Cardiovasc Revasc Med ; 35: 85-90, 2022 02.
Article in English | MEDLINE | ID: mdl-33781677

ABSTRACT

BACKGROUND: The Scoreflex NC scoring angioplasty catheter is designed with a short rapid-exchange tip distal to a non-compliant, high-pressure balloon and an integral wire outside of the balloon, such that the guidewire and the integral wire act as scoring elements during balloon inflation. The external scoring elements enable a focal stress pattern facilitating expansion of resistant lesions at lower pressures using a focused force angioplasty effect. METHODS: Patients undergoing elective percutaneous coronary intervention (PCI) were enrolled in a prospective, single-arm study conducted at 12 centers in the United States. The primary endpoint was device procedural success, defined as the composite of successful device delivery to the target lesion with balloon inflation and deflation; absence of vessel perforation, flow-limiting dissection or reduction in TIMI flow from baseline; and achievement of final TIMI 3 flow. RESULTS: Among 200 patients (234 lesions), lesion complexities included: bifurcation disease (37.6%), moderate/severe calcification (36.6%), and total occlusions (5.0%). Successful delivery to the target lesion, inflation and removal of the balloon catheter was achieved in 95.5% of patients (191/200). Procedural success was achieved in 93.5% (187/200) of patients, and final TIMI 3 flow was observed in 99.0% of cases (198/200). No unanticipated device-related events occurred. In-hospital major adverse events were reported in 4.5% of patients (9/200), related to periprocedural myocardial infarction (8/200, 4.0%) and target lesion revascularization (1/200, 0.5%). CONCLUSIONS: Among patients undergoing elective PCI and with varied lesion complexity, these results support the safety and effectiveness of a dilation strategy using the Scoreflex NC scoring catheter.


Subject(s)
Myocardial Infarction , Percutaneous Coronary Intervention , Angioplasty, Balloon, Coronary/adverse effects , Catheters , Coronary Angiography , Humans , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Prospective Studies , Treatment Outcome , United States
2.
JACC Cardiovasc Interv ; 10(2): 147-156, 2017 01 23.
Article in English | MEDLINE | ID: mdl-28104208

ABSTRACT

OBJECTIVES: This study sought to assess the safety and effectiveness of the drug-filled stent (DFS) (Medtronic, Santa Rosa, California) in the treatment of patients with coronary artery disease. BACKGROUND: Polymer-free drug-eluting stents have the potential to improve clinical outcomes and facilitate shorter durations of dual antiplatelet therapy. The polymer-free DFS is made from a trilayered continuous wire with an outer cobalt chromium layer, a middle tantalum layer, and an inner lumen coated with sirolimus. Small laser-drilled holes on the abluminal stent surface control drug elution. METHODS: The RevElution trial enrolled 100 patients with de novo coronary lesions 2.25 to 3.50 mm in diameter and length ≤27 mm in 2 cohorts of 50 patients for angiographic, intravascular ultrasound, and clinical assessment at 9 or 24 months, with optical coherence tomography performed in a subset of 30 patients at each time period. The primary endpoint was angiographic in-stent late lumen loss at 9 months compared with Resolute zotarolimus-eluting stent (Medtronic) historical control data. RESULTS: Fifty patients with 56 lesions were treated with DFS in the 9-month cohort. In-stent late lumen loss was 0.26 ± 0.28 mm for DFS and 0.36 ± 0.52 mm for Resolute (pnoninferiority <0.001). The binary angiographic restenosis rate was 0%. Median stent strut coverage by optical coherence tomography was 91.4%, 95.6%, and 99.1% at 1, 3, and 9 months, respectively. One non-Q-wave myocardial infarction occurred, with a 9-month target lesion failure rate of 2.1%. No stent thrombosis occurred. CONCLUSIONS: At 9 months, the polymer-free DFS was safe and effective with high rates of early strut coverage and noninferior late lumen loss compared to Resolute. (Medtronic RevElution Trial [RevElution]; NCT02480348).


Subject(s)
Coronary Angiography , Coronary Artery Disease/therapy , Coronary Restenosis/diagnostic imaging , Coronary Vessels/diagnostic imaging , Drug-Eluting Stents , Percutaneous Coronary Intervention/instrumentation , Tomography, Optical Coherence , Ultrasonography, Interventional , Australia , Chromium Alloys , Coronary Artery Disease/diagnostic imaging , Coronary Restenosis/etiology , Coronary Thrombosis/diagnostic imaging , Coronary Thrombosis/etiology , Drug Therapy, Combination , Female , Humans , Latin America , Male , Middle Aged , Myocardial Infarction/diagnostic imaging , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Platelet Aggregation Inhibitors/administration & dosage , Predictive Value of Tests , Prosthesis Design , Risk Factors , Singapore , Sirolimus/administration & dosage , Sirolimus/analogs & derivatives , Tantalum , Time Factors , Treatment Outcome
3.
JACC cardiovasc. interv ; 10(2): 147-156, 2017. graf, ilus, tab
Article in English | Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1064052

ABSTRACT

OBJECTIVES:This study sought to assess the safety and effectiveness of the drug-filled stent (DFS) (Medtronic, Santa Rosa, California) in the treatment of patients with coronary artery disease.BACKGROUND:Polymer-free drug-eluting stents have the potential to improve clinical outcomes and facilitate shorter durations of dual antiplatelet therapy. The polymer-free DFS is made from a trilayered continuous wire with an outer cobalt chromium layer, a middle tantalum layer, and an inner lumen coated with sirolimus. Small laser-drilled holes on the abluminal stent surface control drug elution.METHODS:The RevElution trial enrolled 100 patients with de novo coronary lesions 2.25 to 3.50 mm in diameter and length ≤27 mm in 2 cohorts of 50 patients for angiographic, intravascular ultrasound, and clinical assessment at 9 or 24 months, with optical coherence tomography performed in a subset of 30 patients at each time period. The primary endpoint was angiographic in-stent late lumen loss at 9 months compared with Resolute zotarolimus-eluting stent (Medtronic) historical control data...


Subject(s)
Percutaneous Coronary Intervention , Drug-Eluting Stents