Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-18161414

ABSTRACT

The standard technique for measurement of millimeter wave fields utilizes an open-ended waveguide attached to a HP power meter. The alignment of the waveguide with the propagation (K) vector is critical to making accurate measurements. Using this technique, it is difficult and time consuming to make a detailed map of average incident power density over areas of biological interest and the spatial resolution of this instrument does not allow accurate measurements in non-uniform fields. For biological experiments, it is important to know the center field average incident power density and the distribution over the exposed area. Two 4 ft x 4 ft x 1/32 inch sheets of carbon loaded Teflon (CLT) (one 15% carbon and one 25% carbon) were procured and a series of tests to determine the usefulness of CLT in defining fields in the millimeter wavelength range was initiated. Since the CLT was to be used both in the laboratory, where the environment was well controlled, and in the field, where the environment could not be controlled, tests were made to determine effects of change in environmental conditions on ability to use CLT as a millimeter wave dosimeter. The empirical results of this study indicate CLT to be an effective dosimeter for biological experiments both in the laboratory and in the field.


Subject(s)
Carbon/chemistry , Electromagnetic Fields , Microwaves , Polytetrafluoroethylene/chemistry
2.
Bioelectromagnetics ; 28(5): 406-8, 2007 Jul.
Article in English | MEDLINE | ID: mdl-17486633

ABSTRACT

The study presented in this article was designed to complete a dosimetry protocol required to establish the RF exposure levels at 100 MHz for measurement of the effect on cognition in human volunteers near the resonant frequency in seated positions. The results are compared with those reported previously using the same experimental procedures, except with the vertically radiating dipole antenna and corner reflector raised by .30 m to the vertical center of the anechoic chamber. The average whole body SAR for the high and low SAR conditions used in the previous study was achieved with a 12% increase in transmitter forward power. However, the incident power density averaged over the body was increased by 42%, from 40 and 80 W/m(2) in the previous study to 57 and 113 W/m(2) in the current study to achieve the same whole body average SAR used in the previous study. The differences in field patterns and field intensities between the previous and current studies were introduced by interactions between the E-field and RF absorbers in the floor and ceiling, which represent resonant structures at 100 MHz.


Subject(s)
Radio Waves/adverse effects , Whole-Body Irradiation , Absorption , Humans , Microwaves/adverse effects , Models, Biological , Phantoms, Imaging , Whole-Body Counting
3.
Bioelectromagnetics ; 26(6): 440-7, 2005 Sep.
Article in English | MEDLINE | ID: mdl-15931686

ABSTRACT

This study reports the dosimetry performed to support an experiment that measured physiological responses of seated volunteer human subjects exposed to 220 MHz fields. Exposures were performed in an anechoic chamber which was designed to provide uniform fields for frequencies of 100 MHz or greater. A vertical half-wave dipole with a 90 degrees reflector was used to optimize the field at the subject's location. The vertically polarized E field was incident on the dorsal side of the phantoms and human volunteers. The dosimetry plan required measurement of stationary probe drift, field strengths as a function of distance, electric and magnetic field maps at 200, 225, and 250 cm from the dipole antenna, and specific absorption rate (SAR) measurements using a human phantom, as well as theoretical predictions of SAR with the finite difference time domain (FDTD) method. A NBS (National Bureau of Standards, now NIST, National Institute of Standards and Technology, Boulder, CO) 10 cm loop antenna was positioned 150 cm to the right, 100 cm above and 60 cm behind the subject (toward the transmitting antenna) and was read prior to each subject's exposure and at 5 min intervals during all RF exposures. Transmitter stability was determined by measuring plate voltage, plate current, screen voltage and grid voltage for the driver and final amplifiers before and at 5 min intervals throughout the RF exposures. These dosimetry measurements assured accurate and consistent exposures. FDTD calculations were used to determine SAR distribution in a seated human subject. This study reports the necessary dosimetry to precisely control exposure levels for studies of the physiological consequences of human volunteer exposures to 220 MHz.


Subject(s)
Electromagnetic Fields , Posture , Radiation Dosage , Whole-Body Irradiation , Absorption , Electromagnetic Phenomena/instrumentation , Forecasting , Humans , Models, Biological , Phantoms, Imaging , Radiometry , Time Factors
4.
Bioelectromagnetics ; 26(6): 448-61, 2005 Sep.
Article in English | MEDLINE | ID: mdl-15906370

ABSTRACT

Since 1994, our research has demonstrated how thermophysiological responses are mobilized in human volunteers exposed to three radio frequencies, 100, 450, and 2450 MHz. A significant gap in this frequency range is now filled by the present study, conducted at 220 MHz. Thermoregulatory responses of heat loss and heat production were measured in six adult volunteers (five males, one female, aged 24-63 years) during 45 min whole body dorsal exposures to 220 MHz radio frequency (RF) energy. Three power densities (PD = 9, 12, and 15 mW/cm(2) [1 mW/cm(2) = 10 W/m(2)], whole body average normalized specific absorption rate [SAR] = 0.045 [W/kg]/[mW/cm(2)] = 0.0045 [W/kg]/[W/m(2)]) were tested at each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C) plus T(a) controls (no RF). Measured responses included esophageal (T(esoph)) and seven skin temperatures (T(sk)), metabolic rate (M), local sweat rate, and local skin blood flow (SkBF). Derived measures included heart rate (HR), respiration rate, and total evaporative water loss (EWL). Finite difference-time domain (FDTD) modeling of a seated 70 kg human exposed to 220 MHz predicted six localized "hot spots" at which local temperatures were also measured. No changes in M occurred under any test condition, while T(esoph) showed small changes (< or =0.35 degrees C) but never exceeded 37.3 degrees C. As with similar exposures at 100 MHz, local T(sk) changed little and modest increases in SkBF were recorded. At 220 MHz, vigorous sweating occurred at PD = 12 and 15 mW/cm(2), with sweating levels higher than those observed for equivalent PD at 100 MHz. Predicted "hot spots" were confirmed by local temperature measurements. The FDTD model showed the local SAR in deep neural tissues that harbor temperature-sensitive neurons (e.g., brainstem, spinal cord) to be greater at 220 than at 100 MHz. Human exposure at both 220 and 100 MHz results in far less skin heating than occurs during exposure at 450 MHz. However, the exposed subjects thermoregulate efficiently because of increased heat loss responses, particularly sweating. It is clear that these responses are controlled by neural signals from thermosensors deep in the brainstem and spinal cord, rather than those in the skin.


Subject(s)
Body Temperature Regulation/radiation effects , Electromagnetic Fields , Whole-Body Irradiation , Adult , Body Temperature/radiation effects , Brain Stem/radiation effects , Energy Metabolism/radiation effects , Esophagus/radiation effects , Female , Heart Rate/radiation effects , Humans , Male , Middle Aged , Models, Biological , Neurons/radiation effects , Radiation Dosage , Regional Blood Flow/radiation effects , Respiration/radiation effects , Skin/blood supply , Skin/radiation effects , Skin Temperature/radiation effects , Spinal Cord/radiation effects , Sweating/radiation effects , Water Loss, Insensible/radiation effects
5.
Bioelectromagnetics ; 24(7): 489-501, 2003 Oct.
Article in English | MEDLINE | ID: mdl-12955754

ABSTRACT

Thermophysiological responses of heat production and heat loss were measured in seven adult volunteers (six males and one female, aged 31-74 years) during 45 min dorsal exposures of the whole body to 100 MHz continuous wave (CW) radio frequency (RF) energy. Three power densities (PD) (average PD = 4, 6, and 8 mW/cm(2); whole body specific absorption rate [SAR] = 0.068 [W/kg]/[mW/cm(2)]) were tested in each of three ambient temperatures (T(a) = 24, 28, and 31 degrees C), as well as in T(a) controls (no RF). A standardized protocol (30 min baseline, 45 min RF or sham exposure, 10 min baseline) was used. Measured responses included esophageal and seven skin temperatures, metabolic heat production, local sweat rate, and local skin blood flow. No changes in metabolic heat production occurred under any test condition. Unlike published results of similar exposures at 450 and 2450 MHz, local skin temperatures, even those on the back that were irradiated directly, changed little or not at all during 100 MHz exposures. The sole exception was the temperature of the ankle skin, which increased by 3-4 degrees C in some subjects at PD = 8 mW/cm(2). During the 45 min RF exposure, esophageal temperature showed modest changes (range = -0.15 to 0.13 degrees C) and never exceeded 37.2 degrees C. Thermoregulation was principally controlled by appropriate increases in evaporative heat loss (sweating) and, to a lesser extent, by changes in skin blood flow. Because of the deep penetration of RF energy at this frequency, effectively bypassing the skin, these changes must have been stimulated by thermal receptors deep in the body rather than those located in the skin.


Subject(s)
Body Temperature/radiation effects , Esophagus/radiation effects , Radio Waves , Skin Temperature/radiation effects , Sweating/radiation effects , Thermogenesis/radiation effects , Whole-Body Irradiation/methods , Adult , Aged , Dose-Response Relationship, Radiation , Female , Humans , Male , Middle Aged , Radiation Dosage , Radiometry/methods , Skin/blood supply , Skin/radiation effects , Thermography/methods
6.
Bioelectromagnetics ; 24(7): 502-9, 2003 Oct.
Article in English | MEDLINE | ID: mdl-12955755

ABSTRACT

This study reports the dosimetry performed to support an experiment that measured physiological responses of volunteer human subjects exposed to the resonant frequency for a seated human adult at 100 MHz. Exposures were performed in an anechoic chamber which was designed to provide uniform fields for frequencies of 100 MHz or greater. A half wave dipole with a 90 degrees reflector was used to optimize the field at the subject location. The dosimetry plan required measurement of transmitter harmonics, stationary probe drift, field strengths as a function of distance, electric and magnetic field maps at 200, 225, and 250 cm from the dipole antenna, and specific absorption rate (SAR) measurements using a human phantom, as well as theoretical predictions of SAR with the finite difference time domain (FDTD) method. On each exposure test day, a measurement was taken at 225 cm on the beam centerline with a NBS E field probe to assure consistently precise exposures. A NBS 10 cm loop antenna was positioned 150 cm to the right, 100 cm above, and 60 cm behind the subject and was read at 5 min intervals during all RF exposures. These dosimetry measurements assured accurate and consistent exposures. FDTD calculations were used to determine SAR distribution in a seated human subject. This study reports the necessary dosimetry for work on physiological consequences of human volunteer exposures to 100 MHz.


Subject(s)
Models, Biological , Radio Waves , Whole-Body Counting/instrumentation , Whole-Body Counting/methods , Whole-Body Irradiation/methods , Adult , Computer Simulation , Humans , Male , Radiation Dosage , Reproducibility of Results , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL
...