radiofrequency ablation (B-RFA) has been reported as a bail-out strategy for the treatment of therapy refractory ventricular arrhythmias (VA). Currently, existing setups have not been standardized for B-RFA, while the impact of conventional B-RFA approaches on lesion formation remains unclear. METHODS AND RESULTS: (i) In a multicentre observational study, patients undergoing B-RFA for previously therapy-refractory VA using a dedicated B-RFA setup were retrospectively analysed. (ii) Additionally, in an ex vivo model lesion formation during B-RFA was evaluated using porcine hearts. In a total of 26 procedures (24 patients), acute success was achieved in all 14 ventricular tachycardia (VT) procedures and 7/12 procedures with premature ventricular contractions (PVC), with major complications occurring in 1 procedure (atrioventricular block). During a median follow-up of 211 days in 21 patients, 6/11 patients (VT) and 5/10 patients (PVC) remained arrhythmia-free. Lesion formation in the ex vivo model during energy titration from 30 to 50 W led to similar lesion volumes compared with initial high-power 50 W B-RFA. Lesion size significantly increased when combining sequential unipolar and B-RFA (1429 mm3 vs. titration 501 mm3 vs. B-RFA 50 W 423 mm3, P < 0.001), an approach used in overall 58% of procedures and more frequently applied in procedures without VA recurrence (92% vs. 36%, P = 0.009). Adipose tissue severely limited lesion formation during B-RFA. CONCLUSION: Using a dedicated device for B-RFA for therapy-refractory VA appears feasible and safe. While some patients need repeat ablation, success rates were encouraging. Sequential unipolar and B-RFA may be favourable for lesion formation.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Ventricular Premature Complexes , Animals , Catheter Ablation/methods , Retrospective Studies , Swine , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/surgery , Treatment Outcome , Ventricular Premature Complexes/diagnosis , Ventricular Premature Complexes/surgery
8.
Europace ; 24(4): 538-551, 2022 04 05.
Article in English | MEDLINE | ID: mdl-34967892

ABSTRACT

Worldwide, ∼4 million people die from sudden cardiac death every year caused in more than half of the cases by ischaemic cardiomyopathy (ICM). Prevention of sudden cardiac death after myocardial infarction by implantation of a cardioverter-defibrillator (ICD) is the most common, even though not curative, therapy to date. Optimized ICD programming should be strived for in order to decrease the incidence of ICD interventions. Catheter ablation reduces the recurrence of ventricular tachycardias (VTs) and is an important adjunct to sole ICD-based treatment or pharmacological antiarrhythmic therapy in patients with ICM, as conclusively demonstrated by seven randomized controlled trials (RCTs) in the last two decades. However, none of the conducted trials was powered to reveal a survival benefit for ablated patients as compared to controls. Whereas thorough consideration of an early approach is necessary following two recent RCTs (PAUSE-SCD, BERLIN VT), catheter ablation is particularly recommended in patients with recurrent VT after ICD therapy. In this context, novel, pathophysiologically driven ablation strategies referring to deep morphological and functional substrate phenotyping based on high-resolution mapping and three-dimensional visualization of scars appear promising. Emerging concepts like sympathetic cardiac denervation as well as radioablation might expand the therapeutical armamentarium especially in patients with therapy-refractory VT. Randomized controlled trials are warranted and on the way to investigate how these translate into improved patient outcome. This review summarizes therapeutic strategies currently available for the prevention of VT recurrences, the optimal timing of applicability, and highlights future perspectives after a PAUSE in BERLIN.


Subject(s)
Cardiomyopathies , Catheter Ablation , Defibrillators, Implantable , Tachycardia, Ventricular , Arrhythmias, Cardiac/therapy , Cardiomyopathies/surgery , Cardiomyopathies/therapy , Catheter Ablation/adverse effects , Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects , Humans , Tachycardia, Ventricular/diagnosis , Tachycardia, Ventricular/etiology , Tachycardia, Ventricular/prevention & control , Treatment Outcome
9.
PLoS One ; 16(7): e0254683, 2021.
Article in English | MEDLINE | ID: mdl-34260658

ABSTRACT

BACKGROUND: Myocardial slow conduction is a cornerstone of ventricular tachycardia (VT). Prolonged electrogram (EGM) duration is a useful surrogate parameter and manual annotation of EGM characteristics are widely used during catheter-based ablation of the arrhythmogenic substrate. However, this remains time-consuming and prone to inter-operator variability. We aimed to develop an algorithm for 3-D visualization of EGM duration relative to the 17-segment American Heart Association model. METHODS: To calculate and visualize EGM duration, in sinus rhythm acquired high-density maps of patients with ischemic cardiomyopathy undergoing substrate-based VT ablation using a 64-mini polar basket-catheter with low noise of 0.01 mV were analyzed. Using a custom developed algorithm based on standard deviation and threshold, the relationship between EGM duration, endocardial voltage and ablation areas was studied by creating 17-segment 3-D models and 2-D polar plots. RESULTS: 140,508 EGMs from 272 segments (n = 16 patients, 94% male, age: 66±2.4, ejection fraction: 31±2%) were studied and 3-D visualization of EGM duration was performed. Analysis of signal processing parameters revealed that a 40 ms sliding SD-window, 15% SD-threshold and >70 ms EGM duration cutoff was chosen based on diagnostic odds ratio of 12.77 to visualize rapidly prolonged EGM durations. EGMs > 70 ms matched to 99% of areas within dense scar (<0.2 mV), in 95% of zones within scar border zone (0.2-1.0 mV) and detected ablated areas having resulted in non-inducibility at the end of the procedure. Ablation targets were identified with a sensitivity of 65.6% and a specificity of 94.6% avoiding false positive labeling of prolonged EGMs in segments with healthy myocardium. CONCLUSION: The novel algorithm allows rapid visualization of prolonged EGM durations. This may facilitate more objective characterization of arrhythmogenic substrate in patients with ischemic cardiomyopathy.


Subject(s)
Algorithms , Tachycardia, Ventricular , Aged , Electrophysiologic Techniques, Cardiac , Heart Rate , Humans , Middle Aged
10.
J Am Heart Assoc ; 10(13): e020835, 2021 07 06.
Article in English | MEDLINE | ID: mdl-34121415

ABSTRACT

Background Ultra-high-density mapping enables detailed mechanistic analysis of atrial reentrant tachycardia but has yet to be used to assess circuit conduction velocity (CV) patterns in adults with congenital heart disease. Methods and Results Circuit pathways and central isthmus CVs were calculated from consecutive ultra-high-density isochronal maps at 2 tertiary centers over a 3-year period. Circuits using anatomic versus surgical obstacles were considered separately and pathway length <50th percentile identified small circuits. CV analysis was used to derive a novel index for prediction of postablation conduction block. A total of 136 supraventricular tachycardias were studied (60% intra-atrial reentrant, 14% multiple loop). Circuits with anatomic versus surgical obstacles featured longer pathway length (119 mm; interquartile range [IQR], 80-150 versus 78 mm; IQR, 63-95; P<0.001), faster central isthmus CV (0.1 m/s; IQR, 0.06-0.25 versus 0.07 m/s; IQR, 0.05-0.10; P=0.016), faster non-isthmus CV (0.52 m/s; IQR, 0.33-0.71 versus 0.38 m/s; IQR, 0.27-0.46; P=0.009), and fewer slow isochrones (4; IQR, 2.3-6.8 versus 6; IQR 5-7; P=0.008). Both central isthmus (R2=0.45; P<0.001) and non-isthmus CV (R2=0.71; P<0.001) correlated with pathway length, whereas central isthmus CV <0.15 m/s was ubiquitous for small circuits. Non-isthmus CV in tachycardia correlated with CV during block validation (R2=0.94; P<0.001) and a validation map to tachycardia conduction time ratio >85% predicted isthmus block in all cases. Over >1 year of follow-up, arrhythmia-free survival was better for homogeneous CV patterns (90% versus 57%; P=0.04). Conclusions Ultra-high-density mapping-guided CV analysis distinguishes atrial reentrant patterns in adults with congenital heart disease with surgical obstacles producing slower and smaller circuits. Very slow central isthmus CV may be essential for atrial tachycardia maintenance in small circuits, and non-isthmus conduction time in tachycardia appears to be useful for rapid assessment of postablation conduction block.


Subject(s)
Cardiac Surgical Procedures , Electrophysiologic Techniques, Cardiac , Heart Defects, Congenital/surgery , Tachycardia, Supraventricular/diagnosis , Action Potentials , Adult , Cardiac Surgical Procedures/adverse effects , Catheter Ablation , Female , Germany , Heart Defects, Congenital/complications , Heart Defects, Congenital/diagnosis , Heart Defects, Congenital/physiopathology , Heart Rate , Humans , Los Angeles , Male , Middle Aged , Predictive Value of Tests , Retrospective Studies , Tachycardia, Supraventricular/etiology , Tachycardia, Supraventricular/physiopathology , Tachycardia, Supraventricular/surgery
12.
Arch Med Sci ; 16(5): 1022-1030, 2020.
Article in English | MEDLINE | ID: mdl-32863990

ABSTRACT

INTRODUCTION: Respiratory sinus arrhythmia (RSA) describes heart rate (HR) changes in synchrony with respiration. It is relevant for exercise capacity and mechanistically linked with the cardiac autonomic nervous system. After pulmonary vein isolation (PVI), the current therapy of choice for patients with paroxysmal atrial fibrillation (AF), the cardiac vagal tone is often diminished. We hypothesized that RSA is modulated by PVI in patients with paroxysmal AF. MATERIAL AND METHODS: Respiratory sinus arrhythmia, measured by using a deep breathing test and heart rate variability parameters, was studied in 10 patients (64 ±3 years) with paroxysmal AF presenting in stable sinus rhythm for their first catheter-based PVI. Additionally, heart rate dynamics before and after PVI were studied during sympathetic/parasympathetic coactivation by using a cold-face test. All tests were performed within 24 h before and 48 h after PVI. RESULTS: After PVI RSA (E/I difference: 7.9 ±1.0 vs. 3.5 ±0.6 bpm, p = 0.006; E/I ratio: 1.14 ±0.02 vs. 1.05 ±0.01, p = 0.003), heart rate variability (SDNN: 31 ±3 vs. 14 ±3 ms, p = 0.006; RMSSD: 17 ±2 vs. 8 ±2 ms, p = 0.002) and the HR response to sympathetic/parasympathetic coactivation (10.2 ±0.7% vs. 5.7 ±1.1%, p = 0.014) were diminished. The PVI-related changes in RSA correlated with the heart rate change during sympathetic/parasympathetic coactivation before vs. after PVI (E/I difference: r = 0.849, p = 0.002; E/I ratio: r = 0.786, p = 0.007). One patient with vagal driven arrhythmia experienced AF recurrence during follow-up (mean: 6.5 ±0.6 months). CONCLUSIONS: Respiratory sinus arrhythmia is reduced after PVI in patients with paroxysmal AF. Our findings suggest that this is related to a decrease in cardiac vagal tone. Whether and how this affects the clinical outcome including exercise capacity need to be determined.

13.
Future Cardiol ; 16(6): 735-751, 2020 11.
Article in English | MEDLINE | ID: mdl-32608246

ABSTRACT

Aim: Ultra-high-density mapping (HDM) is increasingly used for guidance of catheter ablation in cardiac arrhythmias. While initial results are promising, a systematic evaluation of long-term outcome has not been performed so far. Methods: A systematic review and meta-analysis was conducted on studies investigating long-term outcome after Rhythmia HDM-guided atrial fibrillation (AF) or atrial tachycardia catheter ablation. Results: Beyond multiple studies providing novel insights into arrhythmia mechanisms, follow-up data from 17 studies analyzing Rhythmia HDM-guided ablation (1768 patients, 49% with previous ablation) were investigated. Cumulative acute success was 100/90.2%, while 12 months long-term pooled success displayed at 71.6/71.2% (AF/atrial tachycardia). Prospective data are limited, showing similar outcome between HDM-guided and conventional AF ablation. Conclusion: Acute results of HDM-guided catheter ablation are promising, while long-term success is challenged by complex arrhythmogenic substrates. Prospective randomized trials investigating different HDM-guided ablation strategies are warranted and underway.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Atrial Fibrillation/surgery , Catheters , Humans , Prospective Studies , Recurrence , Treatment Outcome
14.
Cardiovasc Diagn Ther ; 9(Suppl 2): S247-S263, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31737533

ABSTRACT

BACKGROUND: Ultra-high density mapping (HDM) is a promising tool in the treatment of patients with complex arrhythmias. In adults with congenital heart disease (CHD), rhythm disorders are among the most common complications but catheter ablation can be challenging due to heterogenous anatomy and complex arrhythmogenic substrates. Here, we describe our initial experience using HDM in conjunction with novel automated annotation algorithms in patients with moderate to great CHD complexity. METHODS: We studied a series of consecutive adult patients with moderate to great CHD complexity and an indication for catheter ablation due to symptomatic arrhythmia. HDM was conducted using the Rhythmia™ mapping system and a 64-electrode mini-basket catheter for identification of anatomy, voltage, activation pattern and critical areas of arrhythmia for ablation guidance. To investigate novel advanced mapping strategies, postprocedural signal processing using the Lumipoint™ software was applied. RESULTS: In 19 patients (53±3 years; 53% male), 21 consecutive ablation procedures were conducted. Procedures included ablation of atrial fibrillation (n=7; 33%), atrial tachycardia (n=11; 52%), atrioventricular accessory pathway (n=1; 5%), the atrioventricular node (n=1; 5%) and ventricular arrhythmias (n=4; 19%). A total of 23 supraventricular and 8 ventricular arrhythmias were studied with the generation of 56 complete high density maps (atrial n=43; ventricular n=11, coronary sinus n=2) and an average of 12,043±1,679 mapping points. Multiple arrhythmias were observed in n=7 procedures (33% of procedures; range of arrhythmias detected 2-4). A total range of 1-4 critical areas were defined per procedure and treated within a radiofrequency application time of 16 (interquartile range 12-45) minutes. Postprocedural signal processing using Lumipoint™ allowed rapid annotation of fractionated signals within specific windows of interest. This supported identification of a practical critical isthmus in 20 out of 27 completed atrial and ventricular tachycardia activation maps. CONCLUSIONS: Our findings suggest that HDM in conjunction with novel automated annotation algorithms provides detailed insights into arrhythmia mechanisms and might facilitate tailored catheter ablation in patients with moderate to great CHD complexity.

SELECTION OF CITATIONS
SEARCH DETAIL
...