1.
Clin Neuroradiol ; 29(2): 295-301, 2019 Jun.
Article in English | MEDLINE | ID: mdl-29318353

ABSTRACT

BACKGROUND AND PURPOSE: The Barrel device is an electrolytically detachable laser cut, closed-cell microstent that is used for neck reconstruction in wide-necked bifurcation and branching aneurysms to support coiling. The key feature is a barrel section that herniates over the aneurysmal ostium. The objective was to evaluate the safety, feasibility and the immediate and mid-term occlusion results of this new device. MATERIAL AND METHODS: The databases of two tertiary care centers were screened for all Barrel-based stent-assisted intracranial coil embolization of wide-necked aneurysms between June 2015 and September 2016. Case files and imaging data were retrospectively analyzed for angiographic and clinical outcome parameters, including immediate and mid-term modified Raymond-Roy aneurysm occlusion classification (RROC) rates and procedural complications. RESULTS: A total of 21 patients comprising 21 intracranial aneurysms (20 unruptured, 1 ruptured) were treated with the Barrel device and additional coiling of the aneurysm sac. All aneurysms were wide-necked, saccular bifurcation aneurysms defined by a dome/neck ratio ≤2. Immediate complete occlusion (RROC1) was observed in 19/21 (90%). An intra-interventional in-stent thrombus formation in two cases (10%) was medically resolved without neurological sequelae. A single case of symptomatic in-stent stenosis (5%) was cleared by balloon angioplasty. Follow-up (FU) was available in 20/21 cases (95%) after a median of 282 days (range: 17-591 days). At follow-up 19/20 aneurysms (95%) were completely occluded (RROC1). CONCLUSION: The Barrel device showed a satisfactory safety profile and a promising rate of immediate and mid-term complete aneurysm occlusion for stent-assisted coil embolization of wide-necked intracranial bifurcation aneurysms, warranting further investigation of the device.


Subject(s)
Embolization, Therapeutic/instrumentation , Intracranial Aneurysm/therapy , Stents , Adult , Aged , Aged, 80 and over , Angiography, Digital Subtraction , Endovascular Procedures , Feasibility Studies , Female , Follow-Up Studies , Humans , Intracranial Aneurysm/drug therapy , Magnetic Resonance Angiography , Male , Middle Aged , Models, Biological , Patient Safety , Platelet Aggregation Inhibitors/therapeutic use , Prosthesis Design , Retrospective Studies , Tertiary Care Centers
SELECTION OF CITATIONS
SEARCH DETAIL
...