Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Language
Publication year range
1.
Prensa méd. argent ; 107(1): 44-46, 20210000. fig
Article in English | LILACS, BINACIS | ID: biblio-1362189

ABSTRACT

The diagnosis of a hiatus hernia (HH) is typically confirmed with an upper gastrointestinal barium X-ray, gastroscopy or upper-intestinal endoscopy. In several cases, HH has been diagnosed with an echocardiogram. We here describe a case of an HH visible on an echocardiogram in a male patient with chest pain.


Subject(s)
Humans , Male , Middle Aged , Echocardiography , Gastroscopy , Barium Enema , Hernia, Hiatal/diagnosis
2.
Monaldi Arch Chest Dis ; 91(1)2021 Jan 21.
Article in English | MEDLINE | ID: mdl-33478204

ABSTRACT

Due to the proximity of the transvers sinus (TS) to the left atrial appendage (LAA) and pulmonary veins (PV), a mass in the TS can be misinterpreted as a LAA or PV thrombus, and considered as a source of emboli in a patient with stroke or transient ischemic attack. The incorrect identification of a mass as a LAA thrombus would initiate unnecessary anticoagulation therapy or potentially, an evaluation for the excision of the mass if there is a concern about dislodgement. We are presenting a case illustrating this confusion and review the literature for similar cases.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Pulmonary Veins , Thrombosis , Atrial Appendage/diagnostic imaging , Echocardiography, Transesophageal , Humans
3.
Asian Cardiovasc Thorac Ann ; 29(5): 408-410, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33108901

ABSTRACT

Diastolic mitral regurgitation is a unique Doppler finding that can be missed if special attention is not paid to it. There are a few causes of such abnormal flow, ranging from a conduction abnormality to abnormal valvular and left ventricle function. Failure to recognize it might lead to unnecessary investigations and delay the primary diagnosis. We are presenting a teaching case and discuss the associated pathology.


Subject(s)
Mitral Valve Insufficiency , Diastole , Heart Murmurs , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/etiology
4.
Eur J Case Rep Intern Med ; 7(10): 001913, 2020.
Article in English | MEDLINE | ID: mdl-33083370

ABSTRACT

The effect of COVID-19 on the cardiovascular system still needs to be clarified. Patients can develop a spectrum of cardiac diseases, from mild myocarditis to acute coronary syndrome with an impaired systolic fraction. We describe an interesting case of transient ST segment elevation in a COVID-19 patient admitted to ICU for severe respiratory distress syndrome. During his stay in ICU, the patient developed transient ST segment elevation in inferior-lateral leads which promptly resolved without requiring any additional invasive and/or pharmacological treatment. Transthoracic echocardiography showed a preserved ejection fraction without any regional abnormalities and the rise in enzyme biomarkers was insignificant. The case highlights the importance of avoiding invasive procedures in this subset of patients to reduce both patient complications and medical staff exposure. Careful evaluation including echocardiogram and second-line examinations should be performed before invasive and aggressive treatment is undertaken. LEARNING POINTS: Transient ST elevation may occur in critically ill COVID-19 patients.Early recognition is important to avoid unnecessary intervention or thrombolytic therapy.

5.
Eur J Case Rep Intern Med ; 7(6): 001703, 2020.
Article in English | MEDLINE | ID: mdl-32523923

ABSTRACT

BACKGROUND: Very limited information is available on pericardial effusion as a complication of COVID-19 infection. There are no reports regarding pericardial fluid findings in COVID-19 patients. CASE DESCRIPTION: We describe a 41-year-old woman, with confirmed COVID-19, who presented with a large pericardial effusion. The pericardial fluid was drained. We present the laboratory findings to improve knowledge of this virus. DISCUSSION: We believe this is the first such reported case. Findings suggested the fluid was exudative, with remarkably high lactate dehydrogenase and albumin levels. We hope our data provide additional insight into the diagnosis and therapeutic options for managing this infection.LEARNING POINTS: Laboratory findings of drained pericardial fluid in a patient with COVID-19 are presented.The clinical presentation of pericardial involvement in COVID-19 infection and the role of echocardiography in diagnosis and management are described.

6.
J Cardiovasc Echogr ; 30(3): 177-178, 2020.
Article in English | MEDLINE | ID: mdl-33447512

ABSTRACT

We report this case, which described the echocardiographic and chest X-ray appearance of the amplatzer device. The echo images raised suspicion of a mass in the left atrium, but a simple X-ray showed that the mass is an amplatzer device for left atrial appendage closure.

SELECTION OF CITATIONS
SEARCH DETAIL
...