Australas Phys Eng Sci Med ; 35(4): 485-9, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23208619

ABSTRACT

Daily quality assurance procedures are an essential part of radiotherapy medical physics. Devices such as the Sun Nuclear, DQA3 are effective tools for analysis of daily dosimetry including flatness, symmetry, energy, field size and central axis radiation dose measurement. The DQA3 can be used on the treatment couch of the linear accelerator or on a dedicated table/bed for superficial and orthovoltage x-ray machines. This device is levelled using its dedicated feet. This work has shown that depending on the quantity of backscatter material behind the DQA3 device, the position of the levelling feet can affect the measured central axis dose by up to 1.8 % (250 kVp and 6 MV) and that the introduction of more backscatter material behind the DQA3 can lead to up to 7.2 % (6 MV) variations in measured central axis dose. In conditions where no backscatter material is present, dose measurements can vary up to 1 %. As such this work has highlighted the need to keep the material behind the DQA3 device constant as well as maintaining the accuracy of the feet position on the device to effectively measure the most accurate daily constancy achievable. Results have also shown that variations in symmetry and energy calculations of up to 1 % can occur if the device is not levelled appropriately. As such, we recommend the position of the levelling feet on the device be as close as possible to the device so that a constant distance is kept between the DQA3 and the treatment couch and thus minimal levelling variations also occur. We would also recommend having no extra backscattering material behind the DQA3 device during use to minimise any variations which might occur from these backscattering effects.


Subject(s)
Artifacts , Quality Assurance, Health Care/methods , Quality Assurance, Health Care/standards , Radiometry/instrumentation , Radiometry/methods , Australia , Equipment Design , Equipment Failure Analysis , Reproducibility of Results , Scattering, Radiation , Sensitivity and Specificity
2.
J Appl Clin Med Phys ; 13(5): 3957, 2012 Sep 06.
Article in English | MEDLINE | ID: mdl-22955661

ABSTRACT

Epson Desktop scanners have been quoted as devices which match the characteristics required for the evaluation of radiation dose exposure by radiochromic films. Specifically, models such as the 10000XL have been used successfully for image analysis and are recommended by ISP for dosimetry purposes. This note investigates and compares the scanner characteristics of three Epson desktop scanner models including the Epson 10000XL, V700, and V330. Both of the latter are substantially cheaper models capable of A4 scanning. As the price variation between the V330 and the 10000XL is 20-fold (based on Australian recommended retail price), cost savings by using the cheaper scanners may be warranted based on results. By a direct comparison of scanner uniformity and reproducibility we can evaluate the accuracy of these scanners for radiochromic film dosimetry. Results have shown that all three scanners can produce adequate scanner uniformity and reproducibility, with the inexpensive V330 producing a standard deviation variation across its landscape direction of 0.7% and 1.2% in the portrait direction (reflection mode). This is compared to the V700 in reflection mode of 0.25% and 0.5% for landscape and portrait directions, respectively, and 0.5% and 0.8% for the 10000XL. In transmission mode, the V700 is comparable in reproducibility to the 10000XL for portrait and landscape mode, whilst the V330 is only capable of scanning in the landscape direction and produces a standard deviation in this direction of 1.0% compared to 0.6% (V700) and 0.25% (10000XL). Results have shown that the V700 and 10000XL are comparable scanners in quality and accuracy with the 10000XL obviously capable of imaging over an A3 area as opposed to an A4 area for the V700. The V330 scanner produced slightly lower accuracy and quality with uncertainties approximately twice as much as the other scanners. However, the results show that the V330 is still an adequate scanner and could be used for radiation dosimetry purposes. As such, if budgetary requirements are limited, the V700 scanner would be the recommended option at a price eight times cheaper than the 10000XL; however, the V330 produces adequate results at a price which is 2.5 times cheaper again. This may be a consideration for smaller institutions or individuals working with radiochromic film dosimetry.


Subject(s)
Film Dosimetry/instrumentation , Quality Assurance, Health Care/methods , X-Ray Film , Film Dosimetry/methods , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
3.
Australas Phys Eng Sci Med ; 35(3): 321-8, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22972481

ABSTRACT

During in vivo dosimetry for megavoltage X-ray beams, detectors such as diodes, Thermo luminescent dosimeters (TLD's) and MOSFET devices are placed on the patient's skin. This of course will affect the skin dose delivered during that fraction of the treatment. Whilst the overall impact on increasing skin dose would be minimal, little has been quantified concerning the level of increase in absorbed dose, in vivo dosimeters produce when placed in the beams path. To this extent, measurements have been made and analysis performed on dose changes caused by MOSKIN, MOSFET, skin dose detectors. Maximum increases in skin dose were measured as 15 % for 6 MV X-rays and 10 % for 10 MV X-rays at the active crystal of the MOSKIN device which is the thickest part of the detector. This is compared to 32 and 26 % for a standard 1 mm thick LiF TLD at 10 × 10 cm(2) field size for 6 and 10 MV X-rays respectively. Radiochromic film, EBT2 has been shown to provide a high resolution 2 dimensional map of skin dose from these detectors and measures the effects of in vivo dosimeters used for radiotherapy dose assessment.


Subject(s)
Radiometry/instrumentation , Radiotherapy, High-Energy/instrumentation , Skin Physiological Phenomena , Equipment Design , Equipment Failure Analysis , Humans , Radiometry/methods , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity
4.
Australas Phys Eng Sci Med ; 34(3): 401-7, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21735295

ABSTRACT

A simple and reproducible method for increasing desktop scanner uniformity for the analysis of radiochromic films is presented. Scanner uniformity, especially in the non-scan direction, for transmission scanning is well known to be problematic for radiochromic film analysis and normally corrections need to be applied. These corrections are dependant on scanner coordinates and dose level applied which complicates dosimetry procedures. This study has highlighted that using reflectance scanning in combination with a matt, white backing material instead of the conventional gloss scanner finish, substantial increases in the scanner uniformity can be achieved within 90% of the scanning area. Uniformity within ±1% over the scanning area for our epsonV700 scanner tested was found. This is compared to within ±3% for reflection scanning with the gloss backing material and within ±4% for transmission scanning. The matt backing material used was simply 5 layers of standard quality white printing paper (80 g/m(2)). It was found that 5 layers was the optimal result for backing material however most of the improvements were seen with a minimum of 3 layers. Above 5 layers, no extra benefit was seen. This may eliminate the need to perform scanner corrections for position on the desktop scanners for radiochromic film dosimetry.


Subject(s)
Clinical Laboratory Techniques/methods , Film Dosimetry , Radiation Dosage , Calibration , Clinical Laboratory Techniques/instrumentation , Equipment Design , Film Dosimetry/instrumentation , Film Dosimetry/methods , Reference Standards , Reproducibility of Results , Research Design , X-Ray Film
5.
Phys Med ; 26(4): 216-9, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20149701

ABSTRACT

Gafchromic XRQA radiochromic film, is an effective tool for quality assurance and dose assessment in kilovoltage radiotherapy and diagnostic applications. Like other Gafchromic film products, XRQA film exhibits a variation in dose to reflected optical density response with angle of rotation when analysed with a light source that is partially or fully polarised such as a desktop scanner. Although warnings are not given on manufacturers specifications, this can affect dosimetry accuracy and we recommend that it is essential to scan all XRQA films in the same orientation. The effect is not as pronounced as EBT Gafchromic film. The magnitude of this variation has been measured and shown to be up to 16 ± 2% (1SD) using a fully linear polarised light source was seen with a 90° angle rotation. This would be the maximum variation seen on a desktop scanner with a fully polarised light source. For our standard desktop scanner (Epson v700) a mean variation of 2 ± 1% from 0 cGy to 20 cGy applied dose was measured as compared to 8 ± 2% for EBT Gafchromic. We recommend that to decrease uncertainty in dose measurement, accurate alignment of the calibration films to experimental films be performed on a regular basis. This is especially important if your desktop scanner has a high degree of polarization of its light source.


Subject(s)
Film Dosimetry/methods , Optical Phenomena