J AOAC Int ; 101(5): 1490-1507, 2018 Sep 01.
Article in English | MEDLINE | ID: mdl-29703274

ABSTRACT

The Romer Labs RapidChek® Listeria monocytogenes test system (Performance Tested Method 011805) was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service Microbiology Laboratory Guidebook (USDA-FSIS/MLG), U.S. Food and Drug Association Bacteriological Analytical Manual (FDA/BAM), and AOAC Official Methods of Analysis (AOAC/OMA) cultural reference methods for the detection of L. monocytogenes on selected foods including hot dogs, frozen cooked breaded chicken, frozen cooked shrimp, cured ham, and ice cream, and environmental surfaces including stainless steel and plastic in an unpaired study design. The RapidChek method uses a proprietary enrichment media system, a 44-48 h enrichment at 30 ± 1°C, and detects L. monocytogenes on an immunochromatographic lateral flow device within 10 min. Different L. monocytogenes strains were used to spike each of the matrixes. Samples were confirmed based on the reference method confirmations and an alternate confirmation method. A total of 140 low-level spiked samples were tested by the RapidChek method after enrichment for 44-48 h in parallel with the cultural reference method. There were 88 RapidChek presumptive positives. One of the presumptive positives was not confirmed culturally. Additionally, one of the culturally confirmed samples did not exhibit a presumptive positive. No difference between the alternate confirmation method and reference confirmation method was observed. The respective cultural reference methods (USDA-FSIS/MLG, FDA/BAM, and AOAC/OMA) produced a total of 63 confirmed positive results. Nonspiked samples from all foods were reported as negative for L. monocytogenes by all methods. Probability of detection analysis demonstrated no significant differences in the number of positive samples detected by the RapidChek method and the respective cultural reference method.


Subject(s)
Food Analysis/methods , Immunoassay/methods , Listeria monocytogenes/isolation & purification , Listeriosis/microbiology , Animals , Environmental Monitoring/economics , Environmental Monitoring/methods , Food Microbiology , Humans , Immunoassay/economics , Limit of Detection , Time Factors
2.
J AOAC Int ; 95(3): 850-9, 2012.
Article in English | MEDLINE | ID: mdl-22816277

ABSTRACT

The SDIX RapidChek Listeria F.A.S.T. test system was validated against the U.S. Department of Agriculture-Food Safety and Inspection Service (USDA-FSIS) cultural reference method for the detection of Listeria species on stainless steel, plastic, rubber, and painted concrete. The SDIX method uses a proprietary RapidChek Listeria enrichment media for a one-step, 24-40 h enrichment at 30 degrees C, and detects Listeria on an immunochromatographic lateral flow device in 10 min. Different Listeria species were used to spike each of the environmental surfaces. Environmental surfaces were spiked at levels ranging from 50 to 400 CFU/surface (1 in.2 swabs for painted concrete, 4 in.(2) for sponge). A total of 120 spiked samples were tested by the SDIX method at 24 and 40 h and the cultural reference method. Total confirmed positives were 49, 54, and 48 for the SDIX 24 h method, the SDIX 40 h method, and the USDA-FSIS cultural reference method, respectively. Nonspiked samples from all environmental surfaces were reported as negative for Listeria spp. by all methods. The overall Chi square was 0.017 (P = 0.104) and 0.611 (P= 0.566) after a 24 and 40 h enrichment, respectively, indicating that the test method was equivalent in performance to the reference method at both enrichment times. The SDIX method was evaluated for the detection of 50 Listeria and 35 non-Listeria bacterial strains. All 50 Listeria strains were detected by the method (100% sensitivity). Five out of 35 non-Listeria species gave light test signals when grown in nonselective broth culture and tested undiluted. However, when grown in the RapidChek Listeria F.A.S.T. proprietary media, only one bacterial strain (Staphylococcus aureus) was detected, giving a very low test signal (97% specificity). The method was shown to be robust toward several alterations in testing and storage conditions.


Subject(s)
Bacteriological Techniques/methods , Environmental Microbiology , Listeria/isolation & purification , Reagent Kits, Diagnostic
3.
J AOAC Int ; 94(4): 1138-53, 2011.
Article in English | MEDLINE | ID: mdl-21919348

ABSTRACT

The RapidChek SELECT Salmonella Enteritidis Test System was validated for the detection of Salmonella Enteritidis (SE) in poultry house drag swabs, shell egg pools, and chicken carcass rinsates. The method utilizes RapidChek SELECT Salmonella (AOAC PTM License No. 080601) proprietary primary and secondary enrichment media. Following enrichment, an immunochromatographic test strip is inserted into the tube containing the secondary enrichment broth, developed for 10 min, and interpreted. Salmonella Enteritidis-inoculated samples (1-5 CFU SE/analytical unit) were tested by the test method as well as the appropriate cultural reference method U.S. Food and Drug Administration-Bacteriological Analytical Manual (drag swabs and egg pools) or U.S. Department of Agriculture-Food Safety and Inspection Service (chicken carcass rinsates). A total of 80 samples were tested by both methods in the study. Fifty-two samples were positive by the RapidChek SELECT Salmonella Enteritidis method and 38 were found positive by the respective reference method. The sensitivity of the method was 100% and the specificity was 100%. The accuracy of the test method was 137%, indicating that the method was more sensitive than the reference method. The RapidChek SELECT Salmonella Enteritidis method was tested with 82 Salmonella Group D1 strains including 63 Salmonella Enteritidis strains as well as 32 non-Salmonella Group D1 strains representing 10 bacteria genera. The test method detected all 82 Group D1 strains (100% sensitivity). None of the non-Salmonella Group D1 or other genera of bacteria were detected, indicating a specificity of 100%. The method was shown to be highly robust and stable under control and accelerated stability conditions.


Subject(s)
Chickens/microbiology , Eggs/microbiology , Poultry Diseases/microbiology , Salmonella Infections, Animal/diagnosis , Salmonella enteritidis/isolation & purification , Animals , Culture Media , Housing, Animal , Indicators and Reagents , Poultry Diseases/diagnosis , Reagent Kits, Diagnostic , Reproducibility of Results , Sensitivity and Specificity