1.
J Ultrasound ; 21(2): 169, 2018 06.
Article in English | MEDLINE | ID: mdl-29569137

ABSTRACT

Unfortunately, in the first sentence under the section head "Point shear wave elastography", the transducer name was misspelled as CA541 (rather than CA451).

2.
J Ultrasound ; 20(3): 213-225, 2017 Sep.
Article in English | MEDLINE | ID: mdl-28900522

ABSTRACT

PURPOSE: Different shear wave elastography (SWE) machines able to quantify liver stiffness (LS) have been recently introduced by various companies. The aim of this study was to investigate the agreement between point SWE with Esaote MyLab Twice (pSWE.ESA) and 2D SWE with Aixplorer SuperSonic (2D SWE.SSI). Moreover, we assessed the correlation of these machines with Fibroscan in a subgroup of patients. METHODS: A total of 81 liver disease patients and 27 subjects without liver disease accessing the ultrasound lab were considered. Exclusion criteria were liver nodules, BMI >35, and severe comorbidities. LS was sampled from the same intercostal space with both pSWE.ESA and 2D SWE.SSI and values were tested with Lin's analysis and Bland-Altman analysis (B&A). Agreement between each SWE machine and Fibroscan was assessed in 26 liver disease patients with Spearman correlation. RESULTS: Precision and accuracy between pSWE.ESA and 2D SWE.SSI were, respectively, 0.839 and 0.999. B&A showed a mean of only -0.2 kPa, with no systematic deviation between the techniques and limits of agreement at -11.6 and 11.3 kPa. Spearman's rho correlation versus Fibroscan was 0.849 for pSWE.ESA and 0.878 for 2D SWE.SSI. The relationship became less strict in the higher range of LS (≥15.2 kPa), corresponding to cirrhosis. CONCLUSION: The overall degree of concordance of pSWE.ESA and 2D SWE.SSI in measuring LS resulted remarkable, also when compared with Fibroscan. The less strict correlation for patients with LS in the higher range would not affect the staging of disease as such patients are anyhow classified as cirrhotic.


Subject(s)
Elasticity Imaging Techniques/methods , Liver Diseases/diagnostic imaging , Liver Diseases/physiopathology , Liver/diagnostic imaging , Liver/physiopathology , Adult , Aged , Aged, 80 and over , Biomarkers/blood , Body Mass Index , Cross-Sectional Studies , Elasticity , Female , Humans , Liver/physiology , Male , Middle Aged , Regression Analysis , Young Adult
3.
Med Eng Phys ; 37(7): 631-41, 2015 Jul.
Article in English | MEDLINE | ID: mdl-25979670

ABSTRACT

Laser Ablation (LA) is a minimally-invasive procedure for tumor treatment. LA outcomes depend on the heat distribution inside tissues and require accurate temperature measurement during the procedure. Magnetic resonance imaging (MRI) allows a non-invasive and three-dimensional thermometry of the organ undergoing LA. In this study, the temperature distribution within two swine pancreases and three swine livers undergoing LA (Nd:YAG, power: 2 W, treatment time: 4 min) was monitored by a 1.5-T MR scanner, utilizing two T1-weighted sequences (IRTF and SRTF). The signal intensity in four regions of interest, placed at different distances from the laser applicator, was related to temperature variations monitored in the same regions by twelve fiber Bragg grating sensors. The relationship between the signal intensity and temperature increase was calculated to obtain the calibration curve and to evaluate accuracy, sensibility and precision of each sequence. This is the first study of MR-based thermometry during LA on pancreas. More specifically, the IRTF sequence provides the highest temperature sensitivity in both liver (1.8 ± 0.2 °C(-1)) and pancreas (1.8 ± 0.5 °C(-1)) and the lowest precision and accuracy. SRTF sequence on pancreas presents the highest accuracy and precision (MODSFRT = -0.1 °C and LOASFRT = [-2.3; 2.1] °C).


Subject(s)
Laser Therapy/methods , Liver/surgery , Magnetic Resonance Imaging, Interventional/methods , Pancreas/surgery , Thermometry/methods , Animals , Calibration , Laser Therapy/instrumentation , Lasers , Linear Models , Liver/anatomy & histology , Liver/physiology , Magnetic Resonance Imaging/instrumentation , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging, Interventional/instrumentation , Pancreas/anatomy & histology , Pancreas/physiology , Swine , Temperature , Thermometry/instrumentation