Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Am J Med Qual ; 34(5): 488-493, 2019.
Article in English | MEDLINE | ID: mdl-31479293

ABSTRACT

Advances in neonatology led to survival of micro-preemies, who need central lines. Central line-associated bloodstream infection (CLABSI) causes prolonged hospitalization, morbidities, and mortality. Health care team education decreases CLABSIs. The objective was to decrease CLABSIs using evidence-based measures. The retrospective review compared CLABSI incidence during and after changes in catheter care. In April 2011, intravenous (IV) tubing changed from Interlink to Clearlink; IV tubing changing interval increased from 24 to 72 hours. CLABSIs increased. The following measures were implemented: July 2011, reeducation of neonatal intensive care staff on Clearlink; August 2011, IV tubing changing interval returned to 24 hours; September 2011, changed from Clearlink back to Interlink; November 2011, review of entire IV process and in-service on hand hygiene; December 2011, competencies on IV access for all nurses. CLABSIs were compared during and after interventions. Means were compared using the t test and ratios using the χ2 test; P <.05. CLABSIs decreased from 4.4/1000 to 0/1000 catheter-days; P < .05. Evidence-based interventions reduced CLABSIs.

2.
Am J Med Qual ; 31(2): 133-8, 2016.
Article in English | MEDLINE | ID: mdl-25372275

ABSTRACT

Advances in neonatology led to survival of micro-preemies, who need central lines. Central line-associated bloodstream infection (CLABSI) causes prolonged hospitalization, morbidities, and mortality. Health care team education decreases CLABSIs. The objective was to decrease CLABSIs using evidence-based measures. The retrospective review compared CLABSI incidence during and after changes in catheter care. In April 2011, intravenous (IV) tubing changed from Interlink to Clearlink; IV tubing changing interval increased from 24 to 72 hours. CLABSIs increased. The following measures were implemented: July 2011, reeducation of neonatal intensive care staff on Clearlink; August 2011, IV tubing changing interval returned to 24 hours; September 2011, changed from Clearlink back to Interlink; November 2011, review of entire IV process and in-service on hand hygiene; December 2011, competencies on IV access for all nurses. CLABSIs were compared during and after interventions. Means were compared using the t test and ratios using the χ(2) test; P <.05. CLABSIs decreased from 4.4/1000 to 0/1000 catheter-days; P < .05. Evidence-based interventions reduced CLABSIs.


Subject(s)
Catheter-Related Infections/prevention & control , Infection Control/organization & administration , Intensive Care Units, Neonatal/organization & administration , Birth Weight , Evidence-Based Medicine , Female , Gestational Age , Humans , Infant, Newborn , Infection Control/instrumentation , Inservice Training , Male , Quality Improvement/organization & administration , Retrospective Studies , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...