Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 196
Filter
1.
Article in English | MEDLINE | ID: mdl-38876464

ABSTRACT

BACKGROUND: Vagal nerve stimulation (VNS) is an adjunctive therapy to pharmacological treatment in patients with drug-resistant epilepsy. This study aimed to assess the efficacy of VNS therapy for seizure frequency reduction and improving quality of life (QOL) measures in children with refractory epilepsy and to evaluate the correlation between the perspectives of families and those of the treating team. METHODS: This was a prospective cohort study conducted at Abha Maternity and Children's Hospital, Saudi Arabia, from 2018 to 2022. A total of 21 pediatric patients who completed one year of follow-up after VNS implantation were included. Patients were aged between 2 and 14 years, with a mean age of 8.14 ± 3.92; 11 (52.4%) patients were female. Family and physician assessments were collected blinded to each other using Clinical Global Impression of Improvement (CGI-I) scores and QOL assessments to evaluate the correlation between the families' and treating team's perspectives on VNS outcomes. RESULTS: In this study involving 21 patients with intractable epilepsy, VNS showed significant efficacy in reducing the frequency of seizures. VNS significantly reduced the number of seizures per week from a baseline median of 35 to a median of 0.25 at the end of the follow-up period, representing a dramatic reduction of 99.3% (p < 0.001). The number of emergency department visits per year decreased from a baseline median of 12 to a median of 2, a reduction of 83.3% (p < 0.001), whereas the number of hospital admissions per year decreased from a baseline median of 3 to a median of 1, a 66.7% decrease (p < 0.001). The number of antiepileptic medications taken decreased from a median of 4 to 3 (p < 0.001). Notably, 28.57% of the patients achieved complete seizure freedom, and 38% exhibited significant improvement, with at least 50% reduction in seizure frequency. Importantly, none of the patients experienced an escalation in seizure frequency following VNS treatment. The family and physician assessments showed varying degrees of alignment in perceptions, with "concentration" exhibiting a significant positive correlation (r = 0.498, p = 0.022), indicating noteworthy agreement, whereas verbal communication did not show a substantial correlation (r = -0.062, p = 0.791), indicating a divergence of views. CONCLUSION: VNS is a promising and well-tolerated therapy for individuals with intractable seizures, offering clinical benefits and potential enhancements in various aspects of QOL. The varying perceptions between family and physician assessments highlight the importance of considering multiple perspectives when evaluating treatment outcomes.

2.
Med Sci Monit ; 30: e944502, 2024 Jun 10.
Article in English | MEDLINE | ID: mdl-38857196

ABSTRACT

BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P≤0.05 were considered significant. RESULTS HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 µm). Differences between subgroups for Ra and Rq values were significant (P≤0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. CONCLUSIONS Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.


Subject(s)
Dental Materials , Dental Polishing , Steam , Sterilization , Surface Properties , Zirconium , Sterilization/methods , Humans , Dental Polishing/methods , Materials Testing/methods , Dental Restoration, Permanent/methods , Microscopy, Electron, Scanning/methods
3.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Article in English | MEDLINE | ID: mdl-38762747

ABSTRACT

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Subject(s)
Dental Impression Materials , Glutaral , Materials Testing , Polyvinyls , Siloxanes , Dental Impression Materials/chemistry , Polyvinyls/chemistry , Siloxanes/chemistry , Time Factors , Glutaral/chemistry , Dental Disinfectants/chemistry , Sodium Hypochlorite/chemistry , Disinfectants/chemistry , Chlorhexidine/chemistry , Surface Properties , Humans
4.
Photodiagnosis Photodyn Ther ; 47: 104225, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38821240

ABSTRACT

The global health issue of prostate cancer (PCa) requires better diagnosis and treatment. Photoacoustic imaging (PAI) may change PCa management. This review examines PAI's principles, diagnostic role, and therapeutic guidance. PAI uses optical light excitation and ultrasonic detection for high-resolution functional and molecular imaging. PAI uses endogenous and exogenous contrast agents to distinguish cancerous and benign prostate tissues with greater sensitivity and specificity than PSA testing and TRUS-guided biopsy. In addition to diagnosing, PAI can guide and monitor PCa therapy. Its real-time imaging allows precise biopsies and brachytherapy seed placement. Photoacoustic temperature imaging allows non-invasive monitoring of thermal therapies like cryotherapy, improving treatment precision and success. Transurethral illumination probes, innovative contrast agents, integration with other imaging modalities, and machine learning analysis are being developed to overcome depth and data complexity restrictions. PAI could become an essential tool for PCa diagnosis and therapeutic guidance as the field advances.


Subject(s)
Photoacoustic Techniques , Prostatic Neoplasms , Humans , Photoacoustic Techniques/methods , Male , Prostatic Neoplasms/therapy , Prostatic Neoplasms/diagnostic imaging
5.
Prehosp Disaster Med ; : 1-11, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38757150

ABSTRACT

OBJECTIVE: The aim of this study was to summarize the literature on the applications of machine learning (ML) and their performance in Emergency Medical Services (EMS). METHODS: Four relevant electronic databases were searched (from inception through January 2024) for all original studies that employed EMS-guided ML algorithms to enhance the clinical and operational performance of EMS. Two reviewers screened the retrieved studies and extracted relevant data from the included studies. The characteristics of included studies, employed ML algorithms, and their performance were quantitively described across primary domains and subdomains. RESULTS: This review included a total of 164 studies published from 2005 through 2024. Of those, 125 were clinical domain focused and 39 were operational. The characteristics of ML algorithms such as sample size, number and type of input features, and performance varied between and within domains and subdomains of applications. Clinical applications of ML algorithms involved triage or diagnosis classification (n = 62), treatment prediction (n = 12), or clinical outcome prediction (n = 50), mainly for out-of-hospital cardiac arrest/OHCA (n = 62), cardiovascular diseases/CVDs (n = 19), and trauma (n = 24). The performance of these ML algorithms varied, with a median area under the receiver operating characteristic curve (AUC) of 85.6%, accuracy of 88.1%, sensitivity of 86.05%, and specificity of 86.5%. Within the operational studies, the operational task of most ML algorithms was ambulance allocation (n = 21), followed by ambulance detection (n = 5), ambulance deployment (n = 5), route optimization (n = 5), and quality assurance (n = 3). The performance of all operational ML algorithms varied and had a median AUC of 96.1%, accuracy of 90.0%, sensitivity of 94.4%, and specificity of 87.7%. Generally, neural network and ensemble algorithms, to some degree, out-performed other ML algorithms. CONCLUSION: Triaging and managing different prehospital medical conditions and augmenting ambulance performance can be improved by ML algorithms. Future reports should focus on a specific clinical condition or operational task to improve the precision of the performance metrics of ML models.

6.
PeerJ Comput Sci ; 10: e1878, 2024.
Article in English | MEDLINE | ID: mdl-38660148

ABSTRACT

Hyperparameter tuning plays a pivotal role in the accuracy and reliability of convolutional neural network (CNN) models used in brain tumor diagnosis. These hyperparameters exert control over various aspects of the neural network, encompassing feature extraction, spatial resolution, non-linear mapping, convergence speed, and model complexity. We propose a meticulously refined CNN hyperparameter model designed to optimize critical parameters, including filter number and size, stride padding, pooling techniques, activation functions, learning rate, batch size, and the number of layers. Our approach leverages two publicly available brain tumor MRI datasets for research purposes. The first dataset comprises a total of 7,023 human brain images, categorized into four classes: glioma, meningioma, no tumor, and pituitary. The second dataset contains 253 images classified as "yes" and "no." Our approach delivers exceptional results, demonstrating an average 94.25% precision, recall, and F1-score with 96% accuracy for dataset 1, while an average 87.5% precision, recall, and F1-score, with accuracy of 88% for dataset 2. To affirm the robustness of our findings, we perform a comprehensive comparison with existing techniques, revealing that our method consistently outperforms these approaches. By systematically fine-tuning these critical hyperparameters, our model not only enhances its performance but also bolsters its generalization capabilities. This optimized CNN model provides medical experts with a more precise and efficient tool for supporting their decision-making processes in brain tumor diagnosis.

7.
Cureus ; 16(3): e57271, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38686244

ABSTRACT

Endovascular aneurysm repair (EVAR) is a preferred treatment for abdominal aortic aneurysms, though it comes with complications such as endoleaks and graft infections that may necessitate late open conversion (LOC). This systematic review and meta-analysis, drawing on studies from PubMed/MEDLINE, Embase, and the Cochrane Database of Systematic Reviews, aimed to evaluate the incidence, outcomes, and factors leading to LOC after EVAR. The analysis of 11 selected studies revealed a 5.3% incidence of LOC, with a patient cohort predominantly male (79%) and an average age of 73.5 years. The interval between initial EVAR and LOC was 35.1 months on average, with the Excluder device most frequently necessitating LOC. A notable 68% of endovascular salvage attempts before LOC failed. The study highlighted rupture and type I endoleak as the primary reasons for urgent LOC, which exhibited a 10-fold higher mortality rate compared to elective LOC. Elective LOC procedures had a 30-day mortality rate similar to primary elective open aneurysm repairs. These findings underscore the importance of vigilant post-EVAR patient monitoring and suggest that the methodological quality of underlying research should be considered in interpreting these results.

8.
Dent J (Basel) ; 12(4)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38668012

ABSTRACT

OBJECTIVES: A tricalcium silicate-based cement, Biodentine™, has displayed antibiofilm activity when mixed with chitosan powder. This study aimed to assess the effect of chitosan incorporation on the physico-mechanical and biological properties of Biodentine™. METHODS: In this study, medium molecular weight chitosan powder was incorporated into Biodentine™ in varying proportions (2.5 wt%, 5 wt%, 10 wt%, and 20 wt%). The setting time was determined using a Vicat apparatus, solubility was assessed by calculating weight variation after water immersion, radiopacity was evaluated and expressed in millimeters of aluminum, the compressive strength was evaluated using an Instron testing machine, and the microhardness was measured with a Vickers microhardness tester. In addition, surface topography of specimens was analyzed using scanning electron microscopy, and the effect of chitosan on the viability of human embryonic kidney (HEK 293) cells was measured by a colorimetric MTT assay. RESULTS: Incorporation of 2.5 wt% and 5 wt% chitosan powder delivered an advantage by speeding up the setting time of Biodentine material. However, the incorporation of chitosan compromised all other material properties and the crystalline structure in a dose-dependent manner. The chitosan-modified material also showed significant decreases in the proliferation of the HEK 293 cells, signifying decreased biocompatibility. SIGNIFICANCE: Chitosan incorporation into calcium silicate materials adversely affects the physical and biological properties of the material. Despite the increased antimicrobial activity of the modified material, the diminution in these properties is likely to reduce its clinical value.

9.
PeerJ Comput Sci ; 10: e1867, 2024.
Article in English | MEDLINE | ID: mdl-38435590

ABSTRACT

The accurate detection of brain tumors through medical imaging is paramount for precise diagnoses and effective treatment strategies. In this study, we introduce an innovative and robust methodology that capitalizes on the transformative potential of the Swin Transformer architecture for meticulous brain tumor image classification. Our approach handles the classification of brain tumors across four distinct categories: glioma, meningioma, non-tumor, and pituitary, leveraging a dataset comprising 2,870 images. Employing the Swin Transformer architecture, our method intricately integrates a multifaceted pipeline encompassing sophisticated preprocessing, intricate feature extraction mechanisms, and a highly nuanced classification framework. Utilizing 21 matrices for performance evaluation across all four classes, these matrices provide a detailed insight into the model's behavior throughout the learning process, furthermore showcasing a graphical representation of confusion matrix, training and validation loss and accuracy. The standout performance parameter, accuracy, stands at an impressive 97%. This achievement outperforms established models like CNN, DCNN, ViT, and their variants in brain tumor classification. Our methodology's robustness and exceptional accuracy showcase its potential as a pioneering model in this domain, promising substantial advancements in accurate tumor identification and classification, thereby contributing significantly to the landscape of medical image analysis.

10.
Med Sci Monit ; 30: e943706, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38500254

ABSTRACT

BACKGROUND The advent of digital impressions using computer-aided design and manufacturing technology (CAD/CAM) has simplified and improved the fabrication of implant prostheses in dentistry. The conventional impression has several drawbacks, including tray selection, material type, impression technique, impression disinfection, and cast model storage. The inaccuracies caused by distortion and contraction of impression material can be minimized with digital impressions. This study aimed to compare digital dental impressions of 10 working casts made using the Pindex laser removable die system to fabricate parallel drill channels vs 10 working casts made using the Di-Lok plastic tray removable die system. MATERIAL AND METHODS An implant master die with 2 dental implant analogs was fabricated. Ten working casts using the Pindex laser removable die system with parallel drill channels and 10 working casts using the Di-Lok plastic tray removable die system were fabricated. The working casts were scanned using an extra-oral laboratory scanner and the implant master model was scanned with an intra-oral scanner. RESULTS The properties of the casts made using the 2 systems were evaluated and analyzed with ANOVA and post hoc Tukey test. The mean horizontal linear distances between A1B1 (P<0.021), A2B2 (P<0.018), C1D1 (P<0.026), C2D2 (P<0.03), B1C1 (P<0.01), and mean vertical distances between B1A2 (P<0.015), C1D2 (P<0.001), B1B2 (P<0.028), and C1C2 (P<0.001) were significantly different between the Pindex system and Di-Lok tray system as compared to intra-oral scans. CONCLUSIONS Complete digital workflow with intra-oral scans were more than the partial digital workflow with extra-oral scans for the Pindex system and Di-Lok tray systems.


Subject(s)
Dental Implants , Models, Dental , Workflow , Computer-Aided Design , Denture, Partial, Fixed , Research Design
11.
Med Sci Monit ; 30: e943401, 2024 Mar 06.
Article in English | MEDLINE | ID: mdl-38444156

ABSTRACT

BACKGROUND Several auxiliary features have been proposed to achieve sustainable retention for short-prepared dental crowns; however, achieving retention is challenging. This study aimed to assess the impact of increased total occlusal convergence and auxiliary preparation factors like box and groove on the retention form of short tooth preparations. MATERIAL AND METHODS Eighty resin machine-milled dies with a height of 3 mm and a deep chamfer margin of 1 mm were prepared to mimic the short-prepared molar. Initially, 2 teeth were prepared following the guidelines, and the total occlusal convergence was kept at 10° and 20°, respectively. Auxiliary features such as the proximal box and buccal groove were prepared on separate 20° dies. Eighty dies were prepared with 10 samples each for 10°, 20°, 20° with proximal box and 20° with buccal groove for zirconia (n=40) and metal crowns (n=40). Cementation was done with glass ionomer luting cement, and a pull-off test was conducted. Data were analyzed using one-way analysis of variance and post hoc fisher least significant difference test (P<0.05). RESULTS The highest mean was observed in the proximal box group with the metal crown (14.59), and the lowest in the group with 20° zirconia crowns (9.12). Within groups, the highest retentive values were found for the 20° taper with proximal box preparation; the lowest was for the 20° taper group. CONCLUSIONS Within the study limitations, it could be concluded that incorporating a proximal box or buccal groove in short tooth preparations with an increased total occlusal convergence improved retentive values.


Subject(s)
Glass Ionomer Cements , Mouth , Zirconium , Cell Membrane , Crowns
12.
Heliyon ; 10(6): e27594, 2024 Mar 30.
Article in English | MEDLINE | ID: mdl-38509985

ABSTRACT

Individuals who are diagnosed with chronic kidney disease, particularly those receiving maintenance hemodialysis treatment, face a greater likelihood of suffering from severe symptoms and fatality due to COVID-19. This study aimed to explore the optimal vaccination approach for these individuals. The study used data analysis tasks such as data preprocessing, cleaning, and exploration, and machine learning models including linear regression, random forest, XGBoost, gradient boosting, AdaBoost, decision trees, Lasso, and ridge regression were used to construct the predictive model. The study found that the Lasso model performed the best overall in predicting anti-S IgG antibodies levels in response to COVID-19 vaccines for people with kidney failure with MAE of 8.81, RMSE of 19.59, and R2 value of 0.93. The adjusted R2 value for the Lasso model was also 0.93, indicating that the model's ability to explain the variance in the data was not affected by the number of predictors in the model. The Random Forest model best predicted the duration of immunogenicity, with R2 and adjusted R2 values of 0.71 and 0.69, respectively. The ensemble model that includes all eight models, i.e., Ridge, Lasso, Linear Regression, Random Forest, AdaBoost, Gradient Boosting, XGBoost, and Decision Tree, has the best performance with the lowest MAE, the lowest RMSE, the highest R2, and the highest adjusted R2 values of 3.91, 5.00, 0.73, and 0.72, respectively. However, further research is required to validate these models and extend their application to different populations and vaccine types, as well as considering other factors that may affect immune response to COVID-19 vaccines. These findings can be helpful in improving vaccination strategies and promoting public health.

13.
Curr Med Imaging ; 20: 1-17, 2024.
Article in English | MEDLINE | ID: mdl-38389382

ABSTRACT

BACKGROUND: Segmenting tumors in MRI scans is a difficult and time-consuming task for radiologists. This is because tumors come in different shapes, sizes, and textures, making them hard to identify visually. OBJECTIVE: This study proposes a new method called the enhanced regularized ensemble encoder-decoder network (EREEDN) for more accurate brain tumor segmentation. METHODS: The EREEDN model first preprocesses the MRI data by normalizing the intensity levels. It then uses a series of autoencoder networks to segment the tumor. These autoencoder networks are trained using back-propagation and gradient descent. To prevent overfitting, the EREEDN model also uses L2 regularization and dropout mechanisms. RESULTS: The EREEDN model was evaluated on the BraTS 2020 dataset. It achieved high performance on various metrics, including accuracy, sensitivity, specificity, and dice coefficient score. The EREEDN model outperformed other methods on the BraTS 2020 dataset. CONCLUSION: The EREEDN model is a promising new method for brain tumor segmentation. It is more accurate and efficient than previous methods. Future studies will focus on improving the performance of the EREEDN model on complex tumors.


Subject(s)
Brain Neoplasms , Neural Networks, Computer , Humans , Algorithms , Image Processing, Computer-Assisted/methods , Brain Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods
14.
Int J Stroke ; : 17474930241237120, 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38395748

ABSTRACT

BACKGROUND: Following transient ischemic attack (TIA) and minor stroke, the risk of recurrent stroke can be significantly reduced with short-duration dual antiplatelet therapy (DAPT). We wish to investigate whether 10 days of DAPT is as effective as 21 days' treatment. STUDY DESIGN: This is an open-label, randomized, parallel-group study comparing whether 10 days of DAPT treatment (ASA + clopidogrel) is non-inferior to 21 days of DAPT in patients with acute ischemic stroke (AIS) or high-risk TIA. In both groups, DAPT is started within 24 hours of symptom onset. This study is being conducted in approximately 15 study sites in the Kingdom of Saudi Arabia. The planned sample size is 1932. OUTCOMES: Non-inferiority of 10 days compared to 21 days of DAPT in the prevention of the composite endpoint of stroke and death at 90 days in AIS/TIA patients. The primary safety outcome is major intra-cranial and systemic hemorrhage. STUDY PERIOD: Enrolment started in the second quarter of 2023, and the completion of the study is expected in the fourth quarter of 2025. DISCUSSION: The trial is expected to show that 10 days of DAPT is non-inferior for the prevention of early recurrence of vascular events in patients with high-risk TIAs and minor strokes.

15.
Cureus ; 16(1): e52285, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38357088

ABSTRACT

Hemangiomas are benign vascular tumors and are classified into cavernous, capillary, and mixed, with the head and neck area as the most common site. Hemangiomas are common in pediatrics and rare in adults. Diagnosing cavernous hemangioma is challenging and requires a complete history, proper physical examination, and several radiological modalities to improve diagnostic accuracy because it is uncommon in adults. Herein, we present a case of a 66-year-old female Saudi patient with cavernous hemangioma from the diagnosis until the surgical treatment. No previous studies are reported in Saudi Arabia and this is a rare presentation of cavernous hemangioma at this age. Cavernous hemangioma in the parotid gland in adults is uncommon and is difficult to diagnose. Therefore, a thorough physical examination and several radiological modalities are required to improve diagnostic accuracy. The most effective treatment of cavernous hemangioma in adults is surgical resection.

16.
Toxics ; 12(1)2024 Jan 13.
Article in English | MEDLINE | ID: mdl-38251022

ABSTRACT

Three-dimensional (3D) printer usage in household and school settings has raised health concerns regarding chemical and particle emission exposures during operation. Although the composition of 3D printer emissions varies depending on printer settings and materials, little is known about the impact that emissions from different filament types may have on respiratory health and underlying cellular mechanisms. In this study, we used an in vitro exposure chamber system to deliver emissions from two popular 3D-printing filament types, acrylonitrile butadiene styrene (ABS) and polylactic acid (PLA), directly to human small airway epithelial cells (SAEC) cultured in an air-liquid interface during 3D printer operation. Using a scanning mobility particle sizer (SMPS) and an optical particle sizer (OPS), we monitored 3D printer particulate matter (PM) emissions in terms of their particle size distribution, concentrations, and calculated deposited doses. Elemental composition of ABS and PLA emissions was assessed using scanning electron microscopy coupled with energy dispersive X-ray spectroscopy (SEM-EDX). Finally, we compared the effects of emission exposure on cell viability, inflammation, and metabolism in SAEC. Our results reveal that, although ABS filaments emitted a higher total concentration of particles and PLA filaments emitted a higher concentration of smaller particles, SAEC were exposed to similar deposited doses of particles for each filament type. Conversely, ABS and PLA emissions had distinct elemental compositions, which were likely responsible for differential effects on SAEC viability, oxidative stress, release of inflammatory mediators, and changes in cellular metabolism. Specifically, while ABS- and PLA-emitted particles both reduced cellular viability and total glutathione levels in SAEC, ABS emissions had a significantly greater effect on glutathione relative to PLA emissions. Additionally, pro-inflammatory cytokines including IL-1ß, MMP-9, and RANTES were significantly increased due to ABS emissions exposure. While IL-6 and IL-8 were stimulated in both exposure scenarios, VEGF was exclusively increased due to PLA emissions exposures. Notably, ABS emissions induced metabolic perturbation on amino acids and energy metabolism, as well as redox-regulated pathways including arginine, methionine, cysteine, and vitamin B3 metabolism, whereas PLA emissions exposures caused fatty acid and carnitine dysregulation. Taken together, these results advance our mechanistic understanding of 3D-printer-emissions-induced respiratory toxicity and highlight the role that filament emission properties may play in mediating different respiratory outcomes.

17.
PLoS One ; 19(1): e0281208, 2024.
Article in English | MEDLINE | ID: mdl-38232095

ABSTRACT

BACKGROUND: Early identification of a patient with infection who may develop sepsis is of utmost importance. Unfortunately, this remains elusive because no single clinical measure or test can reflect complex pathophysiological changes in patients with sepsis. However, multiple clinical and laboratory parameters indicate impending sepsis and organ dysfunction. Screening tools using these parameters can help identify the condition, such as SIRS, quick SOFA (qSOFA), National Early Warning Score (NEWS), or Modified Early Warning Score (MEWS). We aim to externally validate qSOFA, SIRS, and NEWS/NEWS2/MEWS for in-hospital mortality among adult patients with suspected infection who presenting to the emergency department. METHODS AND ANALYSIS: PASSEM study is an international prospective external validation cohort study. For 9 months, each participating center will recruit consecutive adult patients who visited the emergency departments with suspected infection and are planned for hospitalization. We will collect patients' demographics, vital signs measured in the triage, initial white blood cell count, and variables required to calculate Charlson Comorbidities Index; and follow patients for 90 days since their inclusion in the study. The primary outcome will be 30-days in-hospital mortality. The secondary outcome will be intensive care unit (ICU) admission, prolonged stay in the ICU (i.e., ≥72 hours), and 30- as well as 90-days all-cause mortality. The study started in December 2021 and planned to enroll 2851 patients to reach 200 in-hospital death. The sample size is adaptive and will be adjusted based on prespecified consecutive interim analyses. DISCUSSION: PASSEM study will be the first international multicenter prospective cohort study that designated to externally validate qSOFA score, SIRS criteria, and EWSs for in-hospital mortality among adult patients with suspected infection presenting to the ED in the Middle East region. STUDY REGISTRATION: The study is registered at ClinicalTrials.gov (NCT05172479).


Subject(s)
Sepsis , Systemic Inflammatory Response Syndrome , Adult , Humans , Cohort Studies , Emergency Service, Hospital , Hospital Mortality , Multicenter Studies as Topic , Organ Dysfunction Scores , Prognosis , Prospective Studies , Retrospective Studies , ROC Curve , Sepsis/diagnosis
19.
Pediatr Neonatol ; 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38218717

ABSTRACT

BACKGROUND: Meropenem is a widely used carbapenem for treating severe pediatric infections. However, few studies have assessed its pharmacokinetics/pharmacodynamics (PK/PD) in pediatric patients. This study aimed to evaluate the proportion of Saudi pediatric patients achieving the PK/PD target of meropenem. METHODS: A prospective observational study was conducted at King Saud University Medical City from July to September 2022. Pediatric patients receiving meropenem for suspected or proven infections were included in the study. The primary outcome was the percentage of patients achieving the recommended PK/PD target for critically ill or non-critically ill pediatric patients. RESULTS: The study included 30 patients (nine neonates and 21 older pediatric patients). All neonates were critically ill. Among them, 55 % achieved the PK/PD target of 100 % free time above the MIC. In older ICU pediatric patients, only 11 % attained this target, whereas 58 % of older pediatrics in the general wards achieved the PK/PD target of 50 % free time above the MIC. Augmented renal clearance (ARC) was identified in 57 % of our pediatric patient population, none of whom achieved the recommended PK/PD targets. The median trough concentrations in patients with and without ARC were 0.75 and 1.3 µg/mL, respectively (P < 0.05). CONCLUSIONS: The majority of patients in our cohort did not achieve the PK/PD target for meropenem. ARC emerged as a major risk factor for target attainment failure in both critically ill and non-critically ill pediatric patients.

20.
Med Sci Monit ; 29: e941654, 2023 Nov 04.
Article in English | MEDLINE | ID: mdl-37924203

ABSTRACT

BACKGROUND The aim of this study was to assess and compare the vertical/horizontal dimensions and occlusal accuracy of non-working/opposing casts obtained from three different impression materials and 3D print cast. MATERIAL AND METHODS Dentulous Master models simulating a case of a fixed dental prosthesis were mounted on an articulator (control group). Opposing mandibular casts obtained from three different impression materialsand 3-dimensional print constituted test groups , ,and , respectively. Three points, anterior vertical (AV), posterior vertical (PV), and anteroposterior (AP) were compared for dimensional accuracy among casts. Occlusal accuracy was analyzed on Medit Link software at 3 teeth (#13, #17, and #27). After calculating means for each group, the differences were calculated at probability value of P≤0.05 using the single-sample t test, ANOVA, and Tukey test. RESULTS The dimensions were significantly different from those of the mounted master models except in Gp AL(E) and Gp AL(F) at AV dimension and Gp AL(E) at AP dimension (P>0.05). A statistically significant difference of the error of means among the 4 tested groupswere detected only at 2 dimensions (AV and PV) between the Gp AL(E) and Gp 3D-C and between Gp AL(F) and Gp 3D-C groups. Other groups showed no significant differences. CONCLUSIONS The opposing casts obtained from the extended-pour alginate and alginate alternative impression materials showed higher occlusal accuracy compared to conventional alginate and 3D printed casts.


Subject(s)
Models, Dental , Printing, Three-Dimensional , Humans , Alginates , Mandible , Software
SELECTION OF CITATIONS
SEARCH DETAIL
...