Phys Med Biol ; 64(16): 165012, 2019 08 21.
Article in English | MEDLINE | ID: mdl-31117063

ABSTRACT

This paper studies the sensitivity of a range of image texture parameters used in radiomics to: (i) the number of intensity levels, (ii) the method of quantisation to select the intensity levels and (iii) the use of an intensity threshold. 43 commonly used texture features were studied for the gross target volume outlined on the CT component of PET/CT scans of 50 patients with non-small cell lung carcinoma (NSCLC). All cases were quantised for all values between 4 and 128 intensity levels using four commonly used quantisation methods. All results were analysed with and without a threshold range of -200 HU to 300 HU. Cases were ranked for each texture feature and for all quantisation methods with the Spearman's rank correlation coefficient determined to evaluate stability. Results showed large fluctuations in ranking, particularly for low numbers of levels, differences between quantisation methods and with the use of a threshold, with values Spearman's Rank Correlation for many parameters below 0.2. Our results demonstrated the sensitivity of radiomics features to the parameters used during analysis and highlight the risk of low reproducibility comparing studies with slightly different parameters. In terms of the lung cancer CT datasets, this study supports the use of 128 intensity levels, the same uniform quantiser applied to all scans and thresholding of the data. It also supports several of the features recommended in the literature for such studies such as skewness and kurtosis. A recommended framework is presented for curation of the data analysis process to ensure stability of results.


Subject(s)
Biomarkers, Tumor/metabolism , Carcinoma, Non-Small-Cell Lung/diagnostic imaging , Carcinoma, Non-Small-Cell Lung/metabolism , Image Processing, Computer-Assisted , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/metabolism , Positron Emission Tomography Computed Tomography , Carcinoma, Non-Small-Cell Lung/pathology , Humans , Lung Neoplasms/pathology , Reproducibility of Results
2.
Br J Radiol ; 87(1042): 20140369, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25051978

ABSTRACT

Predicting a tumour's response to radiotherapy prior to the start of treatment could enhance clinical care management by enabling the personalization of treatment plans based on predicted outcome. In recent years, there has been accumulating evidence relating tumour texture to patient survival and response to treatment. Tumour texture could be measured from medical images that provide a non-invasive method of capturing intratumoural heterogeneity and hence could potentially enable a prior assessment of a patient's predicted response to treatment. In this article, work presented in the literature regarding texture analysis in radiotherapy in relation to survival and outcome is discussed. Challenges facing integrating texture analysis in radiotherapy planning are highlighted and recommendations for future directions in research are suggested.


Subject(s)
Neoplasms/diagnostic imaging , Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Tomography, X-Ray Computed/methods , Diagnostic Imaging , Humans , Neoplasms/pathology , Positron-Emission Tomography , Prognosis
3.
Med Phys ; 40(6): 061707, 2013 Jun.
Article in English | MEDLINE | ID: mdl-23718586

ABSTRACT

PURPOSE: Dose distribution measurement in clinical high dose rate (HDR) brachytherapy is challenging, because of the high dose gradients, large dose variations, and small scale, but it is essential to verify accurate treatment planning and treatment equipment performance. The authors compare and evaluate three dosimetry systems for potential use in brachytherapy dose distribution measurement: Ge-doped optical fibers, EBT3 Gafchromic film with multichannel analysis, and the radiochromic material PRESAGE(®) with optical-CT readout. METHODS: Ge-doped SiO2 fibers with 6 µm active core and 5.0 mm length were sensitivity-batched and their thermoluminescent properties used via conventional heating and annealing cycles. EBT3 Gafchromic film of 30 µm active thickness was calibrated in three color channels using a nominal 6 MV linear accelerator. A 48-bit transmission scanner and advanced multichannel analysis method were utilized to derive dose measurements. Samples of the solid radiochromic polymer PRESAGE(®), 60 mm diameter and 100 mm height, were analyzed with a parallel beam optical CT scanner. Each dosimetry system was used to measure the dose as a function of radial distance from a Co-60 HDR source, with results compared to Monte Carlo TG-43 model data. Each system was then used to measure the dose distribution along one or more lines through typical clinical dose distributions for cervix brachytherapy, with results compared to treatment planning system (TPS) calculations. Purpose-designed test objects constructed of Solid Water and held within a full-scatter water tank were utilized. RESULTS: All three dosimetry systems reproduced the general shape of the isolated source radial dose function and the TPS dose distribution. However, the dynamic range of EBT3 exceeded those of doped optical fibers and PRESAGE(®), and the latter two suffered from unacceptable noise and artifact. For the experimental conditions used in this study, the useful range from an isolated HDR source was 5-40 mm for fibers, 3-50 mm for EBT3, and 4-21 mm for PRESAGE(®). Fibers demonstrated some over-response at very low dose levels, suffered from volume averaging effects in the dose distribution measurement, and exhibited up to 9% repeatability variation over three repeated measurements. EBT3 demonstrated excellent agreement with Monte Carlo and TPS dose distributions, with up to 3% repeatability over three measurements. PRESAGE(®) gave promising results, being the only true 3D dosimeter, but artifacts and noise were apparent. CONCLUSIONS: The comparative response of three emerging dosimetry systems for clinical brachytherapy dose distribution measurement has been investigated. Ge-doped optical fibers have excellent spatial resolution for single-direction measurement but are currently too large for complex dose distribution assessment. The use of PRESAGE(®) with optical-CT readout gave promising results in the measurement of true 3D dose distributions but further development work is required to reduce noise and improve dynamic range for brachytherapy dose distribution measurements. EBT3 Gafchromic film with multichannel analysis demonstrated accurate and reproducible measurement of dose distributions in HDR brachytherapy. Calibrated dose measurements were possible with agreement within 1.5% of TPS dose calculations. The suitability of EBT3 as a dosimeter for 2D quality control or commissioning work has been demonstrated.


Subject(s)
Brachytherapy/instrumentation , Fiber Optic Technology/instrumentation , Film Dosimetry/instrumentation , Thermoluminescent Dosimetry/instrumentation , Equipment Design , Equipment Failure Analysis , Humans , Radiotherapy Dosage , Reproducibility of Results , Sensitivity and Specificity