1.
Med Eng Phys ; 48: 188-195, 2017 10.
Article in English | MEDLINE | ID: mdl-28709931

ABSTRACT

Total hip replacement is aimed at relieving pain and restoring function. Currently, imaging techniques are primarily used as a clinical diagnosis and follow-up method. However, these are unreliable for detecting early loosening, and this has led to the proposal of novel techniques such as vibrometry. The present study had two aims, namely, the validation of the outcomes of a previous work related to loosening detection, and the provision of a more realistic anatomical representation of the clinical scenario. The acetabular cup loosening conditions (secure, and 1 and 2 mm spherical loosening) considered were simulated using Sawbones composite bones. The excitation signal was introduced in the femoral lateral condyle region using a frequency range of 100-1500 Hz. Both the 1 and 2 mm spherical loosening conditions were successfully distinguished from the secure condition, with a favourable frequency range of 500-1500 Hz. The results of this study represent a key advance on previous research into vibrometric detection of acetabular loosening using geometrically realistic model, and demonstrate the clinical potential of this technique.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Equipment Failure Analysis/methods , Vibration , Accelerometry , Acetabulum/diagnostic imaging , Ultrasonography
2.
Med Eng Phys ; 37(8): 739-45, 2015 Aug.
Article in English | MEDLINE | ID: mdl-26054805

ABSTRACT

Current techniques for diagnosing early loosening of a total hip replacement (THR) are ineffective, especially for the acetabular component. Accordingly, new, accurate, and quantifiable methods are required. The aim of this study was to investigate the viability of vibrational analysis for accurately detecting acetabular component loosening. A simplified acetabular model was constructed using a Sawbones(®) foam block. By placing a thin silicone layer between the acetabular component and the Sawbones block, 2- and 4-mm soft tissue membranes were simulated representing different loosening scenarios. A constant amplitude sinusoidal excitation with a sweep range of 100-1500 Hz was used. Output vibration from the model was measured using an accelerometer and an ultrasound probe. Loosening was determined from output signal features such as the number and relative strength of observed harmonic frequencies. Both measurement methods were sufficient to measure the output vibration. Vibrational analysis reliably detected loosening corresponding to both 2 and 4 mm tissue membranes at driving frequencies between 100 and 1000 Hz (p < 0.01) using the accelerometer. In contrast, ultrasound detected 2-mm loosening at a frequency range of 850-1050 Hz (p < 0.01) and 4-mm loosening at 500-950 Hz (p < 0.01).


Subject(s)
Accelerometry/methods , Equipment Failure Analysis/methods , Hip Joint/diagnostic imaging , Hip Joint/surgery , Hip Prosthesis , Prosthesis Failure , Arthroplasty, Replacement, Hip , Humans , Models, Biological , Spectrum Analysis , Ultrasonography , Vibration