1.
Int J Cardiol ; 74(2-3): 107-13, 2000 Jul 31.
Article in English | MEDLINE | ID: mdl-10962109

ABSTRACT

Dobutamine stress echocardiography is widely used to predict reversible left ventricular dysfunction, but evaluation with this method is subjective. Pulsed-wave tissue Doppler imaging is a new technique that allows to obtain quantitative data on wall motion velocities of different myocardial segments through sample-volume placement. Therefore, this tool in combination with DSE may be suitable for identifying viability in asynergic myocardium. To evaluate this, in 40 patients (mean age 57+/-9) with resting dyssynergy (akinesis in 52, hypokinesis in 30) baseline wall motion scores and tissue Doppler variables were collected before and after 5 min infusion of 10 microg/kg per min dobutamine. Forty-six of 82 segments were classified as viable (a reduction in segmental score of at least one grade) according to follow-up echocardiography that was performed 4 weeks after revascularization. While myocardial S velocity percent increase in viable segments was 45+/-10, the increase was 25+/-12 in necrotic segments (n=36) during 10 microg dobutamine infusion (P=0.0001). Assuming 35% as a cut-off for viability the increase in S velocities by DSE yielded an 89% sensitivity and 86% specificity for predicting post-revascularization functional recovery. In conclusion, pulsed-wave tissue Doppler imaging of asynergic myocardium during dobutamine stress echocardiography can identify the viability quantitatively.


Subject(s)
Cardiotonic Agents , Coronary Disease/diagnostic imaging , Dobutamine , Echocardiography, Doppler/methods , Exercise Test/methods , Ventricular Dysfunction, Left/diagnostic imaging , Adult , Aged , Coronary Angiography , Coronary Disease/therapy , Dose-Response Relationship, Drug , Hemodynamics/physiology , Humans , Middle Aged , Myocardial Contraction/drug effects , Myocardial Revascularization , Predictive Value of Tests , Preoperative Care , Reproducibility of Results , Sensitivity and Specificity
2.
Jpn Heart J ; 41(2): 141-52, 2000 Mar.
Article in English | MEDLINE | ID: mdl-10850530

ABSTRACT

False positive inferior wall perfusion defects restrict the accuracy of SPECT in diagnosis of coronary artery disease (CAD). Pulse-Wave Tissue Doppler (PWTD) has been recently proposed to assess regional wall motion velocities. The objectives of this study were to evaluate the presence of CAD by using PWTD during dobutamine stress echocardiography (DSE) in patients with an inferior perfusion defect detected by SPECT and compare PWTD parameters of normal cases with patients who had inferior perfusion defect and CAD. Sixty-five patients (mean age 58 +/- 8 years, 30 men) with a normal LV systolic function at rest according to echocardiographic evaluation with an inferior ischemia determined by SPECT and a control group (CG) of 34 normal cases (mean age 56 +/- 7 years, 16 men) were included in this study. All patients underwent a standard DSE (up to 40 microg / kg / min with additional atropine during sub-maximum heart rate responses). Pulse-wave Doppler tissue sampling of inferior wall was performed in the apical 2-chamber view at rest and stress. The coronary angiography was performed within 24 hours. The results were evaluated for the prediction of significant right coronary artery (RCA) and / or left circumflex coronary artery (CX) with narrowing (> or = 50% diameter stenosis, assessed by quantitative coronary angiography). It was observed that the peak stress mean E / A ratio was lower in patients with CAD when compared to patients without CAD (0.78 +/- 0.2 versus 1.29 +/- 0.11 p < 0.0001). Also the peak stress E / A ratio of normal cases was significantly higher than patients who had CAD (1.19 +/- 0.3 versus 0.78 +/- 0.2 p < 0.0001). When the cut off point for the E / A ratio was determined as 1, the sensitivity and specificity of dobutamine stress PWTD E / A were 89% and 86 %, respectively. The peak stress E / A ratio was higher than 1 in all patients with a false positive perfusion defect. Systolic S velocity increase during DSE was significantly lower in patients with CAD (54 % +/- 17 versus 99 % +/- 24 p = 0.01). The analysis of S velocity increase yielded 81% sensitivity and 76 % specificity for prediction of CAD when a 70 % increase was accepted as a cut-off value. Pulse-wave Doppler tissue sampling during DSE may help to identify false positive inferior wall defects detected by SPECT.


Subject(s)
Cardiotonic Agents , Coronary Circulation , Dobutamine , Echocardiography , Myocardial Ischemia/diagnosis , Specimen Handling/methods , Aged , Exercise Test , False Positive Reactions , Female , Humans , Male , Middle Aged , Myocardial Ischemia/physiopathology , Reference Values , Stress, Mechanical , Tomography, Emission-Computed, Single-Photon