Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Ann Biomed Eng ; 50(4): 467-481, 2022 Apr.
Article in English | MEDLINE | ID: mdl-35212855

ABSTRACT

The current interest of those dealing with medical research is the preparation of digital twins. In this frame, the first step to accomplish is the preparation of reliable numerical models. This is a challenging task since it is not common to know the exact device geometry and material properties unless in studies performed in collaboration with the manufacturer. The particular case of modeling Ni-Ti stents can be highlighted as a worst-case scenario due to both the complex geometrical features and non-linear material response. Indeed, if the limitations in the description of the geometry can be overcome, many difficulties still exist in the assessment of the material, which can vary according to the manufacturing process and requires many parameters for its description. The purpose of this work is to propose a coupled experimental and computational workflow to identify the set of material properties in the case of commercially-resembling Ni-Ti stents. This has been achieved from non-destructive tensile tests on the devices compared with results from Finite Element Analysis (FEA). A surrogate modeling approach is proposed for the identification of the material parameters, based on a minimization problem on the database of responses of Ni-Ti materials obtained with FEA with a series of different parameters. The reliability of the final result was validated through the comparison with the output of additional experiments.


Subject(s)
Nickel , Titanium , Finite Element Analysis , Materials Testing , Reproducibility of Results , Stents
2.
J Biomech Eng ; 140(11)2018 Nov 01.
Article in English | MEDLINE | ID: mdl-30029260

ABSTRACT

Posterior spinal fixation based on long spinal rods is the clinical gold standard for the treatment of severe deformities. Rods need to be contoured prior to implantation to fit the natural curvature of the spine. The contouring processes is known to introduce residual stresses and strains which affect the static and fatigue mechanical response of the implant, as determined through time- and cost-consuming experimental tests. Finite element (FE) models promise to provide an immediate understanding on residual stresses and strains within a contoured spinal rods and a further insight on their complex distribution. This study aims at investigating two rod contouring strategies, French bender (FB) contouring (clinical gold standard), and uniform contouring, through validated FE models. A careful characterization of the elastoplastic material response of commercial implants is led. Compared to uniform contouring, FB induces highly localized plasticizations in compression under the contouring pin with extensive lateral sections undergoing tensile residual stresses. The sensitivity analysis highlighted that the assumed postyielding properties significantly affect the numerical predictions; therefore, an accurate material characterization is recommended.

SELECTION OF CITATIONS
SEARCH DETAIL
...