Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
1.
Article in English | MEDLINE | ID: mdl-38735794

ABSTRACT

PURPOSE: The purpose of this study is to identify if the local institutional shift from routine overnight observation to same-day discharge following percutaneous cryoablation (PCA) of renal tumors increases 30 day re-admission rates or serious adverse events (AEs). MATERIALS AND METHODS: This retrospective study included 133 adult patients. PCA patients in calendar years 2018-2019 were routinely observed overnight in the hospital, comprising the control group (Group A). PCA patients in calendar years 2021-2022 were routinely discharged the same day, comprising the test group (Group B). Relevant demographic information, tumor characteristics, technical outcomes, and clinical outcomes were recorded. RESULTS: 15 patients (11.3 %) from the total cohort were re-admitted to the hospital within 30 days of PCA for any reason. Seven patients (10.4 %) and eight patients (12.1 %) were re-admitted for any reason within 30 days in Group A and Group B, respectively, with no difference between the two groups (p = 0.76). Nine patients (6.8 %) from the total cohort were re-admitted to the hospital within 30 days for a diagnosis secondary to the procedure. Four patients (6 %) and five patients (7.6 %) were re-admitted within 30 days for reasons related to PCA in Group A and Group B, respectively, with no significant difference between the groups (p = 0.71). Eight patients (12 %) and four patients (6 %) had major AEs following PCA in Group A and Group B, respectively, with no difference between the two groups (p = 0.43). CONCLUSION: Overall, the change in post-procedural care after PCA did not have a deleterious effect on 30 day re-admission rates or rates of major AEs.

2.
Indoor Air ; 32(1): e12930, 2022 01.
Article in English | MEDLINE | ID: mdl-34519380

ABSTRACT

Reliable methods to detect the presence of SARS-CoV-2 at venues where people gather are essential for epidemiological surveillance to guide public policy. Communal screening of air in a highly crowded space has the potential to provide early warning on the presence and potential transmission of SARS-CoV-2 as suggested by studies early in the epidemic. As hospitals and public facilities apply varying degrees of restrictions and regulations, it is important to provide multiple methodological options to enable environmental SARS-CoV-2 surveillance under different conditions. This study assessed the feasibility of using high-flowrate air samplers combined with RNA extraction kit designed for environmental sample to perform airborne SARS-CoV-2 surveillance in hospital setting, tested by RT-qPCR. The success rate of the air samples in detecting SARS-CoV-2 was then compared with surface swab samples collected in the same proximity. Additionally, positive RT-qPCR samples underwent viral culture to assess the viability of the sampled SARS-CoV-2. The study was performed in inpatient ward environments of a quaternary care university teaching hospital in Singapore housing active COVID-19 patients within the period of February to May 2020. Two types of wards were tested, naturally ventilated open-cohort ward and mechanically ventilated isolation ward. Distances between the site of air sampling and the patient cluster in the investigated wards were also recorded. No successful detection of airborne SARS-CoV-2 was recorded when 50 L/min air samplers were used. Upon increasing the sampling flowrate to 150 L/min, our results showed a high success rate in detecting the presence of SARS-CoV-2 from the air samples (72%) compared to the surface swab samples (9.6%). The positive detection rate of the air samples along with the corresponding viral load could be associated with the distance between sampling site and patient. The furthest distance from patient with PCR-positive air samples was 5.5 m. The airborne SARS-CoV-2 detection was comparable between the two types of wards with 60%-87.5% success rate. High prevalence of the virus was found in toilet areas, both on surfaces and in air. Finally, no successful culture attempt was recorded from the environmental air or surface samples.


Subject(s)
Air Microbiology , Air Pollution, Indoor , Hospitals , SARS-CoV-2/isolation & purification , COVID-19 , Humans , RNA, Viral , Specimen Handling
4.
JAMA Otolaryngol Head Neck Surg ; 147(5): 418-425, 2021 05 01.
Article in English | MEDLINE | ID: mdl-33599684

ABSTRACT

Importance: Three-dimensionally printed nasopharyngeal swabs (3DP swabs) have been used to mitigate swab shortages during the coronavirus disease 2019 (COVID-19) pandemic. Clinical validation for diagnostic accuracy and consistency, as well as patient acceptability, is crucial to evaluate the swab's performance. Objective: To determine the accuracy and acceptability of the 3DP swab for identifying severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Design, Setting, and Participants: A diagnostic study was conducted from May to July 2020 at 2 tertiary care centers in Singapore with different reference swabs (FLOQSwab [COPAN Diagnostics] or Dacron swab [Deltalab]) and swab processing techniques (wet or dry) to evaluate the performance of the 3DP swab compared with traditional, standard-of-care nasopharyngeal swabs used in health care institutions. The participants were patients with COVID-19 in the first 2 weeks of illness and controls with acute respiratory illness with negative test results for SARS-CoV-2. Paired nasopharyngeal swabs were obtained from the same nostril and tested for SARS-CoV-2 by reverse-transcriptase polymerase chain reaction. The sequence of swabs was randomized based on odd and even participant numbers. Main Outcomes and Measures: Primary outcome measures were overall agreement (OA), positive percentage agreement (PPA), and negative percentage agreement of the 3DP swab compared with reference swabs. Secondary outcome measures were the correlation of cycle threshold (Ct) values of both swabs. Results: The mean (SD) age of participants was 45.4 (13.1) years, and most participants were men (87 of 89 [97.8%]), in keeping with the epidemiology of the COVID-19 pandemic in Singapore. A total of 79 patients with COVID-19 and 10 controls were recruited. Among the patients with COVID-19, the overall agreement and PPA of the 3DP swab was 91.1% and 93.5%, respectively, compared with reference swabs. The PPA was 100% for patients with COVID-19 who were tested within the first week of illness. All controls tested negative. The reverse-transcriptase polymerase chain reaction Ct values for the ORF1ab and E-gene targets showed a strong correlation (intraclass correlations coefficient, 0.869-0.920) between the 3DP and reference swab on independent testing at each institution despite differences in sample processing. Discordant results for both gene targets were observed only at high Ct values. Conclusions and Relevance: In this diagnostic study of 79 patients with COVID-19 and 10 controls, the 3DP swab performed accurately and consistently across health care institutions and could help mitigate strained resources in the escalating COVID-19 pandemic.


Subject(s)
COVID-19 Nucleic Acid Testing/instrumentation , COVID-19/diagnosis , Nasopharynx/virology , Printing, Three-Dimensional , Adult , Equipment Design , Humans , Middle Aged , Pandemics , SARS-CoV-2
5.
Infect Dis Ther ; 10(2): 1015-1022, 2021 Jun.
Article in English | MEDLINE | ID: mdl-33432534

ABSTRACT

INTRODUCTION: The gold standard for COVID-19 diagnosis is currently a real-time reverse transcriptase polymerase chain reaction (RT-PCR) to detect SARS-CoV-2. This is most commonly performed on respiratory secretions obtained via a nasopharyngeal swab. Due to supply chain limitations and high demand worldwide because of the COVID-19 pandemic, access to commercial nasopharyngeal swabs has not been assured. 3D printing methods have been used to meet the shortfall. For longer-term considerations, 3D printing may not compare well with injection molding as a production method due to the challenging scalability and greater production costs of 3D printing. METHODS: To secure sufficient nasopharyngeal swab availability for our national healthcare system, we designed a novel injection molded nasopharyngeal swab (the IM2 swab). We performed a clinical diagnostic study comparing the IM2 swab to the Copan FLOQSwab. Forty patients with a known diagnosis of COVID-19 and 10 healthy controls were recruited. Paired nasopharyngeal swabs were obtained from the same nostril of each participant and tested for SARS-CoV-2 by RT-PCR. RESULTS: When compared to the Copan FLOQswab, results from the IM2 swab displayed excellent overall agreement and positive percent agreement of 96.0% and 94.9%, respectively. There was no significant difference in mean RT-PCR cycle threshold values for the ORF1ab (28.05 vs. 28.03, p = 0.97) and E-gene (29.72 vs. 29.37, p = 0.64) targets, respectively. We did not observe any significant adverse events and there was no significant difference in patient-reported pain. CONCLUSION: In summary, the IM2 nasopharyngeal swab is a clinically safe, highly accurate option to commercial nasopharyngeal swabs.

6.
BMC Med ; 18(1): 179, 2020 06 08.
Article in English | MEDLINE | ID: mdl-32507112

ABSTRACT

BACKGROUND: On January 30, COVID-19 was declared a Public Health Emergency of International Concern-a week after Singapore's first imported case and 5 days before local transmission. The National University Hospital (NUH) is Singapore's third largest hospital with 1200 beds, heavy clinical workloads, and major roles in research and teaching. MAIN BODY: With memories of SARS still vivid, there was an urgent requirement for the NUH Division of Infectious Diseases to adapt-undergoing major reorganization to face rapidly changing priorities while ensuring usual essential services and standards. Leveraging on individual strengths, our division mobilized to meet the demands of COVID-19 while engaging in high-level coordination, strategy, and advocacy. We present our experience of the 60 days since the nation's first case. During this time, our hospital has managed 3030 suspect cases, including 1300 inpatients, 37 confirmed cases, and overseen 4384 samples tested for COVID-19. CONCLUSION: Complex hospital adaptations were supported by an unprecedented number of workflows and coordination channels essential to safe and effective operations. The actions we describe, aligned with international recommendations and emerging evidence-based best practices, may serve as a framework for other divisions and institutions facing the spread of COVID-19 globally.


Subject(s)
Coronavirus Infections , Hospitals, University , Organizational Innovation , Pandemics , Pneumonia, Viral , Public Health , Academic Medical Centers , Betacoronavirus , COVID-19 , Communicable Diseases , Coronavirus Infections/epidemiology , Delivery of Health Care , Hospitals, University/organization & administration , Humans , Pneumonia, Viral/epidemiology , SARS-CoV-2 , Singapore/epidemiology , Workload
7.
Headache ; 60(5): 864-877, 2020 05.
Article in English | MEDLINE | ID: mdl-32232837

ABSTRACT

BACKGROUND: Coronavirus disease 2019 (COVID-19) is an emerging infectious disease of pandemic proportions. Healthcare workers in Singapore working in high-risk areas were mandated to wear personal protective equipment (PPE) such as N95 face mask and protective eyewear while attending to patients. OBJECTIVES: We sought to determine the risk factors associated with the development of de novo PPE-associated headaches as well as the perceived impact of these headaches on their personal health and work performance. The impact of COVID-19 on pre-existing headache disorders was also investigated. METHODS: This is a cross-sectional study among healthcare workers at our tertiary institution who were working in high-risk hospital areas during COVID-19. All respondents completed a self-administered questionnaire. RESULTS: A total of 158 healthcare workers participated in the study. Majority [126/158 (77.8%)] were aged 21-35 years. Participants included nurses [102/158 (64.6%)], doctors [51/158 (32.3%)], and paramedical staff [5/158 (3.2%)]. Pre-existing primary headache diagnosis was present in about a third [46/158 (29.1%)] of respondents. Those based at the emergency department had higher average daily duration of combined PPE exposure compared to those working in isolation wards [7.0 (SD 2.2) vs 5.2 (SD 2.4) hours, P < .0001] or medical ICU [7.0 (SD 2.2) vs 2.2 (SD 0.41) hours, P < .0001]. Out of 158 respondents, 128 (81.0%) respondents developed de novo PPE-associated headaches. A pre-existing primary headache diagnosis (OR = 4.20, 95% CI 1.48-15.40; P = .030) and combined PPE usage for >4 hours per day (OR 3.91, 95% CI 1.35-11.31; P = .012) were independently associated with de novo PPE-associated headaches. Since COVID-19 outbreak, 42/46 (91.3%) of respondents with pre-existing headache diagnosis either "agreed" or "strongly agreed" that the increased PPE usage had affected the control of their background headaches, which affected their level of work performance. CONCLUSION: Most healthcare workers develop de novo PPE-associated headaches or exacerbation of their pre-existing headache disorders.


Subject(s)
Coronavirus Infections/prevention & control , Headache/epidemiology , Health Personnel/statistics & numerical data , Pandemics/prevention & control , Personal Protective Equipment/adverse effects , Pneumonia, Viral/prevention & control , Adult , COVID-19 , Coronavirus Infections/epidemiology , Cross-Sectional Studies , Female , Humans , Male , Pneumonia, Viral/epidemiology , Singapore/epidemiology , Surveys and Questionnaires , Young Adult
8.
CMAJ ; 189(5): E217, 2017 02 06.
Article in English | MEDLINE | ID: mdl-28246267
10.
Compr Psychiatry ; 46(5): 340-52, 2005.
Article in English | MEDLINE | ID: mdl-16122534

ABSTRACT

This study investigated a hypothesized correlation between contradictory responses from parental figures perceived in present-day interactions by adult subjects and the diagnosis of borderline personality disorder (BPD). One hundred subjects were given a questionnaire designed to assess the frequency of perceived parental response patterns divided into appropriate, conflicting, polarized, and neglectful categories. The BPD and a group subthreshold for the disorder endorsed significantly more conflicting and fewer appropriate responses for the first parental figure rated than did both patient control subjects and normal control subjects without BPD; a trend toward similar results was found for the second parental figure also. The frequency of polarized and neglectful responses was not significantly different among the groups. There was indirect evidence that BPD subjects did not engage in the defense mechanism of "splitting" when filling out the questionnaire. These results suggest that contradictory family communication patterns might be considered in models of ongoing reinforcement for dysfunctional BPD behavior.


Subject(s)
Attitude , Borderline Personality Disorder/psychology , Communication , Parents , Social Perception , Adult , Diagnostic and Statistical Manual of Mental Disorders , Family/psychology , Female , Humans , Interpersonal Relations , Male , Middle Aged , Surveys and Questionnaires
11.
CMAJ ; 172(4): 447, 2005 Feb 15.
Article in English | MEDLINE | ID: mdl-15710917
12.
Pediatr Dermatol ; 22(1): 60-3, 2005.
Article in English | MEDLINE | ID: mdl-15660900

ABSTRACT

Phrynoderma is a distinctive form of follicular hyperkeratosis associated with nutritional deficiency. Although originally thought to represent vitamin A deficiency, several studies have demonstrated multiple etiologies. Characteristic skin lesions are hyperkeratotic papules that first appear on the extensor surfaces of the extremities, shoulders, and buttocks. We report a 14-month-old boy with malnourishment and hyperkeratotic papules and plaques with histologic changes typical of phrynoderma. Despite an extensive evaluation, a specific nutritional deficiency was not identified. Phrynoderma is believed to be a manifestation of severe malnutrition, not necessarily accompanying low vitamin A levels. While the literature supports a link between phrynoderma and vitamins E, B, A, and essential fatty acids general malnutrition seems to be the strongest association. The clinical picture typically improves with enhanced nutritional status. Phrynoderma must be considered in the differential diagnosis in patients with extensor surface hyperkeratotic papules and plaques in the setting of malnourishment and should prompt the clinician to evaluate cell markers of nutritional status, not just vitamin A. We believe this patient exemplifies the conundrum that faces clinicians in evaluating patients with extensor surface predominant hyperkeratotic papules and plaques in the setting of malnourishment.


Subject(s)
Darier Disease/etiology , Infant Nutrition Disorders/complications , Failure to Thrive/etiology , Humans , Infant , Keratosis/etiology , Male , Vitamin A Deficiency/complications
13.
J Invest Dermatol ; 122(5): 1091-5, 2004 May.
Article in English | MEDLINE | ID: mdl-15140208

ABSTRACT

All patients at the Medical College of Wisconsin Affiliated Hospitals with a new diagnosis of bullous pemphigoid (BP) between May 1, 1997 and September 1, 2002 were included in this study. The age at onset, date of death or date of last follow-up visit, mode of treatment, co-morbidities, and initial and follow-up hospitalizations were noted. Thirty-eight new patients were identified and complete follow-up data were obtained on 37 of the patients. Patients were followed a minimum of 1 y or until the time of death. The mean duration of follow-up was 20 mo. Kaplan-Meier analysis of our population indicated a 1-y survival probability of 88.96% (standard error 5.21%), with a 95% confidence interval (75.6%, 94.2%). This survival rate was considerably higher than that recently reported in several studies from Europe (29%-41% first year mortality). Although the age at onset and co-morbidities of our patients were similar to those in the European studies, the rate of hospitalization of our patients was much lower than that of patients from Europe (1.5 d per patient vs 11-25 d per patient). This study suggests that differences in practice patterns may be an important factor in the reduced mortality rate in US BP patients compared with Europe.


Subject(s)
Academic Medical Centers/statistics & numerical data , Pemphigoid, Bullous/mortality , Adult , Aged , Aged, 80 and over , Female , Follow-Up Studies , Humans , Male , Middle Aged , Retrospective Studies , Survival Analysis , Wisconsin/epidemiology
SELECTION OF CITATIONS
SEARCH DETAIL
...