Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Analyst ; 146(22): 6780-6787, 2021 Nov 08.
Article in English | MEDLINE | ID: mdl-34636822

ABSTRACT

Three-dimensional (3D) dried blood spheroids form when whole blood is deposited onto hydrophobic paper and allowed to dry in ambient air. The adsorbed 3D dried blood spheroid present at the surface of the hydrophobic paper is observed to offer enhanced stability for labile analytes that would otherwise degrade if stored in the traditional two-dimensional (2D) dried blood spot method. The protective mechanism for the dried blood spheroid microsampling platform was studied using scanning electron microscopy (SEM), which revealed the presence of a passivation thin film at the surface of the spheroid that serves to stabilize the interior of the spheroid against environmental stressors. Through time-course experiments based on sequential SEM analyses, we discovered that the surface protective thin film forms through the self-assembly of red blood cells following the evaporation of water from the blood sample. The bridging mechanism of red blood cell aggregation is evident in our experiments, which leads to the distinct rouleau conformation of stacked red blood cells in less than 60 min after creating the blood spheroid. The stack of self-assembled red blood cells at the exterior of the spheroid subsequently lyse to afford the surface protective layer detected to be approximately 30 µm in thickness after three weeks of storage in ambient air. We applied this mechanistic insight to plasma and serum to enhance stability when stored under ambient conditions. In addition to physical characterization of these thin biofilms, we also used paper spray (PS) mass spectrometry (MS) to examine chemical changes that occur in the stored biofluid. For example, we present stability data for cocaine spiked in whole blood, plasma, and serum when stored under ambient conditions on hydrophilic and hydrophobic paper substrates.


Subject(s)
Cocaine , Dried Blood Spot Testing , Hydrophobic and Hydrophilic Interactions , Mass Spectrometry , Plasma
2.
Langmuir ; 35(43): 13853-13859, 2019 Oct 29.
Article in English | MEDLINE | ID: mdl-31585036

ABSTRACT

We have developed a new spray-based method for characterizing surface energies of planar, porous substrates. Distinct spray modes (electrospray versus electrostatic spray), from the porous substrates, occur in the presence of an applied DC potential after wetting with solvents of different surface tension. The ion current resulting from the spray process is maximized when the surface energy of the porous substrate approaches the surface tension of the wetting solvent. By monitoring the selected ion current (e.g., benzoylecgonine, m/z 290 → 168) with a mass spectrometer or the total ion current with an ammeter, we determined the solvent surface tension yielding the maximum ion current to indicate the surface energy of the solid. Detailed evaluations using polymeric substrates of known surface energies enabled effective calibration of the approach that resulted in the correct estimation of the surface energy of hydrophobic paper substrates prepared by gas-phase silanization. A three-parameter empirical model suggests that the experimentally observed ion current profile is governed by differential partitioning of analyte controlled by the interfacial forces between the wetting solvent and the porous substrate.

3.
Anal Chem ; 90(15): 9353-9358, 2018 08 07.
Article in English | MEDLINE | ID: mdl-29975501

ABSTRACT

It is well-known that 2D dried blood spots on paper offer a facile sample collection, storage, and transportation of blood. However, large volume requirements, possible analyte instability, and difficult sample recovery plague this method, lowering confidence in analyte quantification. For the first time, we demonstrate a new approach using 3D dried blood spheroids for stabilization of small volume blood samples, mitigating these effects without cold storage. Blood spheroids form on hydrophobic paper, preventing interaction between the sample and paper substrate, eliminating all chromatographic effects. Stability of the enzyme alanine transaminase and labile organic compounds such as cocaine and diazepam were also shown to increase in the spheroid by providing a critical radius of insulation. On-surface analysis of the dried blood spheroids using paper spray mass spectrometry resulted in sub-ng/mL limits of detection for all illicit drugs tested, representing 1 order of magnitude improvement compared with analysis from 2D dried blood spots.


Subject(s)
Dried Blood Spot Testing/methods , Temperature , Alanine Transaminase/blood , Cocaine/blood , Diazepam/blood , Enzyme Stability , Humans , Hydrophobic and Hydrophilic Interactions , Limit of Detection
SELECTION OF CITATIONS
SEARCH DETAIL
...