Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 100
Filter
1.
J Am Heart Assoc ; 13(8): e032033, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38591264

ABSTRACT

BACKGROUND: Chronic total coronary occlusions (CTO) substantially increase the risk for sudden cardiac death. Among patients with chronic ischemic heart disease at risk for sudden cardiac death, an implantable cardioverter defibrillator (ICD) is the favored therapy for primary prevention of sudden cardiac death. This study sought to investigate the impact of CTOs on the risk for appropriate ICD shocks and mortality within a nationwide prospective cohort. METHODS AND RESULTS: This is a subanalysis of the nationwide Dutch-Outcome in ICD Therapy (DO-IT) registry of primary prevention ICD recipients in The Netherlands between September 2014 and June 2016 (n=1442). We identified patients with chronic ischemic heart disease (n=663) and assessed available coronary angiograms for CTO presence (n=415). Patients with revascularized CTOs were excluded (n=79). The primary end point was the composite of all-cause mortality and appropriate ICD shocks. Clinical follow-up was conducted for at least 2 years. A total of 336 patients were included, with an average age of 67±9 years, and 20.5% was female (n=69). An unrevascularized CTO was identified in 110 patients (32.7%). During a median follow-up period of 27 months (interquartile range, 24-32), the primary end point occurred in 21.1% of patients with CTO (n=23) compared with 11.9% in patients without CTO (n=27; P=0.034). Corrected for baseline characteristics including left ventricular ejection fraction, and the presence of a CTO was an independent predictor for the primary end point (hazard ratio, 1.82 [95% CI, 1.03-3.22]; P=0.038). CONCLUSIONS: Within this nationwide prospective registry of primary prevention ICD recipients, the presence of an unrevascularized CTO was an independent predictor for the composite outcome of all-cause mortality and appropriate ICD shocks.


Subject(s)
Coronary Occlusion , Defibrillators, Implantable , Humans , Female , Middle Aged , Aged , Coronary Occlusion/complications , Coronary Occlusion/diagnostic imaging , Coronary Occlusion/therapy , Arrhythmias, Cardiac , Defibrillators, Implantable/adverse effects , Stroke Volume , Incidence , Ventricular Function, Left , Death, Sudden, Cardiac/epidemiology , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Registries , Risk Factors
2.
Radiol Cardiothorac Imaging ; 6(2): e230172, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38573128

ABSTRACT

Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.


Subject(s)
Atrial Fibrillation , Diaphragm , Aged , Humans , Male , Middle Aged , Atrial Fibrillation/diagnosis , Contrast Media , Gadolinium , Heart Atria/diagnostic imaging , Magnetic Resonance Imaging , Prospective Studies , Female
3.
Neth Heart J ; 32(5): 190-197, 2024 May.
Article in English | MEDLINE | ID: mdl-38634993

ABSTRACT

International guidelines recommend implantation of an implantable cardioverter-defibrillator (ICD) in non-ischaemic cardiomyopathy (NICM) patients with a left ventricular ejection fraction (LVEF) below 35% despite optimal medical therapy and a life expectancy of more than 1 year with good functional status. We propose refinement of these recommendations in patients with NICM, with careful consideration of additional risk parameters for both arrhythmic and non-arrhythmic death. These additional parameters include late gadolinium enhancement on cardiac magnetic resonance imaging and genetic testing for high-risk genetic variants to further assess arrhythmic risk, and age, comorbidities and sex for assessment of non-arrhythmic mortality risk. Moreover, several risk modifiers should be taken into account, such as concomitant arrhythmias that may affect LVEF (atrial fibrillation, premature ventricular beats) and resynchronisation therapy. Even though currently no valid cut-off values have been established, the proposed approach provides a more careful consideration of risks that may result in withholding ICD implantation in patients with low arrhythmic risk and substantial non-arrhythmic mortality risk.

5.
Int J Cardiol Heart Vasc ; 50: 101323, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38188347

ABSTRACT

Background: A chronic total coronary occlusion (CTO) is associated with ventricular arrhythmias (VA) in patients with an implantable cardioverter-defibrillator (ICD). Limited data is available on the incidence of VA in CTO patients without an ICD. Objectives: To investigate the incidence of sustained VA in CTO patients after successful CTO revascularization and in patients with untreated CTO or failed CTO revascularization. Methods: Prospective, multicenter observational pilot study including CTO patients who were not eligible for an ICD and had a left ventricular ejection fraction >35 %. We enrolled patients with a successful CTO revascularization (group A) and patients with untreated CTO or failed CTO revascularization (group B). All patients received an implantable loop recorder with remote monitoring. The primary endpoint was sustained VA. Results: Ninety patients were enrolled (mean age 63 ± 10 years, 83.3 % man, mean LVEF 55 ± 8 %). Group A (n = 45) had a higher prevalence of CTO in the left anterior descending artery in comparison to group B (n = 45) (28.9 % versus 4.4 %, P = 0.002). Other baseline characteristics were similar. During a median follow-up time of 26 months (IQR, 19-35), five patients (5.6 %) had a sustained VA. There was no difference in the incidence of sustained VA between groups (3-year cumulative event rate: 8.8 % (group A) versus 4.5 % (Group B), log-rank P = 0.71). Conclusion: Patients with an CTO, who do not qualify for an ICD, have a substantial risk of sustained VA. In our study the incidence was not different between patients with revascularized and those with untreated CTO.

6.
Pacing Clin Electrophysiol ; 47(1): 121-123, 2024 01.
Article in English | MEDLINE | ID: mdl-38055567

ABSTRACT

Cardiac resynchronization therapy (CRT) is an established treatment for heart failure patients with left ventricular dysfunction and a left bundle branch block. However, its impact on right ventricular (RV) function remains uncertain. This cardiac magnetic resonance imaging study found that CRT did not improve RV volumes and function, and CRT-off during follow-up had an immediate detrimental effect on the RV, which may suggest potential unfavorable RV remodeling with RV pacing during CRT.


Subject(s)
Cardiac Resynchronization Therapy , Heart Failure , Humans , Cardiac Resynchronization Therapy/methods , Bundle-Branch Block/therapy , Heart Ventricles/diagnostic imaging , Treatment Outcome , Heart Failure/therapy , Ventricular Function, Left , Electrocardiography/methods
7.
EBioMedicine ; 99: 104937, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38118401

ABSTRACT

BACKGROUND: Risk stratification for ventricular arrhythmias currently relies on static measurements that fail to adequately capture dynamic interactions between arrhythmic substrate and triggers over time. We trained and internally validated a dynamic machine learning (ML) model and neural network that extracted features from longitudinally collected electrocardiograms (ECG), and used these to predict the risk of malignant ventricular arrhythmias. METHODS: A multicentre study in patients implanted with an implantable cardioverter-defibrillator (ICD) between 2007 and 2021 in two academic hospitals was performed. Variational autoencoders (VAEs), which combine neural networks with variational inference principles, and can learn patterns and structure in data without explicit labelling, were trained to encode the mean ECG waveforms from the limb leads into 16 variables. Supervised dynamic ML models using these latent ECG representations and clinical baseline information were trained to predict malignant ventricular arrhythmias treated by the ICD. Model performance was evaluated on a hold-out set, using time-dependent receiver operating characteristic (ROC) and calibration curves. FINDINGS: 2942 patients (61.7 ± 13.9 years, 25.5% female) were included, with a total of 32,129 ECG recordings during a mean follow-up of 43.9 ± 35.9 months. The mean time-varying area under the ROC curve for the dynamic model was 0.738 ± 0.07, compared to 0.639 ± 0.03 for a static (i.e. baseline-only model). Feature analyses indicated dynamic changes in latent ECG representations, particularly those affecting the T-wave morphology, were of highest importance for model predictions. INTERPRETATION: Dynamic ML models and neural networks effectively leverage routinely collected longitudinal ECG recordings for personalised and updated predictions of malignant ventricular arrhythmias, outperforming static models. FUNDING: This publication is part of the project DEEP RISK ICD (with project number 452019308) of the research programme Rubicon which is (partly) financed by the Dutch Research Council (NWO). This research is partly funded by the Amsterdam Cardiovascular Sciences (personal grant F.V.Y.T).


Subject(s)
Defibrillators, Implantable , Humans , Female , Male , Death, Sudden, Cardiac , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/etiology , Arrhythmias, Cardiac/therapy , Electrocardiography , Neural Networks, Computer
8.
Europace ; 25(9)2023 08 02.
Article in English | MEDLINE | ID: mdl-37712675

ABSTRACT

AIMS: Left ventricular ejection fraction (LVEF) is suboptimal as a sole marker for predicting sudden cardiac death (SCD). Machine learning (ML) provides new opportunities for personalized predictions using complex, multimodal data. This study aimed to determine if risk stratification for implantable cardioverter-defibrillator (ICD) implantation can be improved by ML models that combine clinical variables with 12-lead electrocardiograms (ECG) time-series features. METHODS AND RESULTS: A multicentre study of 1010 patients (64.9 ± 10.8 years, 26.8% female) with ischaemic, dilated, or non-ischaemic cardiomyopathy, and LVEF ≤ 35% implanted with an ICD between 2007 and 2021 for primary prevention of SCD in two academic hospitals was performed. For each patient, a raw 12-lead, 10-s ECG was obtained within 90 days before ICD implantation, and clinical details were collected. Supervised ML models were trained and validated on a development cohort (n = 550) from Hospital A to predict ICD non-arrhythmic mortality at three-year follow-up (i.e. mortality without prior appropriate ICD-therapy). Model performance was evaluated on an external patient cohort from Hospital B (n = 460). At three-year follow-up, 16.0% of patients had died, with 72.8% meeting criteria for non-arrhythmic mortality. Extreme gradient boosting models identified patients with non-arrhythmic mortality with an area under the receiver operating characteristic curve (AUROC) of 0.90 [95% confidence intervals (CI) 0.80-1.00] during internal validation. In the external cohort, the AUROC was 0.79 (95% CI 0.75-0.84). CONCLUSIONS: ML models combining ECG time-series features and clinical variables were able to predict non-arrhythmic mortality within three years after device implantation in a primary prevention population, with robust performance in an independent cohort.


Subject(s)
Defibrillators, Implantable , Humans , Female , Male , Patient Selection , Stroke Volume , Ventricular Function, Left , Machine Learning , Death, Sudden, Cardiac/etiology , Death, Sudden, Cardiac/prevention & control , Primary Prevention
9.
JACC Clin Electrophysiol ; 9(12): 2665-2679, 2023 12.
Article in English | MEDLINE | ID: mdl-37737780

ABSTRACT

Cardiac magnetic resonance (CMR) imaging is a valuable noninvasive tool for evaluating tissue response following catheter ablation of atrial tissue. This review provides an overview of the contemporary CMR strategies to visualize atrial ablation lesions in both the acute and chronic postablation stages, focusing on their strengths and limitations. Moreover, the accuracy of CMR imaging in comparison to atrial lesion histology is discussed. T2-weighted CMR imaging is sensitive to edema and tends to overestimate lesion size in the acute stage after ablation. Noncontrast agent-enhanced T1-weighted CMR imaging has the potential to provide more accurate assessment of lesions in the acute stage but may not be as effective in the chronic stage. Late gadolinium enhancement imaging can be used to detect chronic atrial scarring, which may inform repeat ablation strategies. Moreover, novel imaging strategies are being developed, but their efficacy in characterizing atrial lesions is yet to be determined. Overall, CMR imaging has the potential to provide virtual histology that aids in evaluating the efficacy and safety of catheter ablation and monitoring of postprocedural myocardial changes. However, technical factors, scanning during arrhythmia, and transmurality assessment pose challenges. Therefore, further research is needed to develop CMR strategies to visualize the ablation lesion maturation process more effectively.


Subject(s)
Catheter Ablation , Contrast Media , Humans , Gadolinium , Magnetic Resonance Imaging/methods , Catheter Ablation/adverse effects , Magnetic Resonance Spectroscopy
10.
J Am Heart Assoc ; 12(15): e028014, 2023 08.
Article in English | MEDLINE | ID: mdl-37489727

ABSTRACT

Background Among patients with an implantable cardioverter-defibrillator, a high prevalence of atrial fibrillation (AF) is present. Identification of AF predictors in this patient group is of clinical importance to initiate appropriate preventive therapeutic measures to reduce the risk of AF-related complications. This study assesses whether cardiac magnetic resonance imaging-derived atrial characteristics are associated with AF development in patients with a dual-chamber implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator, as detected by the cardiac implantable electronic device. Methods and Results This single-center retrospective study included 233 patients without documented AF history at the moment of device implantation (dual-chamber implantable cardioverter-defibrillator [63.5%] or cardiac resynchronization therapy defibrillator [36.5%]). All patients underwent cardiac magnetic resonance imaging before device implantation. Cardiac magnetic resonance-derived features of left atrial (LA) remodeling were evaluated in all patients. Detection of AF episodes was based on cardiac implantable electronic device interrogation. During a median follow-up of 6.1 years, a newly diagnosed AF episode was detected in 88 of the 233 (37.8%) patients with an ICD. In these patients, increased LA volumes and impaired LA function (LA emptying fraction and LA strain) were found as compared with patients without AF during follow-up. However, a significant association was only found in patients with dilated cardiomyopathy and not in patients with ischemic cardiomyopathy. Conclusions LA remodeling characteristics were associated with development of AF in patients with dilated cardiomyopathy but not patients with ischemic cardiomyopathy, suggesting different mechanisms of AF development in ischemic cardiomyopathy and dilated cardiomyopathy. Assessment of LA remodeling before device implantation might identify high-risk patients for AF.


Subject(s)
Atrial Fibrillation , Cardiomyopathy, Dilated , Defibrillators, Implantable , Myocardial Ischemia , Humans , Atrial Fibrillation/diagnosis , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Defibrillators, Implantable/adverse effects , Retrospective Studies , Cardiomyopathy, Dilated/etiology , Myocardial Ischemia/etiology , Magnetic Resonance Imaging
11.
Int J Cardiovasc Imaging ; 39(9): 1753-1763, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37515682

ABSTRACT

PURPOSE: Left atrial (LA) sphericity is a novel, geometry-based parameter that has been used to visualize and quantify LA geometrical remodeling in patients with atrial fibrillation (AF). This study examined the association between LA sphericity, and LA longitudinal strain and strain rate measured by feature-tracking in AF patients. METHODS: 128 AF patients who underwent cardiovascular magnetic resonance (CMR) imaging in sinus rhythm prior to their pulmonary vein isolation (PVI) procedure were retrospectively analyzed. LA sphericity was calculated by segmenting the LA (excluding the pulmonary veins and the LA appendage) on a 3D contrast enhanced MR angiogram and comparing the resulting shape with a perfect sphere. LA global reservoir strain, conduit strain, contractile strain and corresponding strain rates were derived from cine images using feature-tracking. For statistical analysis, Pearson correlations, multivariable logistic regression analysis, and Student t-tests were used. RESULTS: Patients with a spherical LA (dichotomized by the median value) had a lower reservoir strain and conduit strain compared to patients with a non-spherical LA (-15.4 ± 4.2% vs. -17.1 ± 3.5%, P = 0.02 and - 8.2 ± 3.0% vs. -9.5 ± 2.6%, P = 0.01, respectively). LA strain rate during early ventricular diastole was also different between both groups (-0.7 ± 0.3s- 1 vs. -0.9 ± 0.3s- 1, P = 0.001). In contrast, no difference was found for LA contractile strain (-7.2 ± 2.6% vs. -7.6 ± 2.2%, P = 0.30). CONCLUSIONS: LA passive strain is significantly impaired in AF patients with a spherical LA, though this relation was not independent from LA volume.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Atrial Remodeling , Catheter Ablation , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Retrospective Studies , Predictive Value of Tests , Heart Atria , Catheter Ablation/methods
12.
Am J Cardiol ; 201: 294-301, 2023 08 15.
Article in English | MEDLINE | ID: mdl-37393732

ABSTRACT

Septal midwall late gadolinium enhancement (LGE) is a characteristic finding on cardiac magnetic resonance imaging (CMR) in nonischemic dilated cardiomyopathy (DCM) and is associated with adverse events. Its significance in ischemic cardiomyopathy (ICM) is unknown. With this multicenter observational study, we aimed to study the characteristics of septal midwall LGE and evaluate its prognostic value in ICM. A total of 1,084 patients with an impaired left ventricular (LV) ejection fraction (<50%) on LGE-CMR, either because of ICM (53%) or DCM, were included retrospectively. Septal midwall LGE was defined as midmyocardial stripe-like or patchy LGE in septal segments and was present in 10% of patients with ICM compared with 34% of patients with DCM (p <0.001). It was significantly associated with larger LV volumes and lower LV ejection fraction, irrespective of etiology. The primary endpoint was all-cause mortality and secondary endpoint was ventricular arrhythmias (VAs), including resuscitated cardiac arrest, sustained VA, and appropriate implantable cardioverter-defibrillator (ICD) therapy. During a median follow-up of 2.7 years, we found a significant association between septal midwall LGE and mortality in patients with DCM (hazard ratio [HR] 1.92, p = 0.03), but not in patients with ICM (HR 1.35, p = 0.39). Risk of VAs was significantly higher in patients with septal midwall LGE on CMR, both in DCM (HR 2.80, p <0.01) and in ICM (HR 2.70, p <0.01). In conclusion, septal midwall LGE, typically seen in DCM, was also present in 10% of patients with ICM and was associated with increased LV dilation and worse function, irrespective of etiology. When present, septal midwall LGE was associated with adverse outcome.


Subject(s)
Cardiomyopathy, Dilated , Myocardial Ischemia , Humans , Cardiomyopathy, Dilated/complications , Contrast Media/pharmacology , Gadolinium , Retrospective Studies , Magnetic Resonance Imaging, Cine/methods , Myocardial Ischemia/diagnosis , Myocardial Ischemia/diagnostic imaging , Arrhythmias, Cardiac , Prognosis , Predictive Value of Tests
13.
J Clin Med ; 12(12)2023 Jun 12.
Article in English | MEDLINE | ID: mdl-37373691

ABSTRACT

OBJECTIVES: This prospective pilot study assessed the feasibility of cardiovascular magnetic resonance (CMR) imaging during biventricular (BIV) pacing in patients with a CMR conditional cardiac resynchronization therapy defibrillator (CRT-D) and compared the results with invasive volume measurements. METHODS: Ten CRT-D patients underwent CMR imaging prior to device implantation (baseline) and six weeks after device implantation, including CRT-on and CRT-off modes. Left ventricular (LV) function, volumes, and strain measurements of LV dyssynchrony and dyscoordination were assessed. Invasive pressure-volume measurements were performed, matching the CRT settings used during CMR. RESULTS: Post-implantation imaging enabled reliable cine assessment, but showed artefacts on late gadolinium enhancement images. After six weeks of CRT, significant reverse remodeling was observed, with a 22.7 ± 11% reduction in LV end-systolic volume during intrinsic rhythm (CRT-off). During CRT-on, the LV ejection fraction significantly improved from 27.4 ± 5.9% to 32.2 ± 8.7% (p < 0.01), and the strain assessment showed the abolition of the left bundle branch block contraction pattern. Invasively measured and CMR-assessed LV hemodynamics during BIV pacing were significantly associated. CONCLUSIONS: Post-CRT implantation CMR assessing acute LV pump function is feasible and provides important insights into the effects of BIV pacing on cardiac function and contraction patterns. LV assessment during CMR may constitute a future CRT optimization strategy.

14.
J Med Internet Res ; 25: e44642, 2023 05 26.
Article in English | MEDLINE | ID: mdl-37234033

ABSTRACT

BACKGROUND: Silent paroxysmal atrial fibrillation (AF) may be difficult to diagnose, and AF burden is hard to establish. In contrast to conventional diagnostic devices, photoplethysmography (PPG)-driven smartwatches or wristbands allow for long-term continuous heart rhythm assessment. However, most smartwatches lack an integrated PPG-AF algorithm. Adding a standalone PPG-AF algorithm to these wrist devices might open new possibilities for AF screening and burden assessment. OBJECTIVE: The aim of this study was to assess the accuracy of a well-known standalone PPG-AF detection algorithm added to a popular wristband and smartwatch, with regard to discriminating AF and sinus rhythm, in a group of patients with AF before and after cardioversion (CV). METHODS: Consecutive consenting patients with AF admitted for CV in a large academic hospital in Amsterdam, the Netherlands, were asked to wear a Biostrap wristband or Fitbit Ionic smartwatch with Fibricheck algorithm add-on surrounding the procedure. A set of 1-min PPG measurements and 12-lead reference electrocardiograms was obtained before and after CV. Rhythm assessment by the PPG device-software combination was compared with the 12-lead electrocardiogram. RESULTS: A total of 78 patients were included in the Biostrap-Fibricheck cohort (156 measurement sets) and 73 patients in the Fitbit-Fibricheck cohort (143 measurement sets). Of the measurement sets, 19/156 (12%) and 7/143 (5%), respectively, were not classifiable by the PPG algorithm due to bad quality. The diagnostic performance in terms of sensitivity, specificity, positive predictive value, negative predictive value, and accuracy was 98%, 96%, 96%, 99%, 97%, and 97%, 100%, 100%, 97%, and 99%, respectively, at an AF prevalence of ~50%. CONCLUSIONS: This study demonstrates that the addition of a well-known standalone PPG-AF detection algorithm to a popular PPG smartwatch and wristband without integrated algorithm yields a high accuracy for the detection of AF, with an acceptable unclassifiable rate, in a semicontrolled environment.


Subject(s)
Atrial Fibrillation , Mobile Applications , Humans , Algorithms , Atrial Fibrillation/diagnosis , Electrocardiography/methods , Prospective Studies , Sensitivity and Specificity , Artificial Intelligence , Electric Countershock
17.
Int J Cardiol ; 378: 23-31, 2023 05 01.
Article in English | MEDLINE | ID: mdl-36804765

ABSTRACT

PURPOSE: The present study assesses different left atrial (LA) strain approaches in relation to atrial fibrillation (AF) recurrence after ablation and compares LA feature tracking (FT) strain to novel rapid LA strain approaches in AF patients. METHODS: This retrospective single-center study comprised of 110 prospectively recruited AF patients who underwent cardiac magnetic resonance (CMR) imaging in sinus rhythm prior to their first pulmonary vein isolation ablation. LA rapid strain (long axis strain and atrioventricular (AV)-junction strain), LA FT strain, and LA volumes were derived from 2-chamber and 4-chamber cine images. AF recurrence was followed up for 12 months using either 12­lead ECGs or rhythm Holter monitoring. RESULTS: Arrhythmia recurrence was observed in 39 patients (36%) after the 90-day blanking period, occurring at a median of 181 (122-286) days. LA long axis strain, AV-junction strain, and FT strain were all more impaired in patients with AF recurrence compared to patients without AF recurrence (long axis strain: P < 0.01; AV-junction strain: P < 0.001; FT strain: P < 0.01, respectively). Area under the curve (AUC) values for LA remodeling parameters in association with AF recurrence were 0.68 for long axis strain, 0.68 for AV-junction strain, 0.66 for FT strain, 0.66 for LA volume index. Phasic FT LA strain demonstrated that contractile strain had the highest AUC (0.70). CONCLUSION: Both LA rapid strain and LA FT strain are associated with arrhythmia recurrence after ablation in AF patients. LA rapid strain can be a convenient and reproducible alternative for LA FT strain to assess LA function in clinical practice.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/pathology , Retrospective Studies , Predictive Value of Tests , Heart Atria , Magnetic Resonance Spectroscopy , Catheter Ablation/adverse effects , Catheter Ablation/methods , Recurrence
18.
J Psychosom Res ; 167: 111182, 2023 04.
Article in English | MEDLINE | ID: mdl-36801661

ABSTRACT

OBJECTIVE: Depression and anxiety in patients with an implantable cardioverter-defibrillator (ICD) are associated with adverse outcomes. This study describes the design of the PSYCHE-ICD study and evaluates the correlation between cardiac status and depression and anxiety in ICD patients. METHODS: We included 178 patients. Prior to implantation, patients completed validated psychological questionnaires for depression, anxiety and personality traits. Cardiac status was evaluated by means of left ventricular ejection fraction assessment (LVEF), New York Heart Association (NYHA) functional class, 6-minute walk test (6MWT), and 24-h Holter monitoring for heart rate variability (HRV). A cross-sectional analysis was performed. Follow-up with annual study visits, including repeated full cardiac evaluation, will continue 36 months after ICD implantation. RESULTS: Depressive symptoms were present in 62 (35%) and anxiety in 56 (32%) patients. Values of depression and anxiety significantly increased with higher NYHA class (P < 0.001). Depression symptoms were correlated with a reduced 6MWT (411 ± 128 vs. 488 ± 89, P < 0.001), higher heart rate (74 ± 13 vs. 70 ± 13, P = 0.02), higher thyroid stimulation hormone levels (1.8 [1.3-2.8] vs 1.5 [1.0-2.2], P = 0.03) and multiple HRV parameters. Anxiety symptoms were correlated with higher NYHA class and a reduced 6MWT (433 ± 112 vs 477 ± 102, P = 0.02). CONCLUSION: A substantial part of patients receiving an ICD have symptoms of depression and anxiety at time of ICD implantation. Depression and anxiety were correlated with multiple cardiac parameters, suggesting a possible biological links between psychological distress and cardiac disease in ICD patients.


Subject(s)
Defibrillators, Implantable , Humans , Depression/psychology , Stroke Volume , Cross-Sectional Studies , Ventricular Function, Left , Anxiety/psychology
19.
Eur Heart J Cardiovasc Imaging ; 24(3): 336-345, 2023 02 17.
Article in English | MEDLINE | ID: mdl-35921538

ABSTRACT

AIMS: Bi-atrial remodelling in patients with atrial fibrillation (AF) is rarely assessed and data on the presence of right atrial (RA) fibrosis, the relationship between RA and left atrial (LA) fibrosis, and possible association of RA remodelling with AF recurrence after ablation in patients with AF is limited. METHODS AND RESULTS: A total of 110 patients with AF undergoing initial pulmonary vein isolation (PVI) were included in the present study. All patients were in sinus rhythm during cardiac magnetic resonance (CMR) imaging performed prior to ablation. LA and RA volumes and function (volumetric and feature tracking strain) were derived from cine CMR images. The extent of LA and RA fibrosis was assessed from 3D late gadolinium enhancement images. AF recurrence was followed up for 12 months after PVI using either 12-lead electrocardiograms or Holter monitoring. Arrhythmia recurrence was observed in 39 patients (36%) after the 90-day blanking period, occurring at a median of 181 (interquartile range: 122-286) days. RA remodelling parameters were not significantly different between patients with and without AF recurrence after ablation, whereas LA remodelling parameters were different (volume, emptying fraction, and strain indices). LA fibrosis had a strong correlation with RA fibrosis (r = 0.88, P < 0.001). Both LA and RA fibrosis were not different between patients with and without AF recurrence. CONCLUSIONS: This study shows that RA remodelling parameters were not predictive of AF recurrence after AF ablation. Bi-atrial fibrotic remodelling is present in patients with AF and moreover, the amount of LA fibrosis had a strong correlation with the amount of RA fibrosis.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Humans , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/pathology , Contrast Media , Atrial Function, Right , Gadolinium , Heart Atria , Fibrosis , Catheter Ablation/methods , Recurrence , Treatment Outcome
20.
Heart Rhythm O2 ; 4(12): 777-783, 2023 Dec.
Article in English | MEDLINE | ID: mdl-38204465

ABSTRACT

Background: Invasive measurements of left ventricular (LV) hemodynamic performance can evaluate acute response to cardiac resynchronization therapy (CRT). Objective: The study sought to determine which metric, maximum rate of LV pressure rise (LV dP/dtmax) or LV stroke work (LVSW), is more strongly associated with long-term prognosis. Methods: CRT patients were prospectively included from 3 academic centers. Invasive pressure-volume loop measurements during implantation were performed, and LV dP/dtmax and LVSW were determined at baseline and during biventricular pacing (BVP) as well as their relative increase (%Δ). Hazard ratios (HRs) for the primary outcome of 8-year all-cause mortality were derived using Cox proportional hazards. The secondary endpoint was echocardiographic response, defined as 6-month LV end-systolic volume reduction ≥15%. Results: Paired data from 82 patients were analyzed (67% male; age 66 ± 9 years; QRS duration 158 ± 22 ms, median survival time 72 months). Survival was better when LVSW during BVP was ≥4400 mL∙mm Hg (HR 0.21, 95% CI 0.08-0.58, P < .003) or when ΔLVSW% was ≥10% (HR 0.22, 95% CI 0.08-0.65, P = .006). In multivariate analysis, following direct comparison of continuous measures of acute ΔLV dP/dtmax% and ΔLVSW%, only ΔLVSW% remained associated with the primary endpoint (HR 0.982 per percentage point, P = .028). In contrast to LV dP/dtmax (all P > .05), significant associations with echocardiographic response were found for stroke work during BVP (area under the receiver-operating characteristic curve 0.745, P = .001) and ΔLVSW% (area under the receiver-operating characteristic curve 0.803, P < .001). Conclusion: Stroke work, but not LV dP/dtmax, is consistently associated with long-term prognosis and response after CRT. Our results therefore favor the use of stroke work as the hemodynamic parameter to predict long-term outcome after CRT.

SELECTION OF CITATIONS
SEARCH DETAIL
...