1.
Clin Chem ; 65(8): 1006-1014, 2019 08.
Article in English | MEDLINE | ID: mdl-31118187

ABSTRACT

OBJECTIVES: We sought to evaluate diagnostic accuracy of a high-sensitivity cardiac troponin I (hs-cTnI) assay for acute coronary syndromes (ACS) in the emergency department (ED). The assay has high precision at low concentrations and can detect cTnI in 96.8% of healthy individuals. METHODS: In successive prospective multicenter studies ("testing" and "validation"), we included ED patients with suspected ACS. We drew blood for hs-cTnI [Singulex Clarity® cTnI; 99th percentile, 8.67 ng/L; limit of detection (LoD), 0.08 ng/L] on arrival. Patients also underwent hs-cTnT (Roche Elecsys) testing over ≥3 h. The primary outcome was an adjudicated diagnosis of ACS, defined as acute myocardial infarction (AMI; prevalent or incident), death, or revascularization within 30 days. RESULTS: The testing and validation studies included 665 and 2470 patients, respectively, of which 94 (14.1%) and 565 (22.9%) had ACS. At a 1.5-ng/L cutoff, hs-cTnI had good sensitivity for AMI in both studies (98.7% and 98.1%, respectively) and would have "ruled out" 40.1% and 48.9% patients. However, sensitivity was lower for ACS (95.7% and 90.6%, respectively). At a 0.8-ng/L cutoff, sensitivity for ACS was higher (97.5% and 97.9%, ruling out 28.6% patients in each cohort). The hs-cTnT assay had similar performance at the LoD (24.6% ruled out; 97.2% sensitivity for ACS). CONCLUSIONS: The hs-cTnI assay could immediately rule out AMI in 40% of patients and ACS in >25%, with similar accuracy to hs-cTnT at the LoD. Because of its high precision at low concentrations, this hs-cTnI assay has favorable characteristics for this clinical application.


Subject(s)
Myocardial Infarction/blood , Troponin I/blood , Troponin T/blood , Aged , Emergency Service, Hospital , Female , Humans , Male , Middle Aged , Myocardial Infarction/mortality , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
2.
Heart ; 105(10): 768-774, 2019 05.
Article in English | MEDLINE | ID: mdl-30636217

ABSTRACT

OBJECTIVES: The rapid turnaround time of point-of-care (POC) cardiac troponin (cTn) assays is highly attractive for crowded emergency departments (EDs). We evaluated the diagnostic accuracy of the Troponin-only Manchester Acute Coronary Syndromes (T-MACS) decision aid with a POC cTn assay. METHODS: In a prospective diagnostic accuracy study at eight EDs, we included patients with suspected acute coronary syndromes (ACS). Blood drawn on arrival and 3 hours later was analysed for POC cTnI (i-Stat, Abbott Point of Care). The primary outcome was a diagnosis of ACS, which included both an adjudicated diagnosis of acute myocardial infarction (AMI) based on serial laboratory cTn testing and major adverse cardiac events (death, AMI or coronary revascularisation) within 30 days. RESULTS: Of 716 patients included, 105 (14.7%) had ACS. Using serial POC cTnI concentrations over 3 hours could have 'ruled out' ACS in 198 (31.2%) patients with a sensitivity of 99.0% (95% CI 94.4% to 100.0%) and negative predictive value 99.5% (95% CI 96.5% to 99.9%). No AMIs were missed. T-MACS 'ruled in' ACS for 65 (10.4%) patients with a positive predictive value of 91.2% (95% CI 82.1% to 95.9%) and specificity 98.9% (97.6% to 99.6%). CONCLUSION: With a POC cTnI assay, T-MACS could 'rule out' ACS for approximately one-third of patients within 3 hours while 'ruling in' ACS for another 10%. The rapid turnaround time and portability of the POC assay make this an attractive pathway for use in crowded EDs or urgent care centres. Future work should also evaluate use in the prehospital environment.


Subject(s)
Acute Coronary Syndrome/diagnosis , Decision Support Techniques , Point-of-Care Testing , Troponin I/blood , Acute Coronary Syndrome/blood , Adult , Aged , Aged, 80 and over , Biomarkers/blood , Emergency Service, Hospital , England , Female , Humans , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Risk Assessment , Risk Factors , Time Factors , Up-Regulation , Workflow